PI L-220 Bedienungsanleitung

PI miCos GmbH, Freiburger Strasse 30, 79427 Eschbach, Germany
Phone +49 7634 5057-0, Fax +49 7634 5057-99, Email info@pimicos.de, www.pi.ws
MP149E
L
-220 Linear Actuator
User Manual
Version: 1.3
Date: 2020-11-13
This document describes the following high
-
resolution linear actuators:
L-220.10DG
DC drive with gearhead,
travel range 13 mm (0.5")
L-220.10SG
Stepper motor drive with gearhead,
travel range 13 mm (0.5")
L-220.20DG
DC drive with gearhead,
travel range 26 mm (1")
L-220.20SG
Stepper motor drive with gearhead,
travel range 26 mm (1")
L-220.50DG
DC drive with gearhead,
travel range 52 mm (2")
L-220.50SG
Stepper motor drive with gearhead,
travel range 52 mm (2")
L-220.70DG
DC drive with gearhead,
travel range 77mm (3")
L-220.70SG
Stepper motor drive with gearhead,
travel range 77mm (3")

The following company names and brands are registered trademarks of
Physik Instrumente (PI) GmbH & Co. KG:
PI®, NanoCube®, PICMA®, PIFOC®, PILine®, NEXLINE®, PiezoWalk®, PicoCube®, PiezoMove®, PIMikroMove®,
NEXACT®, Picoactuator®, PInano®, NEXSHIFT®, PITOUCH®, PIMag®, PIHera, Q-Motion®
© 2020 Physik Instrumente (PI) GmbH & Co. KG, Karlsruhe, Germany. The text, photographs, and drawings in
this manual are protected by copyright. With regard thereto, Physik Instrumente (PI) GmbH & Co. KG reserves
all rights. The use of any text, images and drawings is permitted only in part and only when indicating the
source.
Original instructions
First printing: 13.11.2020
Document number: MP149E, MMa, Version 1.3
Subject to change without notice. This manual is superseded by any new release. The latest release is
available for download from our website.

1About this Document 1
1.1 Objective and Target Group of this User Manual ...................................................... 1
1.2 Symbols and Typographic Conventions...................................................................... 1
1.3 Definition of Terms..................................................................................................... 2
1.4 Further Applicable Documents................................................................................... 2
2Safety 3
2.1 Intended Use .............................................................................................................. 3
2.2 General Safety Instructions ........................................................................................ 3
2.2.1 Organizational Measures............................................................................... 4
3Product Description 5
3.1 Model Overview ......................................................................................................... 5
3.2 Product View .............................................................................................................. 6
3.3 Direction of motion .................................................................................................... 7
3.4 Product Labeling......................................................................................................... 7
3.5 Scope of Delivery........................................................................................................ 8
3.6 Suitable Controllers .................................................................................................... 8
3.7 Technical Features...................................................................................................... 9
3.7.1 Rotary Encoder .............................................................................................. 9
3.7.2 Limit Switches................................................................................................ 9
3.7.3 Reference Point Switch.................................................................................. 9
4Unpacking 11
5Installation 13
5.1 General Notes on Installation................................................................................... 13
5.2 Providing a Suitable Mechanical Mounting and Installation Environment.............. 13
5.3 Installing the Linear Actuator in a Mechanical Mounting ........................................ 15
5.4 Mounting a Tip ......................................................................................................... 16
5.5 Changing the Tip....................................................................................................... 18
6Start-Up 19
6.1 General Notes on Start-Up....................................................................................... 19
6.2 Starting up the Linear Actuator................................................................................ 21
6.2.1 L-220 Entries in the Stage Database of PI.................................................... 21
Contents

