OBID ID CPRPOS Bedienungsanleitung

INSTALLATION
final – public (B)
2015-07-27 – ID CPRPOS User Manual-01.doc
ID CPRPOS
Card reader for contactless and contact smart cards

OBID
®
classic-pro
Installation
ID CPRPOS
FEIG ELECTRONIC GmbH Page 2 of 18 ID CPRPOS User Manual-01.doc
Note
Copyright 2015 by
FEIG ELECTRONIC GmbH
Lange Strasse 4
D-35781 Weilburg
Tel.: +49 6471 3109-0
http://www.feig.de
With the edition of this document, all previous editions become void. Indications made in this manual may be
changed without previous notice.
The reproduction, distribution and utilization of this document as well as the communication of its contents to others
without express authorization is prohibited. Offenders will be held liable for the payment of damages. All rights reserved
in the event of the grant of a patent, utility model or design.
Composition of the information in this document has been done to the best of our knowledge. FEIG
ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this
manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since,
despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips.
The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC
GmbH does not give any guarantee promise for perfect function in cross environments and does not give
any guaranty for the functionality of the complete system which incorporates the subject of this document.
FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed
with components and testing methods for a level of reliability suitable for use in or in connection with surgical
implants or as critical components in any life support systems whose failure to perform can reasonably be
expected to cause significant injury to a human. To avoid damage, injury, or death, the user or application
designer must take reasonably prudent steps to protect against system failures.
FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this
document and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH
does not convey any license under its patent rights nor the rights of others.
OBID®and OBID myAXXESS®is a registered trademark of FEIG ELECTRONIC GmbH.
All brand names, trademarks or logos are property of their respective owners.

OBID
®
classic-pro
Installation
ID CPRPOS
FEIG ELECTRONIC GmbH Page 3 of 18 ID CPRPOS User Manual-01.doc
Contents
1. Safety Instructions / Warning - Read before start-up ! 4
2. Characteristics of the ID CPRPOS 5
2.1. Scope of delivery...............................................................................................................5
2.2. Available accessories and spare parts............................................................................6
3. Dimensions 7
4. Connections 8
4.1. Ethernet interface..............................................................................................................9
4.2. USB interface...................................................................................................................10
4.3. RS232 interface / Power supply......................................................................................11
5. Display and LED 12
5.1. Display .............................................................................................................................12
5.2. LED...................................................................................................................................13
6. Installation of a Secure Access Module (SAM) 14
7. Radio Approvals 15
7.1. Europe (CE)......................................................................................................................15
7.2. USA (FCC) and Canada (IC)............................................................................................15
8. Technical Data 17

OBID
®
classic-pro
Installation
ID CPRPOS
FEIG ELECTRONIC GmbH Page 4 of 18 ID CPRPOS User Manual-01.doc
1. Safety Instructions / Warning - Read before start-up !
•The device may only be used for the intended purpose designed by for the manufacturer.
•The operation manual should be conveniently kept available at all times for each user.
•Unauthorized changes and the use of spare parts and additional devices which have not been
sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such
unauthorized measures shall exclude any liability by the manufacturer.
•The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid
for the device. The manufacturer shall not be held legally responsible for inaccuracies, errors,
or omissions in the manual or automatically set parameters for a device or for an incorrect
application of a device.
•Repairs may only be executed by the manufacturer.
•Installation, operation, and maintenance procedures should only be carried out by qualified
personnel.
•Use of the device and its installation must be in accordance with national legal requirements
and local electrical codes .
•When working on devices the valid safety regulations must be observed.
•Special advice for carriers of cardiac pacemakers:
Although this device doesn't exceed the valid limits for electromagnetic fields you should keep
a minimum distance of 25 cm between the device and your cardiac pacemaker and not stay in
an immediate proximity of the device respective the antenna for some time.

OBID
®
classic-pro
Installation
ID CPRPOS
FEIG ELECTRONIC GmbH Page 5 of 18 ID CPRPOS User Manual-01.doc
2. Characteristics of the ID CPRPOS
The ID CPRPOS is a smart card reader for contactless and contact smart cards according to ISO
14443-A/B and ISO 7816. The reader is designed as desktop device and is due to the support of
different chip types like mifare classic, mifare DESFire and mifare PLUS suitable for a wide range
of applications. In addition to the contact based smart card interface for ID-1 sized smart cards the
ID CPRPOS has one SAM socket for ID-000 sized smart cards available.
The ID CPRPOS can be connected and controlled by a host system via its RS232, USB or Ether-
net interface. A connected host system is able to use the ID CPRPOS to communicate with smart
cards and to control the user guidance via display, LED and buzzer. The reader could be config-
ured by the connected host system, too.
Figure 1: Surface of the ID CPRPOS
2.1. Scope of delivery
The scope of delivery includes following components:
•1 x Electronic unit ID CPRPOS
•1 x Power supply unit
•1 x USB connection cable
•1 x Wire strap
display
contact
smart card interface
contactless
smart card interface

