Pepperl+Fuchs Ecom Lite-Ex PL 30e Bedienungsanleitung

1
Operating Instructions | Bedienungsanleitung
Notice d‘utilisation | Istruzioni per l‘uso
Instrucciones de uso | Manual de instruçoes
Lite-Ex®PL 30e
Zone 0 / 20

2
English Page 3
Deutsch Seite 13
Français Page 23
Italiano Page 33
Español Página 43
Portoguês Sida 53

3
Content
1. Application ............................................................................................. 4
2. Safety instructions................................................................................. 4
3. Faults and damage ................................................................................ 4
4. Safety regulations.................................................................................. 5
4.1. Special requirements for use in ex-hazardous area.......................... 5
5. Safety instructions................................................................................. 5
6. Ex-data................................................................................................... 6
6.1. ATEX .................................................................................................... 6
6.2. IECEx ................................................................................................... 6
7. Technical data ........................................................................................ 6
8. Function descripation / operating information ..................................... 7
8.1. Lite-Ex PL 30e components................................................................ 8
8.2. Getting started .................................................................................... 8
8.3. Battery replacement........................................................................... 8
8.4. Cleaining the rotary switch................................................................. 9
8.5. Lamp replacement.............................................................................. 9
8.6. Replacing the spare disc..................................................................... 9
9. Repairs ................................................................................................... 10
10. Cleaning, maintenance and storage.................................................... 10
11. Disposal................................................................................................ 11
12. Warranty and liability........................................................................... 12
13. EU Declaration of Conformity.............................................................. 12
14. EU-type examination certicate .......................................................... 12
Note:
The current operating instructions, the EU Declaration of Conformity and
the EU-type examination certicate can be downloaded from the relevant
product page at www.ecom-ex.com, or alternatively they can be requested
directly from the manufacturer.

4
1. Application
The Lite-Ex PL 30e is a LED- torch / ashlight (according directive 2014/34/
EU, ATEX) for industrial use in potentially explosive areas classied as zone
0 and 20 (in accordance with directive 1999/92/EC) and the IECEx System.
2. Safety instructions
These operating instructions contain information and safety regulations
which are to be observed without fail for safe operation in the described
conditions. Non-observance of this information and these instructions can
have serious consequences or it may violate regulations.
Please read these operating instructions carefully before starting to use
the unit! In case of any doubt (in the form of translation or printing errors)
the English language operating instructions shall apply.
3. Faults and damage
If there is any reason to suspect that the safety of the unit has been impaired,
it must be withdrawn from use and removed immediately from the Ex-area.
Measures must be taken to prevent it from being restarted accidentally.
We recommend that the unit is returned to the manufacturer for inspection.
The safety of the unit may be compromised, if, for example:
• there is visible damage to the housing.
• the unit has been subjected to excessive loads.
• the unit has been improperly stored.
• the unit has been damaged in transit.
• unit markings or inscriptions are illegible.
• malfunctions occur.
• permitted limit values have been exceeded.

5
4. Safety regulations
Use of this unit assumes that the user observes the conventional safety
regulations and has to read the certicate in order to eliminate faulty
operation of the unit.
The following additional safety regulations must also be observed:
• The unit must not be opened within the Ex-area.
• The batteries must only be changed outside the Ex-area.
• Additional or spare batteries must not be carried in the Ex-area.
• Only type-approved batteries types may be used.
• Only spare sealing rings and discs of ecom instruments are allowed.
• Only accessories approved by ecom instruments GmbH may be used.
• Prevent the unit from coming into contact with aggressive acidic or
alkaline solutions.
• Do not open the inside torch head.
4.1. Special requirements for use in ex-hazardous area
• Storing of the torch is prohibited!
• After changing the batteries or the sealing rings always check to make
sure that the sealing rings and threads are clean and in good condition.
• Before using the lamp in the Ex-hazardous area and in order to ensure
the IP rating, please check that all parts of the unit are hand tightened up
to the stop – being careful not to over-tighten.
5. Safety instructions
Caution! Strong light may blind other people.
• Do not look directly into the light.
• Do not shine the light directly into the eyes of other people.

6
6. Ex-data
6.1. ATEX
EU type examination certicate : EPS 16 ATEX 1 170 X
Ex-marking: †II 1 G Ex ia op is IIC T4 Ga IP65
†II 1 D Ex ia IIIC T130° Da IP65
Ambient temperature: -20°C ≤ Ta ≤ +50°C
Approved for Zone 2,1 and 0, device group II, explosion group IIC,
temperature class T4.
Approved for zone 22, 21 and 20, device group II, explosion group IIIC,
maximum Temperature 130°C.
6.2. IECEx
IECEx Certicate of Conformity no.: IECEx EPS 16.0074X
Ex-marking: Ex ia op is IIC T4 Ga IP65
Ex ia IIIC T130°C Da IP65
Ambient temperature: -20°C ≤ Ta ≤ +50°C
Approved for Zone 2, 1 and 0, device group II, explosion group IIC,
temperature class T4.
Approved for zone 22, 21 and 20, device group II, explosion group IIIC,
maximum Temperature 130°C.
7. Technical data
Ambient temperature: -20°C ≤ Ta ≤ +50°C
Storage temperature: -30°C … +60°C (without batteries)
Battery / power supply: 3 x LR14 (see table with approved batteries)
Lamp: 1 high-performance LED (3 watt)
Luminosity: 5000 lx (at a distance of 1 m)
Luminous ux: 204 lumens
Operating time: > 48 hours (continuous operation)

