Powerfix KH 3236 Bedienungsanleitung

KOMPERNASS GMBH · BURGSTRASSE 21 ·
D-44867 BOCHUM
www.kompernass.com
ID-Nr.: KH3236-01/08-V1
4B
CV_KH3236_BN3376_LB4B 05.03.2008 14:04 Uhr Seite 1

MULTI-DETECTOR
Bedienungsanleitung
MULTIFUNKČNÍ DETEKTOR
Návod k obsluze
MULTIDETEKTOR
Návod na obsluhu
MULTI-DETECTOR
KH 3236
CV_KH3236_BN3376_LB4B 05.03.2008 14:04 Uhr Seite 2

CV_KH3236_BN3376_LB4B 05.03.2008 14:04 Uhr Seite 3

1
3
2
5
6
7
8
9
0
4
KH 3236
q
w
e
r
t
z
CV_KH3236_BN3376_LB4B 05.03.2008 14:04 Uhr Seite 4

- 1 -
CONTENT PAGE
Intended use 2
Safety instructions 2
Technical data 3
Description of the appliance 4
Items supplied 4
Unpacking 4
Inserting the battery 4
Measuring distances 5
Measuring areas 6
Measuring volumes 7
Locating concealed objects 8
Laser marking 10
Battery display 11
Cleaning and storage 11
Disposal 11
Service 12
Importer 12
Read the operating instructions carefully before using the appliance for the first time
and preserve this booklet for later reference. Pass the manual on to whomsoever might
acquire the scale at a later date.
IB_KH3236_BN3376_GB_LB4u5 29.02.2008 18:06 Uhr Seite 1

- 2 -
MULTI-DETECTOR KH 3236
Intended use
The Multi-Measurement Detector is designed for the locating of electrical cables,
of wood and metal objects, for the projecting of laser lines, for the measuring of
areas and volumes as well as for the measuring of distances. The appliance is
intended for domestic use only. Do not use it for commercial purposes.
Safety instructions
Risk of injury!
• Do not use the appliance at locations where there is a risk of fire or
explosion, e. g. close to inflammable liquids or gases.
• This appliance is not intended for use by individuals (including children)
with restricted physical, physiological or intellectual abilities or deficiences
in experience and/or knowledge unless they are supervised by a person
responsible for their safety or receive from this person instruction in how
the appliance is to be used.
• Children should be supervised to ensure that they do not play with the
appliance.
• Exercise caution with the holding pins. They are sharp and can cause
injuries.
Caution regarding damage to the appliance!
• Do not expose the appliance to rainfall. Do not use the appliance in moist
or wet environments.
• Do not place objects containing liquids, e. g. flower vases, on the appliance.
• Do not place any open sources of fire, like candles, on the device.
This appliance contains a Class 2 laser. NEVER direct the laser
beam at people or animals. NEVER look directly into the laser.
The laser can cause serious eye damage.
• Do NOT direct the laser beam at strongly reflective material.
Reflected laser beams are also dangerous.
• Do NOT use the appliance to determine the alternating voltage level in
exposed or non-insulated power cables.
• Do NOT use the appliance as a substitute for a voltmeter.
IB_KH3236_BN3376_GB_LB4u5 29.02.2008 18:06 Uhr Seite 2

- 3 -
The appliance does not always recognise all pipes and power cables.
The following conditions can contribute to inaccurate results:
– very thick walls
– weak battery
– deeply laid power cables or pipework
– shielded cables
– thick walls with thin pipes or power cables
– walls panelled with metal sheets
– very moist conditions
• This appliance is not suitable for detecting power cables in circuits,
– which are isolated from the mains power supply.
– through which direct current flows.
– which are used for computer or telecommunications systems.
• With this appliance pipework made of plastic or similar materials
cannot be detected, only pipework made of metal.
• No warranty will be accepted for damage caused by manipulation
of the laser equipment, as well as of the ultrasound transmitter/receiver,
and through disregard of the safety instructions.
Interaction with batteries:
• Leaking batteries can cause damage to the appliance. If you do not intend
to use the appliance for an extended period, remove the batteries.
• Should the batteries leak, wear protective gloves and clean the battery
compartment with a dry cloth.
• Keep batteries away from children. Children can put batteries into their
mouths and swallow them. Should a battery ever be swallowed, seek
medical attention IMMEDIATELY.
Technical data
Distance measurement by means of Ultrasound
Locating of: power cables, metal, wood
Laser class: II (650 nm)
Pmax: < 1 mW
Power supply: 9 V block battery
IB_KH3236_BN3376_GB_LB4u5 29.02.2008 18:06 Uhr Seite 3

