NAVIS WL12/D Bedienungsanleitung

WL12/D DISPLAY UNIT
MANUAL
Model: WL12/D
PREFACE
Thank you for buying Navis anemometer. This manual provides information for the best performance and safe application of the
anemometer display unit. This manual does not cover the anemometer sensors for which the manuals will come separately.
Read this manual carefully before starting the installation. Keep this manual after installation for future reference.
INTRODUCTION
WL12/D is long range receiver/display unit which receive data from NAVIS wind sensor, displays various wind data and store them on
micro SD card. It can be powered by batteries or by micro USB adapter (not enclosed). Built-in battery back-up ensure that the set time
is not reset in case of power interruptions or when unit is switched off.
3.
1. 1. Display
4. 2. SMA antenna connector
2. 3. Signal light
4. Keys
5. SD card insertion
6. USB power supply
6. 5.
Figure 1. (WL12/D –front panel)
WL12/D is compatible with NAVIS wind sensors: WS 010-1 (wind speed sensor, standard range), WS 011-1 (wind speed sensor,
extended range), WSD 010-1 (wind speed/direction sensor, standard range), WSD 011-1 (wind speed/direction sensor, extended range).
MOUNTING
Select the position where the signal reception is strong enough under all conditions.
There are two holes on back panel of display unit intended for wall mounting (screws are not included).
Display unit can be mounted to the ferrous surface with mounting magnets (optional accessories).
ANTENNA CONNECTION
Connect antenna to SMA connector on display unit only when power supply is switched OFF.
OPERATION
Display unit receives wind and temperature data from sensor, calculates average values and stores them to the memory card. Current
data received from sensor, as well as part of the wind speed history are presented on LCD display. Detailed data in selected interval
are stored on SD card.
All operating parameters can be set using three keys on the receiver unit.
If the display unit is delivered as set, with sensor included, the correct sensor address is already set.
Otherwise please set first the correspondent sensor address. Check the address settings procedure in chapter “SETTINGS”.
Fresh wind data from active sensor are received every two seconds. If data are not received for more than 20 seconds,
“No data” appears on the display.
SWITCHING ON
Hold pressed the F key for more than 3 seconds for switch ON the unit.
SWITCHING OFF
In the setting menu select “Yes” and confirm to power OFF the unit. Real time clock will continue, graphs will reset and data on SD
card will remain.

DISPLAY
With short presses of Fkey you can switch between pages to see various data history. 7. 6.
5.
1st page (Figure 4):
1. Current wind speed
2. Current temperature
3. Current wind direction 1. 4.
4. Current date and time
5. SD card insertion indicator
6. Empty battery state indicator
(it appears if battery replacement is needed) 2. 3.
7. Signal strength value (in dB)
Figure 4. (Display –1st page)
2nd page (Figure 3):
7 days history of average and maximum wind speed
3rd page (Figure 4):
24 h graph of average wind speed
Each column present average wind speed during 1 hour
Figure 3. (Display –2st page) Figure 4. (Display –3st page)
4rd page (Figure 5):
24 h graph of average wind direction
Each column present average wind direction during 1 hour
5th page (Figure 6):
24 h graph of average temperature
Each column present average temperature during 1 hour Figure 5. (Display –4st page) Figure 6. (Display –5st page)
DISPLAY ILLUMINATION
Shortly press key with light icon to switch ON and OFF the display illumination
DISPLAY AUTO OFF
Activate this mode in the setting menu to prolong battery life. Using this mode, the display switches OFF after 2 minutes of inactivity.
All other functions stay active. Display switches ON with each press of the key.
Also in display OFF state the LED signalize data reception.
SIGNAL RECEPTION
Reed LED blinks when the display unit receives a signal from the sensor (every 2 seconds if reception is good).
Signal strength is numerically shown in dB:
•-105 dB is approximately the limit where display unit stops receiving
• -100 dB and lower means very week signal
• -95 ... -90 dB is considered as still acceptable
• -85 dB and higher is a good signal
When the sensor doesn't send data (in OFF state) or when the signal is lost for a more than 20 seconds, the “dashes” appears on the
display, indicating that the receiver doesn’t receive data from the sensor (sensor OFF or out of range).
RANGE
Connection between sensor and display unit works on free 868 MHz band. Reach is up to 300 meters (1000 meters with extended
range sensor and longer antenna) - at 10 m sensor mounting height and when there is no obstacle between the sensor and the display
unit. Inside buildings the range is much shorter. Normally the signal can be received through two to three walls.
