Nordmann RC4 Bedienungsanleitung

2549079 EN 1011
Nordmann RC4/DC4
MOUNTING INSTRUCTIONS
Electrode Humidifiers
NORDMANN
ENGINEERING
NORDMANN
ENGINEERING
Dampfluftbefeuchter econoVap


3
Contents
1 Introduction 4
1.1 To the very beginning 4
1.2 Notes on the mounting instructions 4
2 For your safety 6
3 Product Overview 8
3.1 Models overview 8
3.2 Identicationoftheunit 8
3.3 Steamhumidierconstruction 9
3.4 Functionaldescription 11
3.5 Humidicationsystemoverview 12
3.6 Options 14
3.7 Accessories 14
3.7.1 Accessories overview 14
3.7.2 Accessorydetails 15
3.8 Standarddelivery 16
3.9 Storing/Transportation/Packaging 16
4 Notes for the planning engineer 17
4.1 Selecting the unit version 17
4.1.1 Selecting the unit 17
4.1.2 Calculatingthemaximumrequiredsteamcapacity 18
4.2 Selectingtheoptionsanaccessories 18
4.3 Selecting the control system 19
5 Mounting and installation work 21
5.1 Importantnotesformountingandinstallationwork 21
5.2 Mounting the unit 22
5.2.1 Notesonlocatingandmountingtheunit 22
5.2.2 Mountingthehumidier 24
5.2.3 Inspectingtheinstalledunit 25
5.3 Steaminstallation 26
5.3.1 Overviewsteaminstallation 26
5.3.2 Positioningandmountingofthesteamdistributionpipe 27
5.3.3 Installingthesteamdistributors 29
5.3.4 Installingthesteamhose 30
5.3.5 Installingthecondensatehose 31
5.3.6 Inspectingthesteaminstallation 32
5.4 Waterinstallation 33
5.4.1 Overviewwaterinstallation 33
5.4.2 Notesonwaterinstallation 33
5.4.3 Inspectingthewaterinstallation 34
5.5 Electricinstallation 35
5.5.1 WiringdiagramNordmannRC4/DC4 35
5.5.2 Notesonelectricinstallation 36
5.5.3 InsertingtheCFcard 38
5.5.4 Inspectingtheelectricalinstallation 38
6 Productspecications 39
6.1 Technicaldata 39
6.2 Unit dimensions 40
6.3 Declarationofconformity 41

4
Limitation
ThesubjectofthesemountinginstructionsisthesteamhumidierNordmannRC4/DC4 in
its different versions. The various accessories are only describedinsofar as this is necessary
forproperoperationoftheequipment.Furtherinformationonaccessoriescanbeobtainedinthe
respectiveinstructions.
These mounting instructions is restricted to the installation ofthesteamhumidierNordmannRC4/
DC4andismeantforwelltrainedpersonnelbeingsufcientlyqualiedfortheirrespective
work.
Themountinginstructionsaresupplementedbyvariousseparateitemsofdocumentation(operating
instructions,sparepartslist,manualsforaccessories,etc.).Wherenecessary,appropriatecross-
referencesaremadetothesepublicationsinthemountinginstructions.
1 Introduction
WethankyouforhavingpurchasedthesteamhumidierNordmannRC4/DC4.
ThesteamhumidierNordmannRC4/DC4incorporatesthelatesttechnicaladvancesandmeetsall
recognizedsafetystandards.Nevertheless,improperuseoftheNordmannRC4/DC4mayresultin
dangertotheuserorthirdpartiesand/orimpairmentofmaterialassets.
Toensureasafe,proper,andeconomicaloperationofthesteamhumidierNordmannRC4/DC4,
please observe and comply with all information and safety instructions contained in the present
manualaswellastheinstructionsgiveninthemanualsforthecomponentsusedinthehumidica-
tion system.
Ifyouhavequestions,whicharenotorinsufcientlyansweredinthisdocumentation,pleasecontact
yourNordmannsupplier.Theywillbegladtoassistyou.
1.2 Notes on the mounting instructions
1.1 To the very beginning

