Nordson Encore Referenzhandbuch

EncorerEngage Gateway
Customer Product Manual
Part 1615959−01
Issued 03/19
NORDSON CORPORATION •AMHERST, OHIO •USA
For parts and technical support, call the
Finishing Customer Support Center at (800) 433-9319.
This document is subject to change without notice.
Check http://emanuals.nordson.com for the latest version.

Part 1615959−01 E2019 Nordson Corporation
tents
Table of Contents
Safety 1.......................................
Qualified Personnel 1.........................
Intended Use 1..............................
Regulations and Approvals 1..................
Personal Safety 2............................
Fire Safety 2................................
Grounding 3.................................
Action in the Event of a Malfunction 3...........
Disposal 3..................................
Description 4..................................
Installation 5..................................
Installing Gateway into
External/Auxiliary Controller 5.................
Electrical Power 6............................
Fieldbus Connection 6.......................
Gateway PCA (Printed Circuit Assembly)
Board Jumper Settings 7.....................
Software 8....................................
Overview 8..................................
Hardware Requirements 9....................
PCA −PLC Gateway Controller 9............
Anybus Network Interface Module 9.........
Gateway Software 10..........................
Software Version 11........................
Addressing Modes 12.........................
Broadcast Messages 12.....................
Multicast Messages 12......................
Unicast Messages 12.......................
IO Image Table Configuration 13................
IO Image Table −Module Definitions 15.......
Sending Messages from the PLC 24.............
Broadcast Messages from the PLC
(IO Module 1) 26...........................
Multicast Messages from the PLC
(IO Modules 2 and 8) 28....................
Unicast Messages from the PLC 28...........
Flow % Adjust Message 31..................
Reading Data at the PLC −Input Image Table 32..
Gun Monitored Data 32.....................
General System Status 38..................
Gateway Heartbeat 39......................
Parts 40.......................................
Gateway Replacement Parts 40.................
Optional Equipment 40........................
Contact Us
Nordson Corporation welcomes requests for information, comments, and
inquiries about its products. General information about Nordson can be
found on the Internet using the following address:
http://www.nordson.com.
Address all correspondence to:
Nordson Corporation
Attn: Customer Service
555 Jackson Street
Amherst, OH 44001
Notice
This is a Nordson Corporation publication which is protected by copyright.
Original copyright date 2019. No part of this document may be
photocopied, reproduced, or translated to another language without the
prior written consent of Nordson Corporation. The information contained
in this publication is subject to change without notice.
Trademarks
Encore, HDLV, Nordson, and the Nordson logo are registered trademarks
of Nordson Corporation.
All other trademarks are the properties of their respective owners.

Change Record i
Part 1615959−01
E2019 Nordson Corporation
Change Record
Revision Date Change
01 03/19 New Release.

Change Record
ii
Part 1615959−01 E2019 Nordson Corporation

EncorerEngage Gateway 1
Part 1615959−01
E2019 Nordson Corporation
EncorerEngage Gateway
Safety
Read and follow these safety instructions. Task- and equipment-specific
warnings, cautions, and instructions are included in equipment
documentation where appropriate.
Make sure all equipment documentation, including these instructions, is
accessible to all persons operating or servicing equipment.
Qualified Personnel
Equipment owners are responsible for making sure that Nordson equipment
is installed, operated, and serviced by qualified personnel. Qualified
personnel are those employees or contractors who are trained to safely
perform their assigned tasks. They are familiar with all relevant safety rules
and regulations and are physically capable of performing their assigned
tasks.
Intended Use
Use of Nordson equipment in ways other than those described in the
documentation supplied with the equipment may result in injury to persons
or damage to property.
Some examples of unintended use of equipment include
Susing incompatible materials
Smaking unauthorized modifications
Sremoving or bypassing safety guards or interlocks
Susing incompatible or damaged parts
Susing unapproved auxiliary equipment
Soperating equipment in excess of maximum ratings
Regulations and Approvals
Make sure all equipment is rated and approved for the environment in which
it is used. Any approvals obtained for Nordson equipment will be voided if
instructions for installation, operation, and service are not followed.
All phases of equipment installation must comply with all federal, state, and
local codes.

EncorerEngage Gateway
2
Part 1615959−01 E2019 Nordson Corporation
Personal Safety
To prevent injury follow these instructions.
SDo not operate or service equipment unless you are qualified.
SDo not operate equipment unless safety guards, doors, or covers are
intact and automatic interlocks are operating properly. Do not bypass or
disarm any safety devices.
SKeep clear of moving equipment. Before adjusting or servicing any
moving equipment, shut off the power supply and wait until the
equipment comes to a complete stop. Lock out power and secure the
equipment to prevent unexpected movement.
SRelieve (bleed off) hydraulic and pneumatic pressure before adjusting or
servicing pressurized systems or components. Disconnect, lock out,
and tag switches before servicing electrical equipment.
SObtain and read Material Safety Data Sheets (MSDS) for all materials
used. Follow the manufacturer’s instructions for safe handling and use
of materials, and use recommended personal protection devices.
STo prevent injury, be aware of less-obvious dangers in the workplace
that often cannot be completely eliminated, such as hot surfaces, sharp
edges, energized electrical circuits, and moving parts that cannot be
enclosed or otherwise guarded for practical reasons.
Fire Safety
To avoid a fire or explosion, follow these instructions.
SDo not smoke, weld, grind, or use open flames where flammable
materials are being used or stored.
SProvide adequate ventilation to prevent dangerous concentrations of
volatile materials or vapors. Refer to local codes or your material MSDS
for guidance.
SDo not disconnect live electrical circuits while working with flammable
materials. Shut off power at a disconnect switch first to prevent
sparking.
SKnow where emergency stop buttons, shutoff valves, and fire
extinguishers are located. If a fire starts in a spray booth, immediately
shut off the spray system and exhaust fans.
SClean, maintain, test, and repair equipment according to the instructions
in your equipment documentation.
SUse only replacement parts that are designed for use with original
equipment. Contact your Nordson representative for parts information
and advice.