POWER SUPPLY
Unit can be battery or external powered, via micro USB connector. Built in Lithium 3 V battery ensures real time clock even in case of
power interruption or during battery changing.
BATTERY REPLACEMENT
Double blinks of LED diode marks that either - the sensor or the receiver battery should be changed.
Battery icon on LCD indicates the empty state of receiver batteries.
Alternating sign “S” with battery icon on LCD indicates the empty state of sensor battery.
Battery replacement of display unit:
Unscrew all 4 screws on backside of display unit enclosure and remove the back panel. Replace the batteries for display unit operation
(4 x 1,5V AA Alkaline) or for display unit real time clock battery back-up (1 x 3 V CR2032).
Place the rear panel of display unit in position and tighten 4 screws.
RESET OF DISPLAY UNIT
With middle button pressed while inserting batteries in display unit –RESET is performed (all settings except »Sensor Address« and
»Calibration factors« goes to default values).

SETTINGS
1. Hold pressed the F key to enter the setting menu.
2. By up and down keys select the parameter you wish to adjust and press F key to enter into selected parameter. The adjustable
parameter blinks.
3. By up and down key adjust the parameter value. Press F to enter new value and move to next parameter.
4. Exiting setting menu: hold pressed the F key to move back for one level.
Anemometer also returns to normal operation after 2 minutes of inactivity.
PARAMETERS
Parameter:
Description of parameter:
TURN OFF: No/Yes
Powering off the display unit - select Yes and confirm to switch off
Time: 01:58
Time setting - 24 h time format
Date: 01/01/2018
Date setting - day/month/year
Day: Monday
Day setting
Sensor Address: XX
Set the address of receiving sensor
Scan for sensors
Get list of all available nearby sensors
Logging int: 1 min
Logging interval (10 s, 1 min, 10 min or 60 min)
WS unit: m/s
Wind speed unit (m/s, km/h, knots, mph)
Temperature unit: 0C
Temperature unit (0 C or 0 F)
WS Cal. Factor: 0.0%
Calibration factor for wind speed (-15,0 ...+15,0 %, in 0,5 % steps)
WD Cal.: 00
Calibration of wind direction (-180 0...+180 0, in 1 0steps)
Temp. Cal.: 00
Calibration of temperature (-2.0 0...+2.0 0, in 0,5 0steps)
Display Auto Off: No
Automatic display switching off (saving mode/ reducing power consumption)
Yes: display automatically switches off after 2 minutes
No: display is always ON
Reset Data: No
No/Yes
Language: English
English / French
WL12 vXXXXXX
Software version
STORING TO SD CARD
Data in .txt format are stored to SD card every full hour. Each data has date and time stamp.
Logging interval is selectable from 10 sec to 1h. Data are stored in the .txt format and are suitable for processing in programs for
working whit spreadsheet (Excel, Open office, etc...).
Mark “NA” in logged data present missed wind data for marked interval.
Mark “nW” in logged wind direction data present undefined wind direction caused of no wind speed.
There is a rare possibility that individual logged packets could be corrupt due to external causes.
It is recommended to eliminate them during processing logged data.
For each using of new type SD card it is recommended to test writing data to SD card.
STORE DATA FROM SD CARD
It is recommended to store data from SD card every month for preventing data loss because of empty battery in receiver or other
external factors.
DESCRIPTION OF DATA STORED ON SD CARD
[WS]: average wind speed in selected units and logging interval
[WSm]: maximum wind speed in selected units and logging interval
[WSt]: average temperature in selected units and selected logging interval
[WD]: average wind direction in selected logging interval
[RSSI]: average signal strength in selected logging interval
[dd/mm/yyyy]: day/month/year of created logged data
[hh:mm:ss]: hours:minutes:seconds of created logged data
EXAMPLE OF DATA STORED ON SD CARD
Example of logged first 10 wind data from WSD sensor in 10s logging interval. Average [WS] and maximum [WSm] wind speed data
are in units of m/s, temperature in degrees of Celsius [WSt], wind direction [WD] in degrees and signal strength [RSSI] in dB.
