Perle IDS-409G Handbuch

IDS-409G Hardware Installation Guide
Managed Industrial Ethernet Switches
Updated: October 2019
Version: A.2.1.10.2019
Document Part#:5500379-10
www.perle.com

IDS-409-SFP Hardware Installation Guide
THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS GUIDE ARE SUBJECT TO CHANGE
WITHOUT NOTICE. ALL STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS GUIDE ARE BELIEVED TO BE
ACCURATE BUT ARE PRESENTED WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. USERS MUST TAKE
FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC
rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in
accordance with this hardware guide may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference, in which case users will be required to correct the interference at their own
expense.
Modifications to this product not authorized by Perle could void the FCC approval and negate your authority to operate the product.
Perle reserves the right to make changes without further notice, to any products to improve reliability, function, or design.
Perle, the Perle logo, and IDS Switch are trademarks of Perle Systems Limited.
©2016 - 2019 Perle Systems Limited.

Table of Contents
Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Switch Models Views . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Port Status Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Terminal Block Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
DIP Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Cautions and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Terminal Block-Power Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Grounding the IDS switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Connecting Power to the IDS Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Wiring the Relay Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Wiring Digital Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Connecting the Console Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Connecting Data Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Resetting the Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Configuring the IDS Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Appendix A - Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Appendix B - Sample Labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Appendix C - Mechanical Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Appendix D - DIN Rail and Wall Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
Appendix E - IDS Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
Appendix F - Cables and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34

2
IDS-409G Hardware Installation Guide
Preface
Audience
This guide is for the network or computer technician responsible for installing Perle IDS
series switches. Familiarity with the concepts and terminology of Ethernet and local area
networks is required.
Purpose
This document describes the hardware and physical characteristics of the Perle IDS
switch. It covers hardware features as well as installation and operation of the switch. This
document does not cover how to configure your Perle IDS switch. Information to config-
ure your Perle IDS switch can be found in the User’s Guide
Package Contents
• IDS switch with attached DIN rail mounting bracket
• Quick Start Guide
Document Conventions
This document contains the following conventions:
Most text is presented in the typeface used in this paragraph. Other typefaces are used to
help you identify certain types of information. The other typefaces are:
Note: Means reader take note: notes contain helpful suggestions.
Caution: Means reader be careful. In this situation, you might perform an action that
could result in equipment damage or loss of data.
Warning: IMPORTANT SAFETY INSTRUCTIONS
Means danger. You are in a situation that could cause bodily injury. Before you work on
any equipment, be aware of the hazards involved with electrical circuitry and be familiar
with standard practices for preventing accidents. Only qualified personnel should connect
power to this unit.

Overview 3
IDS-409G Hardware Installation Guide
Overview
This chapter discusses the following topics:
• LED Indicators
• Switch Model View
• Ports
• Port Status Indicators
The table below gives a brief overview of the models covered in this guide. For more
details and for the most up-to-date list of models, please refer to the product pages at
www.perle.com.
XXXXXXX - represents fiber ports of different wavelengths, distances and connectors
Standard Models 10/100/1000Base-T
Ports
Fiber
Ports Temp
IDS-409G-XXXXXXX 8 1 Standard
IDS-409G2-XXXXXXX 7 2 Standard
IDS-409G3-XXXXXXX 6 3 Standard
IDS-409G-XXXXXXX-XT 8 1 Industrial
IDS-409G2-XXXXXXX-XT 7 2 Industrial
IDS-409G3-XXXXXXX-XT 6 3 Industrial

Overview 4
IDS-409G Hardware Installation Guide
Switch Models Views
IDS-409G-xxxxxxx
IDS-409G-xxxxxxx-XT
1 – Terminal Block for Power 1, 2 8 – Terminal Block – Relay, I/O
2 – Status LEDs 9 – Fiber Status LED
3 – Console Port – serial 10 - 1000Base-X Fiber port
4 – Console Port – USB 11 - Reset / FS (Fast Setup)
5 – DIP switches 12 - Wall Mount Bracket Screw Holes
6 – 10/100/10100 Base-T Ports 13 - DIN Rail Clip
7 – SD Card Slot

Overview 5
IDS-409G Hardware Installation Guide
IDS-409G2-xxxxxxx
IDS-409G2-xxxxxxx-XT
1 – Terminal Block for Power 1, 2 8 - SD Card Slot
2 – Status LEDs 9 – Terminal Block – Relay, I/O
3 – Console Port – serial 10 – 10/100/1000 Base-T Port
4 – Console Port – USB 11 - 1000Base-X Fiber Ports
5 – DIP switches 12 - Reset / FS (Fast Setup)
6 – Fiber Port Status LEDs 13 - Wall Mount Bracket Screw Holes
7 – 10/100/1000 Base-T Ports 14 - DIN Rail Clip

Overview 6
IDS-409G Hardware Installation Guide
IDS-409G3-xxxxxxx
IDS-409G3-xxxxxxx-XT
1 – Terminal Block for Power 1, 2 8 - SD Card Slot
2 – Status LEDs 9 – Terminal Block – Relay, I/O
3 – Console Port – serial 10 - Fiber Port Status LED
4 – Console Port – USB 11 - 1000Base-X Fiber Port
5 – DIP switches 12 - Reset / FS (Fast Setup)
6 – Fiber Port Status LEDs 13 - Wall Mount Bracket Screw Holes
7 – 10/100/1000 Base-T Ports 14 - DIN Rail Clip

Overview 7
IDS-409G Hardware Installation Guide
LED Indicators
P (Power Inputs)
Sys (System Status)
Alr (Alarm)
BC (Backup Coupling)
State Description
Green P1 and P2 Power inputs within specifications
Yellow P1 or P2 Providing power within specifications
Red Neither P1 or P2 providing power within specifications
State Description
Green - blinking (after power on) System booting
Green - solid System ready/operating normally
Green - blinking slowly Fast Setup Mode activated/port available
Green - blinking fast Fast Setup Mode activated/no port avail-
able
Red Hardware fault or firmware load error
State Description
Off No alarms configured
Green - solid Alarms configured, but no alarms detected
Red - solid Alarm condition detected
Red - blinking Alarm condition detected and Alarm Relay activated
State Description
Off Backup Coupling not enabled
Green - solid Backup Coupling Link enabled

Overview 8
IDS-409G Hardware Installation Guide
RM (Ring Master)
State Description
Off Ring Master not activated
Green - solid Ring Master Active, redundant port blocked. Coupling
Link enabled
Green - flashing Ring Master unable to establish a ring due to missing
link on one of the Ring ports
Yellow - solid Ring Master Active, redundant port unblocked - indi-
cates a break in the Ring
Andere Handbücher für IDS-409G
1
Inhaltsverzeichnis
Andere Perle Ethernet-Switch Handbücher
Beliebte Ethernet-Switch Handbücher anderer Marken

Morrell
Morrell SW-UNM-16FE1GC Bedienungsanleitung

LevelOne
LevelOne Infinity IES-1881 Bedienungsanleitung

Digitus
Digitus DN-80100 Bedienungsanleitung

StarTech.com
StarTech.com DS51002 Bedienungsanleitung

ORiNG
ORiNG IES-3162GC Series Bedienungsanleitung

BT
BT 8-Port Gigabit Ethernet Switch Bedienungsanleitung