7Maintenance 23
7.1 Performing a Maintenance Run ............................................................................... 23
7.2 Cleaning the L-220.................................................................................................... 24
8Troubleshooting 25
9Customer Service 27
10 Technical Data 29
10.1 Specifications............................................................................................................ 29
10.1.1 Data Table.................................................................................................... 29
10.1.2 Maximum Ratings........................................................................................ 30
10.1.3 Ambient Conditions and Classifications ...................................................... 31
10.1.4 Limit Switch Specifications .......................................................................... 31
10.1.5 Reference Point Switch Specifications ........................................................ 31
10.2 Dimensions ............................................................................................................... 32
10.2.1 Linear Stage ................................................................................................. 32
10.2.2 Tips............................................................................................................... 33
10.3 Pin Assignment ......................................................................................................... 34
10.3.1 HD Sub-D 26 (m) .......................................................................................... 34
10.4 Tightening Torque for Screws, ISO 4762 - A2........................................................... 36
11 Old Equipment Disposal 37
12 EU Declaration of Conformity 39

1 About this Document
L-220 Linear Actuator MP149E Version: 1.3 1
1.1 Objective and Target Group of this User Manual
This user manual contains the necessary information on the intended use of the L-220.
Basic knowledge of closed-loop systems, motion control concepts, and applicable safety
measures is assumed.
The latest versions of the user manuals are available for download on our website (p. 2).
1.2 Symbols and Typographic Conventions
The following symbols and typographic conventions are used in this user manual:
CAUTION
Dangerous situation
If not avoided, the dangerous situation will result in minor injury.
Actions to take to avoid the risk.
NOTICE
Dangerous situation
If not avoided, the dangerous situation will result in damage to equipment.
Actions to take to avoid the risk.
INFORMATION
Information for easier handling, tricks, tips, etc.
Symbol/
Label
Meaning
1.
2.
Action consisting of several steps whose sequential order must be
observed
Action consisting of one or several steps whose sequential order is
irrelevant
Lists
p. 5 Cross-reference to page 5
1
About this Document

1 About this Document
2 Version: 1.3 MP149E L-220 Linear Actuator
1.3 Definition of Terms
Term Explanation
Load capacity Maximum load capacity in the vertical direction when the linear
actuator is mounted horizontally. The contact point of the load is at
the center of the motion platform.
Max. push/pull force Maximum force in the direction of motion. Some stages may have
higher forces but with limited lifetimes. In the case of vertical
mounting, the specified value (s. 29) for models without a gearhead
and brake only applies when the servo mode is on.
Rotary encoder The rotary encoder is a sensor for capturing changes in position.
Signals from the sensor are used for axis position feedback. After the
controller is switched on, a reference point definition must be
performed before absolute target positions can be commanded and
reached.
1.4 Further Applicable Documents
The devices and software tools from PI that are mentioned in this documentation are described
in separate manuals.
Product Document
L-220 MP159EK Short instructions for
L-2xx/MA-35/MP-20/MP-15 linear actuators
C-863.12 * MS249E User manual
C-663.12* MS241E User manual
C-884* MS243E User manual
C-885** C885T0002 User manual
C-663.12C885* C663T0004 User manual
C-863.20C885* C863T0005 User manual
C-885* C885T0002 User manual
C-663.12C885* C663T0004 User manual
SMC Hydra Technisches Benutzerhandbuch SMC Hydra
(SMC-Hydra CM TT.doc)
* Depending on the ordered controller. Further documents included in the data carrier(s)
provided with the controller.

2 Safety
L-220 Linear Actuator MP149E Version: 1.3 3
2.1 Intended Use
The L-220 is a laboratory device as defined by DIN EN 61010-1. It is intended for indoor use and
use in an environment which is free of dirt, oil, and lubricants.
In accordance with its design, the L-220 is intended for single-axis positioning, adjusting and
shifting of loads at various velocities.
The intended use of the L-220 is only possible when installed and in conjunction with a suitable
controller. The controller is not included in the scope of delivery of the L-220.
2.2 General Safety Instructions
The L-220 is built according to state-of-the-art technology and recognized safety standards.
Improper use of the L-220 may result in personal injury and/or damage to the L-220.
Only use the L-220 for its intended purpose, and only use it if it is in good working
order.
Read the user manual.
Immediately eliminate any faults and malfunctions that are likely to affect safety.
The operator is responsible for the correct installation and operation of the L-220.
2
Safety

