Omega Engineering OS136 SERIES Bedienungsanleitung

OS136 SERIES
Miniature Low-Cost
Non-Contact Infrared
Temperature Sensor/Transmitter
CAUTION!
– This product
is not intended for medical
use or use on humans
e-mail: [email protected]
For latest product manuals:
omegamanual.info
Shop online at
omega.com
®
User’s Guide
®

Servicing North America:
U.S.A.: Omega Engineering, Inc., One Omega Drive, P.O. Box 4047
ISO 9001 Certified Stamford, CT 06907-0047 USA
Toll Free: 1-800-826-6342 TEL: (203) 359-1660
Canada: 976 Bergar
Laval (Quebec), H7L 5A1 Canada
Toll-Free: 1-800-826-6342 TEL: (514) 856-6928
For immediate technical or application assistance:
U.S.A. and Canada: Sales Service: 1-800-826-6342/1-800-TC-OMEGA®
Customer Service: 1-800-622-2378/1-800-622-BEST®
Engineering Service: 1-800-872-9436/1-800-USA-WHEN®
Mexico/ En Español: 001 (203) 359-7803 FAX: 001 (203) 359-7807
Servicing Europe:
Benelux: Managed by the United Kingdom Office
Toll-Free: 0800 099 3344 TEL: +31 20 347 21 21
Czech Republic: Frystatska 184
733 01 Karviná, Czech Republic
Toll-Free: 0800-1-66342 TEL: +420-59-6311899
France: Managed by the United Kingdom Office
Toll-Free: 0800 466 342 TEL: +33 (0) 161 37 29 00
Germany/Austria: Daimlerstrasse 26
D-75392 Deckenpfronn, Germany
Toll-Free: 0800 6397678 TEL: +49 (0) 7056 9398-0
United Kingdom: OMEGA Engineering Ltd.
ISO 9001 Certified One Omega Drive, River Bend Technology Centre, Northbank
Irlam, Manchester M44 5BD United Kingdom
Toll-Free: 0800-488-488 TEL: +44 (0) 161 777-6611
OMEGAnet®Online Service Internet e-mail
omega.com [email protected]
It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI
regulations that apply. OMEGA is constantly pursuing certification of its products to the European New
Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct, but OMEGA accepts no liability for any
errors it contains, and reserves the right to alter specifications without notice.
WARNING: These products are not designed for use in, and should not be used for, human applications.
®

i
OS136 Series Miniature Low-Cost Non-Contact Infrared
Temperature Sensor/Transmitter
Table of Contents
Section Page
Caution and Safety Information .................................................................. iii
Safety Warnings and IEC Symbols .............................................................. iii
Section 1 Introduction .................................................................................... 1
Section 2 Installation ...................................................................................... 1
2.1 Unpacking .................................................................................. 1
2.2 Electrical Connection ................................................................ 2
Section 3 Operation ......................................................................................... 3
3.1 Measuring Temperature ........................................................... 3
3.2 Ambient Temperature ............................................................... 3
3.3 Atmospheric Quality ................................................................ 4
Section 4 Laser Sight Accessory .................................................................... 6
4.1 Warnings and Caution .............................................................. 6
4.2 Operating the Laser Sight Accessory ..................................... 6
Section 5 Specifications .................................................................................. 8
5.1 General ........................................................................................ 8
5.2 Laser Sight Accessory ............................................................... 9

OS136 Series Miniature Low-Cost Non-Contact Infrared Temperature Sensor/Transmitter
ii
List of Figures
Figure Description Page
2-1 General Wiring Diagram ................................................................ 2
3-1 Optical Field of View ...................................................................... 3
3-2 Mounting Bracket, OS100-MB ....................................................... 4
3-3 Air Purge Collar, OS100-AP ........................................................... 4
3-4 Stainless Steel Housing .................................................................. 5
3-5 Water/Air Cool Jacket, OS136-WC .............................................. 5
3-6 Water/Air Cool Jacket Assembly ................................................. 5
4-1 Laser Sighting Accessory, OS100-LS ............................................. 7
4-2 Laser Warning Label........................................................................ 7

