Optek AS56 Series Bedienungsanleitung

Instruction Manual
optek-sensors AS56
Version 04.2010_1.2US
PN: 1004-2011-02 (-52)
optek-Danulat GmbH
Emscherbruchallee 2
45356 Essen
Phone: +49-(0)201-63409-0
Fax: +49-(0)201-63409-999
E-Mail: inf[email protected]e
Internet: www.optek.com

Preface
optek-sensors AS56, Version 04.2010_1.2US, 15.04.2010
www.optek.com
Preface
This instruction manual is written to assist the user in proper procedures for
trouble-free operation.
Itis explicitlypointed out thatoptek-Danulat GmbH assumes no responsibilityfor
loss or damage caused due to improper use of this instruction manual or
products described herein.
This manual is protected by copyright. However, the user may produce copies
and translations if required for correct operation of the products.
On request, this manual is available in other languages as well as in digital
format (Acrobat®Reader 7.0 required).
Our products are being continuously improved. Technical data is subject to
change without notice.
Essen, January 2010

Preface
optek-sensors AS56, Version 04.2010_1.2US, 15.04.2010
www.optek.com
For further inquiry, feel free to contact us or our distributing partners at
any time:
Germany
optek-Danulat GmbH
Emscherbruchallee 2
45356 Essen / Germany
Phone: +49-(0)201-63409-0
Fax: +49-(0)201-63409-999
E-Mail: info@optek.de
Netherlands
optek-Danulat bv
Grote Brugse Grintweg 12a
4005 AH Tiel / Netherlands
Phone: +31 -344 -683800
Fax: +31 -344 -653950
E-Mail: info@optek.nl
USA
optek-Danulat Inc.
N118 W18748 Bunsen Drive
Germantown WI 53022 / USA
Phone: +1 262 437 3600
Toll free call: +1 800 371 4288
Fax: +1 262 437 3699
E-Mail: info@optek.com
Singapore
optek-Danulat Pte. Ltd.
25 Int’l Business Park
#05-109-f German Centre
Singapore 609916
Phone: +65 6562 8292
Fax: +65 6562 8293
E-Mail: info@optek.com.sg
Russian Federation
optek-Danulat GmbH
Liter A, Room 911, 26-N
Kolomjazhskij Prospekt 33
197341 St. Petersburg
Phone: +7 963 342 25 66
E-Mail: info@optek-danulat.ru
Internet: http://www.optek.com

Table of contents
- I -
optek-sensors AS56, Version 04.2010_1.2US, 15.04.2010
www.optek.com
Table of contents
Preface
1Using the instruction manual .................................................................................................1
1.1 Validity of the instruction manual......................................................................................... 1
1.2 Pictograms and signal words............................................................................................... 2
1.3 Note regarding return of the sensor..................................................................................... 3
2Intended use ............................................................................................................................4
3Description of AS56-F / AS56-N sensors ..............................................................................5
4Technical data and exploded views ......................................................................................7
4.1 Dimension AS56-F / AS56-N sensor.................................................................................... 9
4.2 Accessories weld-in port AS25 .......................................................................................... 10
4.3 Accessories Varivent adapter port AS25-G60.................................................................... 12
4.4 Accessories Clamp adapter port AS25-G60 ...................................................................... 13
4.5 Accessories optek T-pieces for pipe DIN 11850................................................................ 14
4.6 Accessories optek T-pieces for pipe OD............................................................................ 15
4.7 Accessories sealing flange AS25....................................................................................... 16
4.8 Exploded view of AS56-F / AS56-N sensor........................................................................ 17
5Installation .............................................................................................................................18
5.1 General installation instructions......................................................................................... 18
5.2 Installation of the sensor.................................................................................................... 20
5.3 Airpurge............................................................................................................................. 22
6Connection to converter C4000 ...........................................................................................23
7Connection to converter 156 ................................................................................................27
8Faults ......................................................................................................................................30

