Product Specications
Model 57001A
Current 220-240V
Power 60W
Maximum operating pressure <0.2bar (3psi)
Ecient ltration surface 0.058m²(0.62ft²)
Maximum water ow 3,03m3/h (800 gallons/h)
Maximum water temperature 35°C
Type of ltering media Sand, zeolite, recycled glass lter, foam
lter (special swimming pool)
Recommended sand quantity 10 kg

3
Safety notice
Please follow the safety instructions concerning the installation and use of this
electrical equipment:
This equipment must not be manipulated by children less than 8 years old and
persons with reduced sensory or mental abilities, or lacking experience and
knowledge, if they are not properly supervised and if instructions related to the
safe use of the equipment have not been provided and if risks incurred were
not ascertained. Children must not play with the equipment. Cleaning and
maintenance of the equipment is not to be done by children without supervi-
sion.
The pump must not be installed in swimming pools. It must be installed and
used according to installation regulations NFC 15-100.
Please ensure the ltration pump is situated at least 2 meters away from the
side of the swimming pool.
The pump electric plug must be situated at least 3.5 meters from the swimmi-
ng pool.
Please consult with your specialized electrician.
Warning: risk of electrical shock. This product is protected with an earth
safety. If you are unable to check whether your installation is equipped with
earth safety or a circuit breaker, please contact an experienced technician
prior to installation. Maximum leakage value must not exceed 30mA.
Warning: please disconnect the power supply to the equipment before mo-
ving, cleaning or adjusting the product.
Warning: do not bury the cable underground and install it in a secure place
where lawn mower and other equipment cannot damage it.
The power cable must not be replaced. If it has been damaged, do not use the
equipment.
Warning: to reduce any risk of electric shock, do not connect to an extension
cable, a timer or a converter. Only use the electric plug provided.
Warning: do not connect or disconnect the electric plug if you are in a wet
environment or if your hands are wet.
Warning: after installation, the electric plug must be positionned in a way to
be visible and accessible by users.

4
Warning: do not use this product when the swimming pool is in use.
Warning: installing and dissassembly must be done by adults only.
Warning: this product must not be used for above-ground swimming pools. It
cannot, in any way, be used for sheltered pools.
Warning: to avoid any type of damage, only use the 6-way valve when the
product is disconnected from electricity.
Warning: to avoid any electrical risk, do not use this product if the cover has
not been properly xed or if it is damaged. If the cover is damadged, it must be
changed before any further use.
Warning: do not play or swim near the suction plug or outlet. Your body or
your hair can be sucked and cause damage.
Warning: when value on pressure gauge exceeds predened maximum va-
lue, do not start the product.
Warning: pressure that is too high or incorrectly installed cover can cause an
explosion with body damage.
Caution: The product must be used only within the limits dened in this
manual.

5
What you will nd in your package
Clamp ring Cover with 6-way valve Filtration shell
Corrugated pipes
Strainer
Cover joint
Filtration return hose
Hose clamp 32/50 Connectors 32/38
Suction and discharge prelters
Hose clamp 25/42
Central tube
Central tube plug
26
26
28

6

7
Parts reference table
N° Name Quantity N° Name Quantity
1Cover with 6-way
valve
1 16 Prelter sealing joint 1
2Sealing joint 3 17 Prelter plug 1
3 Sealing plug 1 18 32/38 connectors 1
4 Pressure gauge 1 19 38 sealing joint 3
5 Pressure gauge seal-
ling joint
1 20 32 sealing joint 2
6M8 screw 1 21 32-50 hose clamp 2
7Washer 1 22 Φ38 corrugated pipe 1
8Central tube protec-
tion cap
123 Upper cover sealing joint 1
9Central connection
tube
6 24 Clamp ring 1
10 Strainer 1 25 M8 nut 1
11 Safety pin 1 26 Suction prelter 2
12 Drain plug 1 27 25-42 hose clamp 4
13 Drain plug joint 1 28 Φ32 connection pipe to
the swimming pool
2
14 Electric pump + ltra-
tion shell group
1
15 Pump prelter 1

8
Installation instructions:
Carefully prepare the area where your ltration group will be installed.
Important advice:
This product must be installed on a stable, rigid, levelled surface with enoug space
provided above it for its handling and maintenance. Please ensure to follow all current
regulations in your region relative to the installation of a ltration group.
The ltration group must be secured to the ground with three xation points, ideally on
a concrete slab or a wood oor (screws not provided).
Caution: xation diameter at the base is 8 mm
Caution: maximum diameter for two screws and xing nut is 8mm.

9
Filling up with lter media:
Caution: use ltration sand specic for swimming pools. Sand granulometry must be
between 0.45 and 0.85mm. (or between 0.018-0.033 inch), general grain homoge-
neous coecient is lower than 1.75.
It is also possible to use foam type media such as «Pureow» instead of lter sand.
Step 1
Assembly of the elements of the ltration
unit.
Before loading sand or lter foam, insert the
central tube (3) into the strainer (10) until
the tube is completely clipped. Be careful
not to break the strainer clips when inserting
the tube. The safety pin must t perfectly
between the clips of the strainer.
Then turn over the strainer + central tube
assembly and install it in the ltration unit.
Step 2
Position the cap on the central tube (8) to
avoid any presence of sand in the tube.
Gradually pour 10 kg of sand to avoid spilling
it into the upper groove of the tank.
Once the sand has been poured, spread it
evenly by hand.
Step 3
Remove the cap from the central lter tube
(8).
3
10
8

10
Step 1
Clean the top groove of any sand that may be
inside before installing the gasket.
Step 2
The cover (A) and the lter body (B) are
equipped with a notch (C, D) to indicate the
mounting orientation of the cover. Make sure
these notches line up perfectly with each
other.
Step 3
Install the clamp ring so that it encircles the
ange of the cover and of the lter shell.
Secure using the screw (6) and the washer
(7) on one side, and the m8 nut (25) on the
other, and tighten it using a suitable screw-
driver.
Installing the control cover
Warning :
The presence of sand or any other foreign body in the groove or on the seal can cause
a leak or even an explosion of the ltration unit.
23
24
6725
Inhaltsverzeichnis
Beliebte Beleuchtungsausrüstung Handbücher anderer Marken

Qazqa
Qazqa Suplux SL 3 Black 103062 Bedienungsanleitung

Commercial Electric
Commercial Electric 54568141 Bedienungsanleitung

CREE LIGHTING
CREE LIGHTING 304 Series Bedienungsanleitung

Goobay
Goobay 49867 Bedienungsanleitung

ECOMAN ITALIA
ECOMAN ITALIA LED T8 Bedienungsanleitung

Alkalite
Alkalite Krypton KT-81 Bedienungsanleitung