OutBack Power HUB 10.3 Bedienungsanleitung

Quick Start Guide
900-0154-01-00 REV B.vsd\2014-02-18
©2013 OutBack Power Technologies. All Rights Reserved.
HUB 10.3
Contact Technical Support:
Telephone: +1.360.618.4363
Email: [email protected]
Website: www.outbackpower.com
IMPORTANT:
Not intended for use with
life support equipment.
OutBack Power and the OutBack Power logo are trademarks owned and used by
OutBack Power Technologies, Inc. The ALPHA logo and the phrase “member of
the Alpha Group” are trademarks owned and used by Alpha Technologies.
These trademarks may be registered in the United States and other countries.
A Positions
3.
Changing Jumpers
2.
4a.
4b.
1.27"
(3.2 cm)
10.63" (27 cm)
6.18"
(15.7 cm)
4.23"
(10.7 cm)
9.24" (23.5 cm)
Dimensions
Mounting
#10 x ½” Screws x 2
HUB10.3 HUB Wiring Cover
Cable, CAT5e, 3' (1 m) x 2
Cable, CAT5e, 6' (2 m) x 3
Parts List
Cable, CAT5e, 10' (3 m) x 4
Shutter Bushing x 2
Snap Bushing x 2
2.
1.
3.
1" recommended
1. Back of HUB 10.3
4c.
B Positions
Used for three-phase OutBack stacking with
FX, VFX, FX(E) or VFX(E) inverters.
For these applications, place only two jumpers
in the positions noted in the photograph
and the diagram.
Remove all remaining jumpers. No others are
used for this configuration.
Searching for Devices
Found
HUB10.3 Sub-phase Master
Jumper position identified by
MATE3 on power-up:
Searching for Devices
Found
HUB10.3
Used for Subphase Master stacking in FX
and GS inverters (both three-phase and
series configurations).
For these applications, place all jumpers
in the positions noted in the photograph
and the diagram.
NOTE: This option requires MATE3
firmware revision 002.013.000 or higher.
Jumper position identified by
MATE3 on power-up:
Searching for Devices
Found
HUB10.3
Jumper position identified by
MATE3 on power-up:
This is the factory-installed initial position.
Used for classic series, OutBack series, and
parallel stacking. Also used for three-phase
OutBack stacking with models GVFX(E) and
GTFX(E) .
For these applications, place all jumpers in
the positions noted in the photograph and
the diagram.