- 4 -
Description of the appliance
1Measurement point
2Display
3Material switch (STUD/AC WIRE/METAL)
4Button – MODE
5Button – Holding pin
6Button – READ
7Button M (Memory)
8Spirit level
9Laser
0Ultrasound sender/receiver
qFunction switch (Laser/Detector/Distance)
wButton – RM (Read Memory)
eButton – Holding pin
rButton +/=
tBattery compartment
zButton – PUSH
Items supplied
• 5 in 1 Multi-Measurement Detector with Laser
• 9 V block battery
• Operating instructions
Unpacking
Take the Manifold Measurer from its packaging. Remove all transport restraints
and packaging materials. Remove the protective foil from the display 2.
Inserting the battery
1. Open the battery compartment ton the rear side of the Multi-Measurement
Detector.
2. Place the 9 V block battery onto the contacts. Pay heed to the correct polarity.
3. Lay the tape for removal of the battery underneath the 9 V block battery and
press it into the battery compartment t.
Important!
Ensure that the wires are not trapped in any way.
This would lead to irreparable damage to the appliance.
IB_KH3236_BN3376_GB_LB4u5 29.02.2008 18:06 Uhr Seite 4

- 5 -
4. Close the battery compartment t. The battery compartment lid must close
with an audible click.
Measuring distances
1. Slide the function switch qto „Distance“. The display 2switches itself on.
To switch between the metric and the Anglo-American units of measurement,
press and hold the button MODE 4. Then press the button READ 6and release
both buttons simultaneously. When you release the buttons, the measurement
units change.
Note:
Measurements start at the measurement point 1!
Should the measurement lie outside the measurement range, „Err“ or an illogical
number appear in the display. The measurement range lies between 0,6 m (2“)
and 16 m (53“).
2. Hold the appliance upright towards the wall to which you wish to measure
the distance. The ultrasound sender/receiver 0must be at a right-angle to
the wall. For this, use the spirit level: The bubble in the glass 8must stand
between the marking lines (see Fig. 1).
3. Press the button READ 6. The distance measured appears in the display 2.
When you hold the button READ 6pressed down and slowly move the
appliance over the surface to be measured, the appliance continually
measures the distances. These are shown on the display 2.
Take note of the following illustrations:
Fig. 1 Fig. 2
The further you are from the wall, the wider is the area (a) that the Multi-
Measurement Detector must measure by ultrasound (Fig. 2). Therefore take care
that the Manifold Measurer is always directed at a right angle towards a level
surface (Fig. 1 and 3). Ensure that there are no objects positioned within the
measurement area.
IB_KH3236_BN3376_GB_LB4u5 29.02.2008 18:06 Uhr Seite 5

- 6 -
False!
(Fig. 3)
The display illumination glows during the measurement. If a button is not pressed
within ca. 15 seconds, the illumination extinguishes. After a further ca. 15 seconds
the diplay itself switches off. Press the button READ 6, to reactivate the display
and the illumination.
Note:
Inaccurate measurements can also occur through a weak battery.
If the battery is too weak, the battery symbol appears in the display.
Adding distances together
You can add the measured distances together:
1. Measure the first distance as described.
2. Press the button +/= r. In the display 2, „+“ appears and the distance
measured carries itself over to the lower line.
3. Measure the next distance. The newly measured distance is shown in the
upper line.
4. Once again, press the button +/= r. The new measurement is added
to the old measurement in the lower line.
5. Repeat steps 2 to 4 to add further measurements.
6. When you wish to leave the addition mode, press the button MODE 4.
All values are erased.
Measuring areas
1. Slide the function switch qto „Distance“.
The display 2switches itself on.
2. Press the button MODE 4once. In the display 2flashes „L“ (Length).
IB_KH3236_BN3376_GB_LB4u5 29.02.2008 18:06 Uhr Seite 6
Inhaltsverzeichnis
Sprachen:
Andere Powerfix Sicherheitssensor Handbücher