EncorerEngage Gateway 3
Part 1615959−01
E2019 Nordson Corporation
Grounding
WARNING: Operating faulty electrostatic equipment is hazardous and can
cause electrocution, fire, or explosion. Make resistance checks part of your
periodic maintenance program. If you receive even a slight electrical shock
or notice static sparking or arcing, shut down all electrical or electrostatic
equipment immediately. Do not restart the equipment until the problem has
been identified and corrected.
Grounding inside and around the booth openings must comply with NFPA
requirements for Class II Division 1 or 2 Hazardous Locations. Refer to
NFPA 33, NFPA 70 (NEC articles 500, 502, and 516), and NFPA 77, latest
conditions.
SAll electrically conductive objects in the spray areas shall be electrically
connected to ground with a resistance of not more than 1 megohm as
measured with an instrument that applies at least 500 volts to the circuit
being evaluated.
SEquipment to be grounded includes, but is not limited to, the floor of the
spray area, operator platforms, hoppers, photoeye supports, and
blow-off nozzles. Personnel working in the spray area must be
grounded.
SThere is a possible ignition potential from the charged human body.
Personnel standing on a painted surface, such as an operator platform,
or wearing non-conductive shoes, are not grounded. Personnel must
wear shoes with conductive soles or use a ground strap to maintain a
connection to ground when working with or around electrostatic
equipment.
SOperators must maintain skin-to-handle contact between their hand and
the gun handle to prevent shocks while operating manual electrostatic
spray guns. If gloves must be worn, cut away the palm or fingers, wear
electrically conductive gloves, or wear a grounding strap connected to
the gun handle or other true earth ground.
SShut off electrostatic power supplies and ground gun electrodes before
making adjustments or cleaning powder spray guns.
SConnect all disconnected equipment, ground cables, and wires after
servicing equipment.
Action in the Event of a Malfunction
If a system or any equipment in a system malfunctions, shut off the system
immediately and perform the following steps:
SDisconnect and lock out electrical power. Close pneumatic shutoff
valves and relieve pressures.
SIdentify the reason for the malfunction and correct it before restarting the
equipment.
Disposal
Dispose of equipment and materials used in operation and servicing
according to local codes.

EncorerEngage Gateway
4
Part 1615959−01 E2019 Nordson Corporation
Description
The Gateway is the interface between a main system controller (usually a
PLC) and any of the Engage controllers’ dual channel control modules used
with automatic powder guns.
The Gateway converts standard fieldbus protocol messages and commands
(PROFINETror EtherNet/IPt) from a main system controller into the
proprietary CAN bus messages required to communicate with the pump and
electrostatic modules controlling the automatic spray guns.
See Figure 1. The Gateway is capable of interfacing with up to 32
automatic guns through a single cable to the spray control modules. For a
system with the maximum of 32 spray guns, there are 16 KV nodes and 16
flow nodes connected on a CAN network.
The system is compatible with Encorerand Encore HD automatic guns.
Main System Controller:
PLC, PC, or Robot Controller
Spray Gun
Fieldbus
Wiring
External/Auxiliary Controller
(has no PC touchscreen) Gun Cable
Gateway is in
Slot 9 of card cage
Figure 1 Typical System Diagram

EncorerEngage Gateway 5
Part 1615959−01
E2019 Nordson Corporation
Installation
WARNING: Allow only qualified personnel to perform the following tasks.
Follow the safety instructions in this document and all other related
documentation.
WARNING: Use dust-tight conduit connectors or strain reliefs to route
cables into all electrical enclosures. Installation must be done according to
code and care must be taken to maintain the dust-tight integrity of the
enclosures.
Installing Gateway into External/Auxiliary Controller
See Figure 2. The Gateway may be inserted into Slot 9 of the card cage.
Additional application installation options include:
SA card cage mounted in a custom-built electrical enclosure.
SA Gateway mounted into a single-slot package, mounted in a custom
electrical enclosure (see page 40).
Card Cage
Sub Panel
Slots 1 −8 reserved for
Dual Gun Driver PCAs
Slot 9 for Gateway
External/Auxiliary Controller
Figure 2 Installing Gateway into External/Auxiliary Controller

EncorerEngage Gateway
6
Part 1615959−01 E2019 Nordson Corporation
Electrical Power
The Gateway requires 24 Vdc @ 100mA (maximum), which is supplied by
the card cage backplane.
Fieldbus Connection
The fieldbus connection is made directly to the Anybusrsupport board,
which is mounted to the Gateway board. The customer must provide the
appropriate cable for PROFINET or EtherNet/IP networks.
Andere Handbücher für Encore
8
Inhaltsverzeichnis
Andere Nordson Tor Handbücher
Beliebte Tor Handbücher anderer Marken

LST
LST M500RFE-AS Bedienungsanleitung

Kinnex
Kinnex Media Gateway Bedienungsanleitung

2N Telekomunikace
2N Telekomunikace 2N StarGate Bedienungsanleitung

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries Superlink SC-WBGW256 Bedienungsanleitung

ZyXEL Communications
ZyXEL Communications ZYWALL2 ET 2WE Bedienungsanleitung

Telsey
Telsey CPVA 500 - SIP Bedienungsanleitung