7
Dimensions: approx. 220 x 40/45 mm
Weight: approx. 550 g (with batteries)
IP-rating: IP 65
ESD protection: Antistatic housing
CE-designation: 0102
Approved battery types:
Manufacturer Type (LR14)
Panasonic Pro Power
Panasonic Powerline
Eveready Energizer Energizer A93
Varta 4014
Energizer E93
Approved sealing rings and discs:
Manufacturer Type
ecom sealing rings type PL30 (complete set)
ecom spare disc type PL30
8. Function descripation / operating information
Please take the time to carefully read through these operating instructions
to ensure that you are familiar with all of the functions of your Lite-Ex
PL 30e and know how to use all of the functions. For your own safety and
information please read through the information on the following pages.

8
8.1. Lite-Ex PL 30e components
Body of torch
Sealing rings
Housing head
Twist ring
Battery compartment
Alignment screw
Spare disc
Torch head
39x1,5
35x2
30x2
Illustration 1
8.2. Getting started
In order to be able to use the torch in the Ex-area, you must rst check
that the outer housing head and body are screwed on completely. After this
has been done, you can switch on the torch by turning the yellow twist ring
slightly in a clockwise direction. The enclosed batteries have to be inserted
rst in the device (see section 8.3).
8.3. Battery replacement
When the brightness is no longer satisfactory, the batteries should be
replaced. It is strongly recommended that all three batteries are be replaced
together. When replacing the batteries, only use approved battery types
(see table of approved battery types in section 7: Technical data).
To replace the batteries, hold on to the housing head and the twist ring,
and turn the body of the torch anticlockwise until it comes off. Take the
used batteries out of the battery compartment, observing correct polarity
and replace them with new ones. After you have inserted the new batteries
screw the body of the torch back on. Make sure that torch components are
screwed together securely before switching the torch on.

9
Battery replacement
• Only use approved battery types. See table in section 7: Technical data.
• Always replace all of the batteries together.
• Make sure that the polarity of the inserted batteries is correct.
• Please ensure that all used batteries are properly disposed of in an
environmentally friendly manner.
• After changing the batteries or the sealing rings always check to make
sure that the sealing rings and threads are clean and in a good condition.
8.4. Cleaining the rotary switch
A non-contacting rotary switch is used to switch on the Lite-Ex PL 30e (see
description above). Dirt or moisture does not effect the function. The rotary
switch is easy to clean if excessive amounts of dirt and grime have made it
difcult to turn. First take off the torch body and remove the batteries (see
section 8.3 Battery replacement). Remove the rotary switch by sliding it off
the back of the torch, and then clean the switch. When putting the rotary
switch back on, make sure that the arrow marks on the ring line up with the
alignment screw on the bottom part of the torch head (see picture 1). Then
re-insert the batteries, and screw the body of the torch back on.
8.5. Lamp replacement
The Lite-Ex PL 30e is equipped with an extremely long-lasting LED lamp.
Replacing the LED is normally not required. If, however, the torch is
defective or the brightness of the torch has diminished, it should be sent to
ecom instruments for inspection or repair. Under no circumstances should
you attempt to open the torch head. Manipulating the torch head or LED on
your own poses a risk to the safety of the torch and is not permitted.
8.6. Replacing the spare disc
The torch head is protected by the housing head that surrounds it as well
as an additional disc, which is positioned over the opening where the beam
is emitted. The disc is made of high-quality material. Should, however, the
disc break, it is possible to replace it. To replace the disc, hold on to the
body of the Lite-Ex PL 30e and the twist ring, and carefully unscrew the
housing head by turning it anticlockwise. Clean the housing head thoroughly

10
to remove any remaining pieces, and check the sealing ring for damage.
After this has been done, you can install a new disc and, if necessary, new
sealing rings. Only spare sealing rings of ecom instruments are allowed.
The sealing ring is positioned between the housing head and the disc (see
picture 1). When putting the housing head back on, ensure that the seal is
positioned properly on the disc. After installation, you should not be able
to see any part of the sealing ring through the opening where the beam is
emitted. If the inside of the torch head or lens is also damaged, the torch
should be sent to the manufacturer for repair.
9. Repairs
Repairs are to be conducted by ecom instruments GmbH or service centres
authorised by ecom instruments GmbH, because the safety of the unit
needs to be tested after repairs are implemented.
The actual repair report sheet can be downloaded from the service area at
www.ecom-ex.com.
10. Cleaning, maintenance and storage
• Only use a suitable cloth or sponge to clean the unit.
• Do not use any solvents or abrasive cleaning agents when cleaning.
• We recommended having the operation and lumen output of the device
checked by the manufacturer every two years.
• The batteries should be taken out of the unit if it is to be stored for
extended periods.
• The storage temperature should be within the permitted range of -30 °C
to +60 °C.
• It should be observed that the electrical performance of specic types
of Zinc-Manganese Dioxide (Zn/MnO2) batteries are limited to ambient
temperatures below the product specied ambient temperature range.
The datasheets for the specic manufacturer and type of battery used
should be consulted to see what the recommended ambient temperature
range of use is to achieve maximum battery performance”
Inhaltsverzeichnis
Sprachen:
Andere Pepperl+Fuchs Taschenlampe Handbücher