OS136 Series Miniature Low-Cost Non-Contact Infrared Temperature Sensor/Transmitter
iii
CAUTION & SAFETY INFORMATION
If the equipment is used in a manner not specified in this manual, the protection
provided by the equipment may be impaired.
The Installation category is one (1).
There is no user replaceable fuse in this product.
The output terminals of this product are for use with equipment (Digital meters,
chart recorders, etc.) which have no accessible live parts. Such equipment should
comply with all the applicable safety requirements.
Do not operate the equipment in flammable or explosive environments.
The unit comes with a 1.82 m (6') shielded cable for power and output
connections. The cable is a multi-conductor, 24 AWG stranded wire with the
rating of 600 VDC, 205ºC, (401°F) Teflon®insulation.
Power must be disconnected before making any electrical connections.
The recommended power supply should be VDE or UL approved. Rating:12-24
VDC @ 50 mA min. power with overload protection.
The supply voltage to the transmitter should not exceed 24 VDC.
SAFETY WARNINGS AND IEC SYMBOLS
This device is marked with international safety and hazardous symbols in
accordance with IEC1010. It is important to read and follow all the precautions
and instructions in this manual before operating or commissioning this device as
it contains important information relating to safety and EMC. Failure to follow
all the safety precautions may result in injury and/or damage to your
equipment.
IEC Symbol Description
Caution - Refer to the accompanying
document(s).
Direct Current
Laser Symbol

1
SECTION 1 - INTRODUCTION
The model OS136 series is a very low-cost, super-compact infrared transmitter. It
measures temperature via non-contact, and provides an analog output
proportional to the measured temperature. The OS136 series is offered in two
temperature ranges: -18 to 204ºC (0 to 400ºF) and 149 to 538ºC (300 to 1000ºF).
The analog output is offered as 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc, 10
mV/Degree C or F, or K type thermocouple.
The unit has a fixed Emissivity of 0.95 which makes it easy to measure
temperature, requiring no adjustments during installation and use.
The super-compact design, 19 mm OD x 89 mm Length (0.75" OD x 3.5" L) is
ideal to measure temperature in confined, and hard to reach places. The Stainless
Steel housing is NEMA-4 rated. The unit comes with a 1.82 m (6') shielded cable
as standard.
SECTION 2 – INSTALLATION
2.1 – Unpacking
Remove the packing list and verify that you have received all your equipment. If
you have any questions about the shipment, please call the Customer Service at:
1-800-622-2378 or 203-359-2208. We can also be reached on the internet at
omega.com
email: [email protected]
When you receive the shipment, inspect the container and the equipment for any
signs of damage. Note any evidence of rough handling in transit. Immediately
report any damage to the shipping agent.
The carrier will not honor any damage claims unless all the
shipping materials are saved for inspection. After
examination and removing contents, save packing material
and carton in the event reshipment is necessary.
The following items are supplied in the box:
• The infrared transmitter, OS136 with the 1.82 m (6') shielded cable.
• Two Mounting Nuts
• User’s Guide
Introduction
1
NOTE:

2
2
The following describes the ordering information:
OS136 – * – ** , where
- * means:
-1 : -18 to 204ºC (0 to 400ºF) Temperature range
-2 : 149 to 538ºC (300 to 1000ºF) Temperature range
- ** means:
-MA : 4 to 20 mA current output
-V1 : 0 to 5 Vdc output
-V2 : 0 to 10 Vdc output
-K : K type thermocouple output
-MVC : 10 mV/ºC output
-MVF : 10 mV/ºF output
The following table lists the optional accessories:
2.2 – Electrical Connection
The shielded cable provides the power and output connections. Fig 2-1 shows
the wiring diagram for different analog outputs.
Figure 2-1. General Wiring Diagram
Accessories
Model No. Description
OS100-MB Mounting Bracket
OS136-WC Water/Air Cooling Jacket
OS100-AP Air Purge Collar
OS100-LS Laser Sighting
PSU-93 Unregulated 16-24 VDC Power Supply
CAL-3-IR NIST Traceable Calibration
Installation
RED
WHITEYELLOW
THERMOCOUPLE
METER/
RECORDER
12-24 Vdc
POWER SUPPLY
GREENRED
-OR-
10 mV/Deg
0/5 Vdc or 4-20 mA
or 0/10 Vdc
EARTH
GROUND
DIGITAL
VOLTMETER/
AMMETER/
RECORDER
K TYPE
THERMOCOUPLES
BLACK
SHIELD
+
+
+
–
–
–
OS136
WHITE
12-24 Vdc
POWER SUPPLY
EARTH
GROUND
BLACK
SHIELD
+
–