Table of contents
- II -
optek-sensors AS56, Version 04.2010_1.2US, 15.04.2010
www.optek.com
9Maintenance ...........................................................................................................................32
9.1 Preventive maintenance .................................................................................................... 32
9.2 Exchange of lamp module ................................................................................................. 33
9.3 Return to operation after the exchange of lamp module .................................................... 35
9.4 Spare parts and accessories ............................................................................................. 36
9.4.1 Lamp module ...........................................................................................................36
9.4.2 Installation Kit AS .....................................................................................................36
9.4.3 Gaskets (not wetted) ................................................................................................36
9.4.4 Gaskets (wetted)* ....................................................................................................36
9.4.5 Screw sets ...............................................................................................................37
9.4.6 Small part sets .........................................................................................................37
9.4.7 Installation material ..................................................................................................37
9.4.8 Accessories ..............................................................................................................37
9.4.9 Accessories – cables ...............................................................................................38
10 Disposal .................................................................................................................................39
11 Appendix ................................................................................................................................40
11.1 Declaration of conformity................................................................................................... 41
11.2 TÜV NORD CERT GmbH "GS-mark"................................................................................. 42
11.3 QM system certificate........................................................................................................ 45
11.4 Decontamination declaration ............................................................................................. 46
11.5 Response via fax............................................................................................................... 48

Using the instruction manual
- 1 -
optek-sensors AS56, Version 04.2010_1.2US, 15.04.2010
www.optek.com
1 Using the instruction manual
1.1 Validity of the instruction manual
This instruction manual is valid for AS56-F / AS56-N sensors. Abbreviations
mean the following sensor options:
• F color sensor (wavelength application specific)
• N near infrared (wavelength range 730 - 970 nm)
Follow the instruction manual for every operation. If the sensor is not used as
described in this instruction manual, your safety and the sensor function could
be affected.
To keep up reliability of the product, enhance its life cycle and avoid down times,
you have to follow the instructions given in this manual.
Furthermore, please follow the existing accident prevention and environmental
protection instructions, as well as recognized technical instructions for safe and
professional working.

Using the instruction manual
- 2 -
optek-sensors AS56, Version 04.2010_1.2US, 15.04.2010
www.optek.com
1.2 Pictograms and signal words
Important information in this instruction manual is marked with the following
pictograms:
Danger!
This pictogram indicates immediate danger to life and health of persons.
The text next to the symbol gives information on how to avoid bodily injuries.
If the possible cause of risk can be specified, the corresponding pictogram
preceeds instructions:
Danger!
Electrical voltage.
This pictogram indicates danger due to electrical voltage.
Caution!
This pictogram indicates information on how to avoid material damage.
Note!
This pictogram indicates instructional or general advice.

Using the instruction manual
- 3 -
optek-sensors AS56, Version 04.2010_1.2US, 15.04.2010
www.optek.com
1.3 Note regarding return of the sensor
In the appendix of this instruction manual you find a declaration regarding the
decontamination of the sensor. Please fill out that declaration and add it to
sensor packaging when you return the sensor.
Note!
optek can only accept the returned sensor with the filled out and signed
decontamination declaration enclosed in the package.

Intended use
- 4 -
optek-sensors AS56, Version 04.2010_1.2US, 15.04.2010
www.optek.com
2 Intended use
The optek-sensors AS56 and their variants are to be applied only as absorption
sensors for liquids and gases in inline applications according to the technical
data.
The use of the sensors in hazardous locations is prohibited.
You can purchase flameproof sensors for hazardous locations from optek. For
these sensors, special instruction manuals are delivered with the sensor.
Unauthorizedconstructionalchanges, additionalfittings orrebuildings regarding
the sensor are prohibited. The only exception are rebuildings into one of the
variants listed in the chapter "Validity of the instruction manual". Changes to and
interference with the converter program are prohibited as well.
To lay sensor cables underground without protection is prohibited.
The manufacturer is not liable for damage resulting from use contrary to
intended use.
Following this instruction manual is part of the intended use.

Description of AS56-F / AS56-N sensors
- 5 -
optek-sensors AS56, Version 04.2010_1.2US, 15.04.2010
www.optek.com
3 Description of AS56-F / AS56-N sensors
This sensor is a high precision absorption sensor designed for direct installation
into pipelines and vessels. It is of compact and robust construction with a
measuring segmentoptimized withrespectto flow andsterilerequirements.Two
different optical path lengths in combination with an extensive range of
accessories offer maximum flexibility for adaptation to the process.
Fig. 1 AS56
The following are the main sensor components:
Fig. 2 Schematic AS56
1. Optical path length (OPL)
2. Sapphire window
3. Lamp
4. Optics module with filter
5. Detector
A precisely defined, constant light beam penetrates the process medium. A
hermetically sealed silicon photodiode measures intensity of incoming and
optically filtered light and supplies the converter with it in form of photocurrent.
12
2345
Andere Handbücher für AS56 Series
1
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Andere Optek Sicherheitssensor Handbücher