Promatic CMP25-2 Bedienungsanleitung

PROMATIC CMP25-2
Régulateur de vanne mélangeuse pour circuits de chauffage
FRE
Witterungsgeführte Heizungsregler des Mischerheizkreises
DEU
Weather compensated controller for mixing heating circuits
ENG
Regolatore climatico per circuiti di riscaldamento miscelati
ITA


ENGDEUDUTFRE
Weather compensated controller for mixing heating circuits
PROMATIC CMP25-2
Witterungsgeführte Heizungsregler des Mischerheizkreises
PROMATIC CMP25-2
Weersafhankelijke regelaar voor mengverwarmingscircuits
PROMATIC CMP25-2
Régulateur de vanne mélangeuse pour circuits de chauffage
PROMATIC CMP25-2


ENG
5
INTRODUCTION
PROMATIC CMP25-2 controller is a modern designed, microprocessor-driven device
made with digital and SMT technology.
It is intended to control mixing heating circuit with radiator or surface heating systems.
CMP25-2 features multi-chanel program timer for time-dependent room heating.
CMP25-2 controllers can be connected to network and operate as uniform control system
for multi heating circuits.
For initial setup see Initial controller setup, page 9!
Weather compensated controller for mixing heating circuits
PROMATIC CMP25-2

ENG
6
CONTENTS
USER MANUAL
CONTROLLER DESCRIPTION..................................................................................8
Controller appearance.................................................................................................8
Operation mode indication ..........................................................................................8
INITIAL SETUP OF CONTROLLER...........................................................................9
Procedure of initial setup.............................................................................................9
MAIN DISPLAY AND NAVIGATION ........................................................................11
Main display description and design..........................................................................11
Description of symbols shown on display..................................................................11
Symbols for operation mode..............................................................................11
Symbols for user functions ................................................................................12
Symbols for temperature ans data overview .....................................................12
Symbols for protection functions .......................................................................13
Symbols for communication of controllers in network........................................13
Symbols for notice and warnings.......................................................................13
Basic screen navigation ............................................................................................14
Locking / unlocking the screen ..................................................................................14
Display for help, notices and warnings......................................................................15
ENTRY AND NAVIGATION THROUGH THE MENU ...............................................16
Menu structure and description .................................................................................17
Temperture settings ...........................................................................................20
User functions ...................................................................................................21
Operation mode .................................................................................................22
Time programs ...................................................................................................23
Basic settings ............................................................................................................26
Data Overview...........................................................................................................27
SERVICE SETTINGS MANUAL
SERVICE SETTINGS................................................................................................28
Basic parameters ......................................................................................................28
Heat curve..........................................................................................................30
Service parameters ...................................................................................................32
Floor drying parameters ............................................................................................35
Factory settings.........................................................................................................36

ENG
7
INSTALLATION MANUAL
CONTROLLER INSTALLATION ..............................................................................37
Installation onto mixing valve ....................................................................................37
Controller's electric connection..................................................................................39
Connection of mains...........................................................................................39
Connection of sensors, room units and BUS......................................................39
Connection of digital room unit DD2+.................................................................40
Connection of room sensor ................................................................................40
Marking and installation of temperature sensors ................................................41
Operation mode by sensor failure ......................................................................42
Expanding the system on multiple heating circuits.............................................42
HYDRAULIC AND ELECTRIC SCHEMES...............................................................44
TECHNICAL DATA...................................................................................................47
DECLARATIONS AND STATEMENTS....................................................................48
Conformity with standards and directives..................................................................48
Disposal of old electrical & electric equipment ..........................................................48

ENG
8User manual
USER AND SETTINGS MANUAL
CONTROLLER DESCRIPTION
OPERATION MODE INDICATION
CONTROLLER APPEARANCE
1 2
Graphic display with touch panel.
Button - Esc, Help.
Illuminated button:
green - closing of mixing valve
red - opening of mixing valve
2
1

ENG
9 User manual
INITIAL SETUP OF CONTROLLER
Controller PROMATIC CMP25-2 is equipped with innovative solution “EASY START” for
easy setup with the help of setup wizard.
When you connect the controller to the power supply
for the first time or by reset, the software version is
shown. Next, the setup wizard runs.
PROCEDURE OF INITAL SETUP
On screen appears picture for selecting the display orientation.
Press icon where letter Ais normally readable.
After selecting proper display orientation, press button to confirm your selection.
STEP 1 - DISPLAY ORIENTATION
Press icon which indicates the proper direction ( ) of mixing valve opening.
After selecting proper valve opening direction, press button to confirm your selection.
STEP 2 - OPENING OF THE MIXING VALVE
OR

ENG
10User manual
RESET
Switch off power supply of the controller. Hold button and switch on
power supply. Controller resets and runs initial setup.
Press icon which indicates your language.
After selecting proper language, press button to confirm your selection.
STEP 3 - LANGUAGE SELECTION
Select scheme for controller operation.
Confirm your selection with button .
STEP 4 - HYDRAULIC SCHEME
Selected hydraulic scheme, screen orientation direction, rotation direction
and language can be at any time changed in service settings or with reset of
controller!
Press buttons and to set requested heat curve
steepness. Confirm your selection with button .
Heat curve steepness is detailed described on pages 30
and 31.
STEP 5 - HEAT CURVE STEEPNESS
OR
Inhaltsverzeichnis
Sprachen:
Andere Promatic Controller Handbücher