5
Symbols used in this manual
CAUTION!
Thecatchword“CAUTION”designatesnotesinthisdocumentationthat,ifneglected,maycause
damage and/or malfunction of the unit or other material assets.
WARNING!
Thecatchword“WARNING”usedinconjunctionwiththegeneralcautionsymboldesignatessafety
anddangernotesinthisdocumentationthat,ifneglected,maycausetoinjury to persons.
DANGER!
Thecatchword“DANGER”usedinconjunctionwiththegeneralcautionsymboldesignatessafety
anddangernotesin this documentation that, ifneglected,mayleadtosevere injury or even
death of persons.
Safekeeping
Pleasesafeguardthesemountinginstructionsinasafeplace,whereitcanbeimmediatelyaccessed.
Iftheequipmentchangeshands,thedocumentationshouldbepassedontothenewoperator.
Ifthedocumentationgetsmislaid,pleasecontactyourNordmannsupplier.
Language versions
Thesemountinginstructionsisavailableinvariouslanguages.PleasecontactyourNordmannsup-
plierforinformation.
Copyright protection
ThepresentmountinginstructionsareprotectedundertheCopyrightAct.Passing-onandreproduc-
tionofthemanual(orpartthereof)aswellasexploitationandcommunicationofthecontentsare
prohibitedwithoutwrittenpermissionbythemanufacturer.Violationofcopyrighttermsissubjectto
legalprosecutionandarisesliabilityforindemnication.
Themanufacturerreservestherighttofullyexploitcommercialpatentrights.

6
2 For your safety
General
EverypersonworkingwiththeNordmannRC4/DC4musthavereadandunderstoodthemounting
instructionsbeforecarryingoutanyinstallationwork.
Knowingandunderstandingthecontentsofthemountinginstructionsis a basic requirement for
protectingthepersonnelagainstanykindofdanger,topreventfaultyinstallation,andtoinstalland
operatetheunitsafelyandcorrectly.
All ideograms, signs and markings applied to the unit must be observed and kept in readable
state.
Qualicationofpersonnel
Allactionsdescribedinthepresentmountinginstructionsmustbecarriedoutonlybywell trained
andsufcientlyqualiedpersonnelauthorisedbytheowner.
Forsafetyandwarrantyreasonsanyactionbeyondthescopeofthismanualsmustbecarriedout
onlybyqualiedpersonnelauthorisedbythemanufacturer.
ItisassumedthatallpersonsworkingwiththeNordmannRC4/DC4arefamiliarandcomplywiththe
appropriateregulationsonworksafetyandthepreventionofaccidents.
Intended use
ThesteamhumidierNordmannRC4/DC4isintendedexclusivelyforairhumidicationviaasteam
distributor approved by the manufacturer(unitversionsNordmann DC4)or via the integrated
ventilation unit(unitversionsNordmann RC4)withinthespeciedoperatingconditions(see
chapter6“Productspecications”).Anyothertypeofapplicationwithouttheexpresswrittenconsent
ofthemanufacturerisconsideredasnotconformingwiththeintendedpurposeandmayleadtothe
NordmannRC4/DC4becomingdangerous.
Operationoftheequipmentintheintendedmannerrequiresthat all the information in these in-
structions is observed (in particular the safety instructions).
Danger that may arise from the unit:
The Nordmann RC4/DC4 is mains powered.
DANGER!
One may get in touch with live parts when the unit is open. Touching live parts may cause
severe injury or danger to life.
Prevention:Thesteamhumidiermustbeconnectedtothemainsonlyafterallmountingand
installationworkhasbeencompletedandthecoverhasbeenrelocatedproperly.

7
Behaviour in case of danger
AllpersonsworkingwiththeNordmannRC4/DC4areobligedtoreportanyalterationstotheunit
thatmayaffectsafetytotheownerwithoutdelayandtosecuresuchaunitagainstaccidentalpower-
up.
Prohibitedmodicationstotheunit
NomodicationsmustbeundertakenontheNordmannRC4/DC4withouttheexpresswritten
consentofthemanufacturer.
Forthereplacementofdefectivecomponentsuseexclusivelyoriginal accessories and spare parts
availablefromyourNordmannsupplier.

