Penguin Computing Arctica 4804iq Series Bedienungsanleitung

Arctica 4804iq Series switch Installation Guide
Arctica 4804iq
Series switch Installation Guide
Version 1.1
2016-04-20

Arctica 4804iq Series switch Installation Guide
contents
1.Introduction ................................................................................................1
1.1.Product Brief......................................................................................................1
1.2.Description of Hardware....................................................................................1
1.2.1.Front Panel...............................................................................................1
1.2.2.Back Panel................................................................................................2
1.3.Status LEDs........................................................................................................2
1.4.Port Description.................................................................................................4
1.5.Power Supply Module........................................................................................4
1.6.Fan Module.........................................................................................................5
1.7.System Specifications.......................................................................................5
2.Installation Notice.......................................................................................1
2.1.Environmental Requirements ..........................................................................1
2.1.1.Dust and Particles....................................................................................1
2.1.2.Temperature and Humidity......................................................................2
2.1.3.Power Supply...........................................................................................3
2.1.4.Preventing Electrostatic Discharge Damage.........................................3
2.1.5.Anti-interference......................................................................................3
2.1.6.Rack Configuration..................................................................................4
2.2.Installation Notice..............................................................................................4
2.3.Security Warnings..............................................................................................4
3.Device Installation......................................................................................1
3.1.Installation Preparation.....................................................................................1
3.1.1.Verify the Package Contents...................................................................1
3.1.2.Required Tools and Utilities....................................................................1
3.2.Device Installation .............................................................................................1
3.2.1.Installing the Switch................................................................................1
3.2.2.Installing the Power Supply Module.......................................................2
3.2.3.Installing the Fan .....................................................................................4
3.2.4.Connecting Console................................................................................5
3.2.5.SFP/SFP+ Transceiver Installation.........................................................6
3.2.6.Copper Cable/Fiber Cable Connection ..................................................6
3.2.7.AC Power Supply Connection ................................................................7
3.2.8.Checking the Switch................................................................................8

Arctica 4804iq Series switch Installation Guide Chapter 1 Introduction
1.Introduction
1.1.Product Brief
Arctica 4804iq series switches are Celestica to launch the next generation of
switching,With high reliability、multiple redundancy etc. It provides the cogent network
sustentation for 1000Mb connecting to 10Gb scheme in data center and distripark
network.
Arctica 4804iq figures as follow:
Figure 1-1 Arctica 4804iq Series Switch Figures
1.2.Description of Hardware
1.2.1.Front Panel
1. Front Panel Diagram
The front panel descriptions of Arctica 4804iq series switch in the following table.
Table 1-1 The front panel descriptions of Arctica 4804iq series switch
Type
RJ45 port
SFP+ port
10/100/1000Base-T
ETHERNET port Console port
USB2.0
interface
Arctica 4804iq
48
4 1 1 1

Arctica 4804iq Series switch Installation Guide Chapter 1 Introduction
The front panel of Arctica 4804iq is shown below:
Figure 1-2 Front Panel of Arctica 4804iq
2. Console description
Arctica 4804iq series switches provide a RJ-45 serial console port, the user perform
the local and telnet configuration through this port.
The console port supports asynchronous mode, set the data bit as 8, the stop bit as
1, the parity bit as none, the default baud rate as 115200bps.
1.2.2.Back Panel
The back panel of Arctica 4804iq includes 2 alternating current of 220V (it provides
redundancy backups) and 3 fan rabbets.
Fig
1-3
Back panel of
Arctica 4804iq
(standard configuration)
Fig 1-4 Back panel ofArctica 4804iq (full in)
1.3.Status LEDs
The indicator light on front panel of Arctica 4804iq has 48 RJ45 port indicator light, 4
SFP+ port indicator light, 2 power supply indicator light and system automatic diagnoses
LED. They are shown below and described in the following table.
Table 1-2 The explanation of indicator light ofArctica 4804iq series switch

Arctica 4804iq Series switch Installation Guide Chapter 1 Introduction
Indicator light Panel sign State Meanings
Power supply
indicator light P-1 / P-2
Green light
always on Power supply module move
normally.
Amber light
always on Power make a mistake
Put out No power supply
System
automatic
diagnoses LED STAT
Green light
always on System running normal.
Green light winks System booting
Work mode
indicator light MAST
Green light
always on Master mode
Amber light
always on Slave mode
Table 1-3 The explanation of the port indicator light
Indicator light Panel sign State
ETHERNET port
Link light (right)
Green The port is under the connection state of 10M,
100M o
r
1000M.
Green winks The port is transmitting data
Put out No connection or fail to connect.
Indicator light of
SFP+ port
Green The port is unde
r
the connection state of 1G/10G.
Green Wink The port is transmittin
g
data.
Put out No connection or fail to connect.
Indicator light of
RJ45 port
Green The port is unde
r
the connection state of 1G.
Amber The port is under the connection state of
10M/100M.
Green Wink The 1G port is transmitting data.
Amber Winks The 10M/100M port transmitting data.
Put out No connection or fail to connect.