3
Operation
3
SECTION 3 – OPERATION
3.1 – Measuring Temperature
Before starting to measure temperature, make sure the following check list is met:
The Power and output connections are made (Fig 2-1)
The target is larger than the optical field of view of the transmitter (Fig 3-1)
Use the Laser Sighting accessory (Optional), to align the transmitter to the
center of the target area.
The Emissivity is fixed at 0.95. No adjustment is necessary. If the target
Emissivity is less than 0.95, you can place a masking tape or paint the target
area with flat black paint to raise the surface Emissivity to 0.95.
Make sure the output load is within the product specification.
Figure 3-1. Optical Field of View
3.2 – Ambient Temperature
The transmitter can operate in an ambient temperature of 0 to 70°C (32 to 158°F)
without any water cool jacket. It can operate from 0 to 200°C (32 to 392°F) with
the water cool jacket accessory, OS136-WC (Fig 3-5 & 3-6). It can operate up to
110°C (230°F) with air cooling.
There is a warm up period of 1 to 2 minutes after power up. After the warm up
period, temperature measurement can be made.
When the ambient temperature around the transmitter changes abruptly, the sensor
head goes through a thermal shock. It takes a certain amount of time for the sensor
head to get stabilized to the new ambient temperature. For example, it takes about
30 minutes for the transmitter to stabilize from 25°C to 50°C ambient temperature.
SPOT DIA.* (CM) SPOT DIA.* (IN)
DISTANCE: SENSOR TO OBJECT (IN)
D:S=6:1
1cm@0
020
3.3
40
6.6
60
10.0
80
13.0
100
16.0
122
20.0
0.4"@0"
2.0"
1.0"
4.0"
6.0" 8.0"
48"
36"
24"
12"6"
0"
DISTANCE: SENSOR TO OBJECT (CM)
* SPOT DIAMETER MEASURED AT 90% ENERGY

Operation 3
4
3.3 - Atmospheric Quality
Environments with smoke , dust, and fume dirty up the optical lens, and cause
erroneous temperature readings. To keep the surface of the optical lens clean, the
air purge collar accessory is recommended, OS136-AP (Fig 3-3).
The following figures show the Mounting Bracket (OS136-MB), Air Purge Collar
(OS136-AP), Stainless Steel Housing, Water/Air Cool Jacket (OS136-WC), and
the Water/Air Cool Jacket Assembly.
Figure 3-2. Mounting Bracket, OS100-MB
Figure 3-3. Air Purge Collar, OS100-AP
23.3
(0.919)
Ø 19
(0.755)
Ø 4
(0.156)
31.8
(1.25)
90°
3.2
(1/8)
12.7
(0.5)
12.7
(0.5)
50.0
(1.97)
3.2
(1/8)
25.4
(1)
42.9
(1.69)
Dimensions mm (in.)
Dimensionsmm (in.)
28.6
(1.125)
1/16 NPT
COMPRESSION
FITTING
3/4-16 UNF 2B
THRU.
17.5
(0.69)

Figure 3-4. Stainless Steel Housing
Figure 3-5. Water/Air Cool Jacket, OS136-WC
Figure 3-6. Water/Air Cool Jacket Assembly
Operation
3
5
LIGHT HEX KNURL
4.76 (3/16) WIDE
DIMENSIONSmm (in)
3/4-16 UNF
88.9
(3.5)
1.83m
(6ft)
33.27
(1.31)
19.05
(0.75)
1/8NPT COMPRESSION
FITTING, 2 PLCS.
34.80
(1.37)
85.09
(3.35)
7.62
(0.30)
3/4-16 UNF-2B
3/4-16 UNF
INLET OUTLET
Dimensions mm (in.)
MOUNTING
BRACKET
OUTLETINTLET
OS137
UP TO 200°C (392°F) AMBIENT TEMPERATURE WITH WATER COOLING
MOUNTING
NUT
Dimensions mm (in.)
Inhaltsverzeichnis
Andere Omega Engineering Temperaturregler Handbücher
Beliebte Temperaturregler Handbücher anderer Marken

Swegon
Swegon LUNAd MB Bedienungsanleitung

Lucky Reptile
Lucky Reptile Thermo Control II Bedienungsanleitung

SENSORMETRIX
SENSORMETRIX Argon 100 Bedienungsanleitung

Fuji Electric
Fuji Electric PXE4 Bedienungsanleitung

Yuyao gongyi
Yuyao gongyi XMT-808 series Bedienungsanleitung

Selec
Selec TC544C Bedienungsanleitung