Stacking (Series) HUB 10.3
Stacking (Parallel) HUB 10.3
900-0154-01-00 REV B.vsd\2014-03-03
©2013 OutBack Power Technologies. All Rights Reserved. 900-0154-01-00 REV B.vsd\2014-03-03
©2013 OutBack Power Technologies. All Rights Reserved.
Series Stack (OutBack)
Up to 10 inverters or other devices; requires balancing transformer
Master inverter and half of the Slave inverters use common output AC bus (L1)
The remaining Slave inverters use a separate common AC bus (L2)
Master inverter is always active; regulates output based on load;
can power both L1 and L2 buses using balancing transformer
Slave inverters remain in Power Save mode; Master activates
any Slave inverters for either L1 or L2 based on load
Series Stack (Classic)
2 inverters; up to 8 other devices
Master and single Slave inverter use separate output AC buses
(L1 and L2)
Both inverters always active
(no Power Save mode);
outputs are loaded independently
but output regulation is controlled
by load on Master
1st
MATE
X
10 9 8 7 6 5 4 3 2 1
Port 1
Stack Mode Master or 1-2phase Master
Parallel Stack
Up to 10 inverters or other devices
All inverters use common AC output bus
Master inverter always active; regulates power output based on load
Slave inverters remain in Power Save mode; Master activates
Slave inverters based on load
Slave (port 2, port 3, etc.)
Jumper position
(see step 4b
on front page)
or
(with
FX-class
inverter)
FX / VFX (includes
J, M, N Series)
GTFX
GVFX
GTFX (LA Series)
GVFX (LA Series)
Models
GFX
Ports 2 to 10 can be assigned to either
OB Slave L1 or OB Slave L2;
equal numbers of inverters should be
assigned to each side
Port 1
Stack Mode Master or 1-2phase Master
Port 2
Stack Mode OB Slave L1
or
OB Slave L2
FX / VFX (includes
J, M, N Series)
Models
Master (port 1 only)
Port 2
Stack Mode Slave or OB Slave L1
Port 1
Stack Mode Master or 1-2phase Master
Master (port 1 only)
Slave (port 2)
Jumper position
(see step 4b
on front page)
10987654321X1st
MATE
Master (L1)
Jumper
position
(see step 4b
on front page)
MasterSlaveSlaveSlaveSlaveSlaveSlaveSlave
Slave (L2)
Port 2
Stack Mode Classic Slave
or
or
Master (port 1 only)
Slave (port 2)
Models
FX / VFX (all series,
including E, J, M, N,
and W)
GS8048A
GFX
GFX (E Series)
GTFX (E Series)
GVFX (ESeries)
GS4048A
GS7048E
GS3548E
GS8048
Split-phase
inverters:
Single-phase
inverters:
Output
Single-phase output
Split-phase output
Single-phase
inverters: Split-phase output
Output
Single-phase
inverters: Split-phase output
Output
10987654321X1st
MATE
Slave (L2) Slave (L2) Slave (L2) Slave (L2) Slave (L2) Slave (L1) Slave (L1) Slave (L1)Slave (L1) Master (L1)

Stacking (Three-Phase) HUB 10.3
Stacking (Three-Phase) HUB 10.3
900-0154-01-00 REV B.vsd\2014-03-03
©2013 OutBack Power Technologies. All Rights Reserved. 900-0154-01-00 REV B.vsd\2014-03-03
©2013 OutBack Power Technologies. All Rights Reserved.
Ports 2 to 10 can be assigned any 3phase OB Slave
stack mode; no more than 3 inverters per mode
Three-Phase Stack
Up to 9 inverters; 1 other device
Master and two Slave inverters use separate output AC buses (A, B,and C)
All inverters always active (no Power Save mode);
outputs are loaded independently but output regulation
is controlled by load on Master
Three-Phase Stack
3 inverters; up to 7 other devices
Master and two Slave inverters use separate output AC buses (A, B,and C)
All inverters always active (no Power Save mode);
outputs are loaded independently but output regulation
is controlled by load on Master
Models
FX / VFX (all series,
including E, J, M, N,
and W)
Jumper position
(see step 4c
on front page)
A
C
B
Single-phase inverters:
Three-phase output
PHASE A
PHASE B
PHASE C
Output
Port 1
Stack Mode Master
Slave B (port 4 only)
or
Master (port 1 only)
Port 4
Stack Mode 3ph Slave
1098 765 4321
X
1st MATE
Slave C (port 5 only)
Port 5
Stack Mode 3ph Slave
A
C
B
Single-phase inverters:
Three-phase output
PHASE A
PHASE B
PHASE C
Output Jumper position
(see step 4b
on front page)
GTFX (E Series)
GVFX (E Series)
Models
or
109 8765 4 321
X
1st MATE
or
Master (port 1 only)
Slave A, B, or C (port 2, port 3, etc.)
A
C
B
Port 1
Stack Mode Master
Port 2
Stack Mode 3phase OB Slave A
3phase OB Slave B
3phase OB Slave C
Slave (C) Slave (B) Master (A)
Slave (B)Slave (B) Slave (B)
Slave (C) Slave (C)Slave (C)
Master (A)Slave (A)Slave (A)