Arctica 4804iq Series switch Installation Guide Chapter 1 Introduction
1.4.Port Description
Arctica 4804iq provides 48 RJ45 ports and 4 10Gb SFP+ ports.
Each port description in the following:
Table 1-4 Arctica 4804iq series port description
Port mode Spec
RJ-45 port 10/100/1000Mbps auto negotiation
MDI/MDI-X cable mode auto negotiation
5 kinds of UTP: 100 m
SFP+
SFP-SX-L transceiver
SFP-LX-L transceiver
SFP-LX-20-L transceiver
SFP-LX-40 transceiver
SFP-LH-70-L transceiver
SFP-LH-120-L transceiver
SFPP-10G-SR transceiver
SFPP-10G-LR transceiver
SFPP-10G-ER transceiver
SFPP-10G-ZR transceiver
Arctica 4804iq series swich provide 4 SFP+ ports and support the SFP+ cable(0.5M-
7M). It enhances the flexibility of the network.
1.5.Power Supply Module
The following picture is the power supply module of Arctica 4804iq. The whole
appearance sketch map is below:

Arctica 4804iq Series switch Installation Guide Chapter 1 Introduction
Fig 1-5 The sketch map of PSM
Arctica 4804iq series switch has one PSM in standard configuration. When two
power supplies are at their position, it provides redundancy backups.
The maximum power is 200W, the import is 90VAC~264VAC/47HZ~63HZ and the
export is 12V +/- 5%. There is a fan and a handle for sticking in or pulling out the module
on the back of the power supply. The power supply module supports the hot plug.
1.6.Fan Module
Arctica 4804iq series fan module. The whole appearance sketch map is below:
Fig 1-6 The sketch map of Fan module
Arctica 4804iq switch has 3 Fan modules in standard configuration. The rotate speed
of fan adjusts itself adapt to the system temperature, The fan module supports the hot
plug
1.7.System Specifications
Table 1-6 System Specifications ofArctica 4804iq series
Type
Attribute Arctica 4804iq
Dimension(W * H * D) (mm) 320×434×44
Weight 5.6 kg (standard: one power)

Arctica 4804iq Series switch Installation Guide Chapter 1 Introduction
Fixed Port 48 RJ45 ports; 4 SFP+ ports
Management Port 1 RJ-45 serial console port
1 RJ_45 managemen Ethernet port
Powe
r
Input 90~264VAC(47~63Hz)
System Consumption 85.2W
Operating Temperature 0°C~45°C
Stora
g
e Temperature -40°C~70°C
Relative Humidity 5%~85%, no condensate

Arctica 4804iq Series switch Installation Guide Chapter 2 Installation Notice
2.Installation Notice
To ensure the proper operation of Arctica 4804iq series and your physical security,
please read carefully the following installation guide.
2.1.Environmental Requirements
■The switch must be installed in a clean area. Otherwise, the switch may be damaged
by electrostatic adherence.
■Maintain the temperature within 0 to 45 °C and the humidity within 5% to 85%, non-
condensing.
■The switch must be put in a dry and cool place. Leave sufficient spacing around the
switch for good air circulation.
■The switch must work in the range ofAC power input: 90 ~ 264VAC (47/63Hz).
■The switch must be well grounded in order to avoid ESD damage and physical injury
of people.
■The switch should avoid the sunlight perpendicular incidence. Keep the switch away
from heat sources and strong electromagnetic interference sources.
■The switch must be mounted to a standard 19’’ rack or placed on a clean level
desktop.
2.1.1.Dust and Particles
Dust is harmful to the safe operation of Arctica 4804iq series. Dust can lead to
electrostatic adherence, especially likely under low relative humidity, causing poor
contact of metal connectors or contacts. Electrostatic adherence will result in not only
reduced product lifespan, but also increased chance of communication failures. The
recommended value for dust content and particle diameter in the site is shown below:
Max Diameter (µm) 0.5 1 3 5
Max Density
(particles/m³) 1.4×1057×1052.4×1051.3×105
Table 2-1 Environmental Requirements: Dust
In addition, salt, acid and sulfide in the air are also harmful to the switch. Such
harmful gases will aggravate metal corrosion and the aging of some parts. The site
should avoid harmful gases, such as SO2, H2S, NO2, NH3and Cl2, etc. The table below
details the threshold value.

Arctica 4804iq Series switch Installation Guide Chapter 2 Installation Notice
Gas Average (mg/m³) Max (mg/m³)
SO20.2 1.5
H2S 0.006 0.03
NO20.04 0.15
NH30.05 0.15
Cl20.01 0.3
Table 2-2 Environmental Requirements: Particles
2.1.2.Temperature and Humidity
Although the switch is designed to use 3 fans, the site should still maintain a
desirable temperature and humidity. High-humidity conditions can cause electrical
resistance degradation or even electric leakage, degradation of mechanical properties
and corrosion of internal components. Extreme low relative humidity may cause the
insulation spacer to contract, making the fastening screw insecure. Furthermore, in dry
environments, static electricity is liable to be produced and cause harm to internal
circuits. Temperature extremes can cause reduced reliability and premature aging of
insulation materials, thus reducing the switch’s working lifespan. In the hot summer, it is
recommended to use air-conditioners to cool down the site. And the cold winter, it is
recommenced to use heaters.
The recommended temperature and humidity are shown below:
Temperature: Relative humidit
y
Long term condition Short term condition Long term condition Short term condition
15 ~ 30°C 0 ~ 45°C 40 ~ 65% 5 ~ 85%
Table 2-3 Environmental Requirements: Temperature and Humidity
Caution!
A sample of ambient temperature and humidity should be taken at 1.5m above the
floor and 0.4m in front of the switch rack, with no protective panel covering the front and
rear of the rack. Short term working conditions refer to a maximum of 48 hours of