<------Navis Elektronika WL12 v270318------->
<------------------------------------------->
<Logging Interval:10s----------------------->
<WS[m/s]-WSm[m/s]-WSt[C]-WD[deg]-RSSI[-dB]-->
<n/a[Data not available] nW[No wind present]>
dd/mm/yyyy,hh:mm:ss, WS, WSm, WSt, WD, RSSI
17/10/2016,00:00:10, 0.9, 0.9, 7,184, 65
17/10/2016,00:00:20, 0.8, 0.9, 7,190, 63
17/10/2016,00:00:30, 0.9, 0.9, 7,187, 65
17/10/2016,00:00:40, 0.8, 0.8, 7,189, 66
17/10/2016,00:00:50, 0.7, 0.8, 7,185, 64
17/10/2016,00:01:00, 0.7, 0.7, 7,190, 64
17/10/2016,00:01:10, 0.6, 0.7, 7,184, 65
17/10/2016,00:01:20, 0.0, 0.0, 7, nW, 63
17/10/2016,00:01:30, 0.6, 0.7, 7,186, 63
17/10/2016,00:01:40, 0.6, 0.7, 7,189, 65

TROUBLESHOOTING
Symptom
Action
The receiver/display unit cannot read
the sensor
(“dashes”appears on the display)
- check if correct sensor address is set on the display unit
- check if the sensor is not in sleep mode (turn the cups to wake up the sensor)
- check the sensor battery –replace the battery if needed
- check the operation at a reduced distance to the display/receiver
Interrupting and weak sensor signal
- check for obstructions between sensor and display/receiver unit
- place the sensor or display/receiver on a different position with better signal
reception
- reduce distance to the display/receiver
- change the antenna type at display/receiver unit
Unresponsive display unit
- check the batteries of display unit –replace the batteries if needed
- remove 4 x 1,5 V AA Alkaline and 1 x 3 V CR2032 Lithium batteries for 1 minute to
reset display unit.
Clock and date set to default value
- check the battery for real time clock battery back-up (1 x 3 V CR2032) - replace if
needed
TECHNICAL DATA
Wind speed measurement range: 0,6 - 50,0 m/s
Wind direction measurement range: 0 0- 359 0
Temperature measurement range: -30....+60 0 C
Wind speed units: m/s, km/h, knots, mph
Temperature units: 0 C, 0 F
Wind speed resolution: 0,1 m/s
Wind direction resolution: 1 0
Temperature resolution: 1 0 C
Wind speed accuracy: typ. +/- 2,5 %
Wind direction accuracy: +/- 2,5 0
Temperature accuracy: +/- 1 0 C
Logging interval: selectable 10 s, 1 min, 10 min, 60 min
File creation on SD card: creates new file every day at 10 s logging interval
create new file every month at 1 min, 10 min, 60 min logging interval
create new file after each insertion of SD card
create new file after each settings changes
Data format: .txt
Memory card: micro SD formatted in FAT or FAT32 (recommended). Micro SD included.
Power supply: battery or external micro USB adapter 5V DC (not enclosed)
Battery: 4 x 1,5 V AA Alkaline (not included)
1 x 3 V CR2032 Lithium (included, pre-inserted)
Battery life: up to 12 months with display auto off mode
Operating Range:
- sets WL12/WS, WL12/WSD up to 300 m visible distance
- sets WL12X/WS, WL12X/WSD up to 1000 m visible distance
- with Yagi antenna connected 3-4 x nominal range
Operating Frequency: 868 MHz
Antenna input: 50 Ohm, SMA connector
Measuring rate: every 2 sec
Temperature operating range: -30 ... +60 o C
Material: ABS
Dimensions: 125 x 85 x 35 mm
Weight: 150g
Alternations in specifications are subject to change without notice.
ACCESSORIES (optional)
1 SMA antenna (longer type)
2 External antenna with 3 m cable, magnetic mounting
3 YAGI antenna
4 Spare micro SD card
5 USB / micro SD adapter
6 External power adapter
7 MDMA/WL12 Magnetic display mounting assembly 1 2 3 4 5 6
WARRANTY (LIMITED)
The warranty period of NAVIS products is one year after the date of purchase. During limited warranty period any defective
product will be repaired or replaced with comparable product without charges. The claimed product will be repaired or replaced
only when returned to the store where it was purchased together with original invoice. Failure to follow these instructions may
invalidate the warranty. The limited warranty does not cover battery and damages of any kind including physical damages caused
accidentally or misuse of the product. NAVIS does not accept responsibility for any problems which may arise from applications
other than the product was designed for. Any liability for direct or indirect damage caused by product failure is excluded.
180120