2 Safety
4 Version: 1.3 MP149E L-220 Linear Actuator
2.2.1 Organizational Measures
User manual
Always keep this user manual available when using the L-220.
The latest versions of the user manuals are available on our website (p. 2) for
download.
Add all information from the manufacturer such as supplements or technical notes to
the user manual.
If you give the L-220 to other users, also include this user manual as well as all other
relevant information provided by the manufacturer.
Only use the device on the basis of the complete user manual. Missing information due
to an incomplete user manual can result in minor injury and damage to equipment.
Only install and operate the L-220 after you have read and understood this user
manual.
Personnel qualification
The L-220 may only be installed, started up, operated, maintained, and cleaned by authorized
and appropriately qualified personnel.

3 Product Description
L-220 Linear Actuator MP149E Version: 1.3 5
3.1 Model Overview
There are six standard versions of the L-220. All models are high-resolution linear actuators with
a limit switch. They differ with respect to:
Drive type
Travel range
Model Travel range Drive type
13 mm 26 mm 52 mm 77 mm DC gear
motor
Step
gear motor
L-220.10DG + +
L-220.10SG + +
L-220.20DG + +
L-220.20SG + +
L-220.50DG + +
L-220.50SG + +
L-220.70DG + +
L-220.70SG + +
Detailed model overview
Order number Product name
L-220.10DG High-resolution linear actuator, DC gear motor, 13 mm (0.5") travel
range, magnetic limit switches
L-220.10SG High-resolution linear actuator, stepper motor with gearhead, 13 mm
(0.5") travel range, magnetic limit switches
L-220.20DG High-resolution linear actuator, DC gear motor, 26 mm (1") travel range,
magnetic limit switches
L-220.20SG High-
resolution linear actuator, stepper motor with gearhead, 26 mm (1")
travel range, magnetic limit switches
L-220.50DG High-resolution linear actuator, DC gear motor, 52 mm (2") travel range,
magnetic limit switches
L-220.50SG High-
resolution linear actuator, stepper motor with gearhead, 52 mm (2")
travel range, magnetic limit switches
3
Product Description

3 Product Description
6 Version: 1.3 MP149E L-220 Linear Actuator
L-220.70DG High-resolution linear actuator, DC gear motor, 77 mm (3") travel range,
magnetic limit switches
L-220.70SG High-
resolution linear actuator, stepper motor with gearhead, 77 mm (3")
travel range, magnetic limit switches
For further technical data, see the specifications (p. 29).
PI also produces custom versions upon request. Custom versions can differ from the described
standard products in respect to dimensions, characteristics or other technical data.
If necessary, contact our customer service department directly (p. 27).
3.2 Product View
Figure 1: Parts of the L-220 (here with flat tip)
1
Tip, replaceable (here: Flat, mounted on pusher)
2Thread for clamp connection
3Mounting nut for clamp connection
4Smooth cylinder surface, e.g., for mounting in a hole
5Sleeve
6Cable
7Controller connection (HD Sub-D 26, male)
Dieses Handbuch passt für folgende Modelle
8
Inhaltsverzeichnis
Andere PI Controller Handbücher

PI
PI PIMag V-27 Series Handbuch

PI
PI M-238 Bedienungsanleitung

PI
PI A-811.21 Series Bedienungsanleitung

PI
PI PICMA P-840 Handbuch

PI
PI M-232.17 Bedienungsanleitung

PI
PI N470 Series Bedienungsanleitung

PI
PI V-273 VC Bedienungsanleitung

PI
PI P-843 Bedienungsanleitung

PI
PI P-844 Bedienungsanleitung

PI
PI A-812.21 Series Bedienungsanleitung

PI
PI E-871.1A1N Bedienungsanleitung

PI
PI PZ265E Bedienungsanleitung

PI
PI MP106E Bedienungsanleitung

PI
PI N-472 Bedienungsanleitung

PI
PI PiezoMove P-601 Handbuch

PI
PI M-235.2DG Handbuch

PI
PI E-651.1S Bedienungsanleitung

PI
PI C-863 Handbuch

PI
PI M-227 Series Bedienungsanleitung

PI
PI P-840.XXV Series Bedienungsanleitung