OBID
®
classic-pro
Installation
ID CPRPOS
FEIG ELECTRONIC GmbH Page 6 of 18 ID CPRPOS User Manual-01.doc
2.2. Available accessories and spare parts
Table 1: Available accessories and spare parts
Order Number Article Description
4219.000.00 OBID myAXXESS
ID NET.5V-EU
Power supply unit (5 V DC / 1 A); Length of the connection
cable: 1,5 m
4218.000.00 ID CAB.RS-C
RS232 connection cable incl. connector for power supply
- Host connector: D-SUB 9 poles
- Device connector: RJ-12 plug 6 poles
- Power supply connector: RJ-12 jack 6 poles
- Length: 2,0 m

OBID
®
classic-pro
Installation
ID CPRPOS
FEIG ELECTRONIC GmbH Page 7 of 18 ID CPRPOS User Manual-01.doc
3. Dimensions
The ID CPRPOS is designed as desktop device. Its small form factor offers the possibility to place
the reader directly on a sales counter or at a cashier station. Due to its rubber feet the reader is
suitable for slippery undergrounds.
Figure 2: Top view
Figure 3: Side view

OBID
®
classic-pro
Installation
ID CPRPOS
FEIG ELECTRONIC GmbH Page 8 of 18 ID CPRPOS User Manual-01.doc
4. Connections
Figure 4: ID CPRPOS - position of the connectors
Ethernet interface (RJ-45)
USB interface (Mini-USB)
RS232 interface and power supply (RJ-12)
NOTE:
Only one host interface should be used at the same time. The usage of more than one host
interface at the same time can cause malfunctions.

OBID
®
classic-pro
Installation
ID CPRPOS
FEIG ELECTRONIC GmbH Page 9 of 18 ID CPRPOS User Manual-01.doc
4.1. Ethernet interface
The ID CPRPOS has an integrated 10/100 base-T network port with a common RJ-45 connector
and an automatic “crossover correction”.
With structured cabling CAT5 cables should be used. This ensures a reliable operation at 10 Mbps
and 100 Mbps.
The prerequisite for using TCP/IP protocol is that each device has a unique address on the net-
work. All readers have a factory set IP address. The communication parameter could be configured
user-defined.
Table 2: Standard factory configuration of the ethernet interface
Network Address
IP address 192.168.10.10
Subnet mask 255.255.0.0
Port 10001
DHCP OFF
NOTE:
•The reader is equipped with a DHCP ready ethernet interface.
•It is recommended to use a screened STP (shielded twisted pair) CAT5 cable.

OBID
®
classic-pro
Installation
ID CPRPOS
FEIG ELECTRONIC GmbH Page 10 of 18 ID CPRPOS User Manual-01.doc
4.2. USB interface
The ID CPRPOS is equipped with a USB on-the-go interface (USB mini jack). It allows a direct
connection to a host system for controlling, configuration and firmware update of the device (ID
CPRPOS is USB slave). In addition the ID CPRPOS offers the possibility to connect an external
USB memory stick to the electronic unit by means of a USB on-the-go adaptor (ID CPRPOS is
USB master).
Figure 5: USB mini jack
Figure 6: USB mini cable for host connection
With the delivered wire strap the USB cable could be fixed at the housing and a strain relief for the
cable connection could be established.
NOTE:
The device needs a separate power supply via the RJ-12 jack. A power supply of the device
via the USB interface is not supported.
Inhaltsverzeichnis
Andere OBID Kartenleser Handbücher
Beliebte Kartenleser Handbücher anderer Marken

Rosslare
Rosslare DR-6255 Bedienungsanleitung

Lindy
Lindy 51541 Bedienungsanleitung

Diapro T?bbi Ürünler
Diapro T?bbi Ürünler Across System Bedienungsanleitung

Johnson Controls
Johnson Controls Kantech tyco ioSmart Bedienungsanleitung

ACS
ACS ACR122L Bedienungsanleitung

Secukey
Secukey S2-MF Bedienungsanleitung