Slave (A) Slave (A)
Master (A)
Subphase Master (C)
Slave (C)Slave (C)
or
Three-Phase Stack (Subphase Master)
Up to 9 inverters (ports 1 to 9); 1 other device (port 10); MATE3 only
Master inverter (required on port 1) and up to two Slave inverters (ports 3 & 3) use Phase A output AC bus
Subphase Master inverter (required on port 4) and up to two Slaves (ports 5 & 6) use Phase B output AC bus
Subphase Master inverter (required on port 4) and up to two Slaves (ports 8 & 9) use Phase C output AC bus
Phase A, B, and C Slave inverters should beequal in number; Slave selection screen may display Slave but
could display OB Slave L1 depending on model
Master and Subphase Masters are always active; each type of Master regulates output based on its own load
Slave inverters remain in Power Save mode; the Master activates Phase A Slave inverters based on its load,
while the Subphase Masters independently activate Phase B or C Slave inverters based on their own loads
Rev 002.013.000
or higher
Port 1
Stack Mode Master
Port 2
Stack Mode Slave
or
OB Slave L1
Port 4
Stack Mode B Phase Master
or
3p Classic B
Port 7
Stack Mode C Phase Master
or
3p Classic C
Also ports 3, 5, 6, 8, and 9
Three-Phase Stack
Up to 9 inverters; 1 other device (MATE or MATE3)
Subphase Master (B)
Slave (B)
Slave (B)
HUB 10.3
Stacking (Subphase Master) HUB 10.3
900-0154-01-00 REV B.vsd\2014-03-03
©2013 OutBack Power Technologies. All Rights Reserved. 900-0154-01-00 REV B.vsd\2014-03-03
©2013 OutBack Power Technologies. All Rights Reserved.
GFX
Models
Series Stack (Subphase Master)
Up to 8 inverters (ports 1 to 4, 7 to 10); 2 other devices (ports 5, 6); No balancing transformer required
Master inverter and half of the Slave inverters use common output AC bus (L1); ports 2 to 4 are L1 slaves
Subphase Master inverter and half of the Slave inverters use a separate common AC bus (2); ports 8 to 10
are L2 Slave inverters despite the screen selection (OB Slave L1)
Port 7 is the L2 Subphase Master despite the screen selection (Classic Slave); this port is required
regardless of the number of Slave inverters
Master and Subphase Master are always active; each type of Master regulates output based on its own load
Slave inverters remain in Power Save mode; Master activates L1 Slave inverters based on its load, while the
Subphase Master independently activates L2 Slave inverters based on its own load
Port 1
Stack Mode Master
Port 2
Stack Mode OB Slave L1
Also ports 3, 4, 8, 9, and 10
Port 7
Stack Mode Classic Slave
or
Single-phase
inverters: Split-phase output
Output
10 9 8 7654 3 2 1
X
1st MATE
Jumper position
(see step 4a
on front page)
Master (port 1 only)
Slave (port 2)
Subphase Master (port 7)
Stacking (Subphase Master)
GS7048E
GFX
GFX (E Series)
Models
GS3548E A
C
B
Single-phase inverters:
Three-phase output
PHASE A
PHASE B
PHASE C
Output
Jumper position
(see step 4a
on front page) Master (port 1 only)
Slave (port 2)
Subphase Master (port 7)
Subphase Master (port 4)
10 9 8 7654321
X
1st MATE
A
C
B
Slave (L2) Slave (L2) Slave (L2) Subphase
Master (L2) Slave (L1) Slave (L1) Slave (L1) Master (L1)
Beliebte Konferenzsystem Handbücher anderer Marken

Kramer
Kramer VIA GO Bedienungsanleitung

AVT
AVT MAGIC AC1 Go Bedienungsanleitung

ProSoft Technology
ProSoft Technology AN-X4-AB-DHRIO Bedienungsanleitung

Sony
Sony PCS-I150 Bedienungsanleitung

Middle Atlantic Products
Middle Atlantic Products VTC Series Bedienungsanleitung

Prentke Romich Company
Prentke Romich Company Vanguard Plus Leitfaden