8
3 Product Overview
3.1 Models overview
Steam air humidiers Nordmann RC4/DC4 are available in the two basic versions for duct air
humidicationanddirectroomairhumidication with different heating voltagesandsteam
capacities of 2 kg/h and 4 kg/h.
Model Nordmann
Duct Room
DC4 RC4
Max.steamcapacity 2kg/h 4kg/h 2kg/h 4kg/h
Heatingvoltages 230V1~/50..60Hz
240V1~/50..60Hz
200V2~/50..60Hz
Integratedventilationunit ––– X
Displayandcontrolunit X
ExternalOn/Offcontrol X
ExternalP/PIcontrol X
InternalP/PIcontroller X
Admissiblecontrolsignals 0–5V,1–5V,0–10V,2–10V,
0–16V,3.2–16V,0–20mA,4–20mA
Operatingparameter congurableviacontrolsoftware
3.2 Identicationoftheunit
Theidenticationoftheunitisfoundonthetypeplate(forthelocationofthetypeplateseeunit
overview):
Typedesignation Serialnumber Month/Year
Heatingvoltage
Maximumsteamcapacityperunit
Admissiblewatersupplypressure
Powerconsumption
Controlvoltage
Fieldwithcerticationsymbols
Walter Meier (Climate International) Ltd. 8808 Pfäfkon
Type: Nordmann DC4 Ser.Nr.: XXXXXXX 06.09
Heating Voltage: 230V / 1~ / 50...60Hz Power: 3.1 kW / 13.5 A
Steam Capacity: 4.0 kg/h Ctrl.Voltage: 230V / 1~ / 50...60Hz
Water Pressure: 1...10 bar
Made in Switzerland

9
3.3 Steamhumidierconstruction
1 Backpanel
2 Watercup
3 Watersupplyhose
4 Heatingelectrodes
5 Filling hose
6 Overowhose
7 Steamcylinder
8 Inletvalve(notvisible)
9 Drainpump
10 Waterdrainconnector(notvisible)
11 Watersupplyconnector(notvisible)
12 Tub
13 Powerboard
14 Typeplate
15 Remoteoperatingandfaultindicationboard
(Option)
16 ControlboardwithCFcard
17 Unit switch
18 Drainkey
19 Displayandcontrolunit
20 Operationstatusindicators(LED's)
21 Intermediatepanel
22 Front cover
23 Levelsensor
24 Steamoutletconnector
Construction Nordmann DC4
1
2
4
5
7
6
9
3
17 13 1214 101516
23
22
21
24
11
19
18
20
8

10
Construction Nordmann RC4
1 Backpanel
2 Watercup
3 Watersupplyhose
4 Heatingelectrodes
5 Filling hose
6 Overowhose
7 Steamcylinder
8 Inletvalve(notvisible)
9 Drainpump
10 Waterdrainconnector(notvisible)
11 Watersupplyconnector(notvisible)
12 Tub
13 Powerboard
14 Typeplate
15 Remoteoperatingandfaultindicationboard
(Option)
16 ControlboardwithCFcard
17 Unit switch
18 Drainkey
19 Displayandcontrolunit
20 Operationstatusindicators(LED's)
21 Unitintermediatepanel
22 Front cover
23 Levelsensor
24 Condensatehose
25 Ventilationunit
1
2
4
5
7
6
9
3
17 13 1214 101516
23
22
21
24
25
11
19
18
20
8
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Andere Nordmann Luftbefeuchter Handbücher

Nordmann
Nordmann AT4 Series Bedienungsanleitung

Nordmann
Nordmann DC4 Bedienungsanleitung

Nordmann
Nordmann 2401935EN0801 Bedienungsanleitung

Nordmann
Nordmann NOVAP 3000 Bedienungsanleitung

Nordmann
Nordmann AT4 Series Bedienungsanleitung

Nordmann
Nordmann AT 3000 series Bedienungsanleitung

Nordmann
Nordmann ES4 Betriebsanleitung

Nordmann
Nordmann es4 4 Bedienungsanleitung