ProSoft Technology PLX51-DLplus-232 Bedienungsanleitung

PLX51-DLplus-232
Data Logger Plus
Data Storage Module
October 3, 2019
USER MANUAL

Page 2

Page 3
CONTENTS
1Preface .................................................................................................................................... 7
1.1 Introduction to the PLX51-DLplus-232............................................................................. 7
1.2 Features............................................................................................................................ 8
1.3 Additional Information................................................................................................... 10
2Installation ............................................................................................................................ 11
2.1 Module Layout ............................................................................................................... 11
2.2 Module Mounting .......................................................................................................... 13
2.3 Power ............................................................................................................................. 14
2.4 RS232 Port...................................................................................................................... 14
2.5 Ethernet Port.................................................................................................................. 14
3Setup ..................................................................................................................................... 15
3.1 Install Configuration Software ....................................................................................... 15
3.2 Network Parameters...................................................................................................... 15
DHCP Server Settings ............................................................................................................ 15
Network Settings................................................................................................................... 18
3.3 Creating a New Project................................................................................................... 20
3.4 Configuring the PLX51-DLplus-232................................................................................. 22
General Tab........................................................................................................................... 22
Serial Tab............................................................................................................................... 24
3.5 Data Source Configuration............................................................................................. 25
Group and Tag Triggers......................................................................................................... 26
Logix Source .......................................................................................................................... 26
DF1 Source ............................................................................................................................ 29
Modbus Source..................................................................................................................... 30
3.6 Module Download.......................................................................................................... 31
4RSLogix 5000 Configuration.................................................................................................. 33
4.1 Add Module to I/O Configuration .................................................................................. 33
4.2 Importing UDT’s and Mapping Routines........................................................................ 35

Page 4
4.3 RSLogix 5000 assemblies................................................................................................ 38
Input Assembly...................................................................................................................... 38
4.4 Inhibiting the Module..................................................................................................... 39
5Diagnostics............................................................................................................................ 41
5.1 LEDs ................................................................................................................................ 41
5.2 Module Status Monitoring............................................................................................. 42
General Tab........................................................................................................................... 44
Statistics tab.......................................................................................................................... 45
Tag Status Tab....................................................................................................................... 46
Recent Records Tab .............................................................................................................. 47
Record Management Tab ..................................................................................................... 48
CIP Statistics Tab ................................................................................................................... 49
Ethernet Clients Tab.............................................................................................................. 50
TCP / ARP Tab........................................................................................................................ 51
6Retrieving Logged Data from the PLX51-DLplus-232............................................................ 53
6.1 DF1 Packet Capture........................................................................................................ 53
6.2 Modbus Packet Capture................................................................................................. 56
6.3 Module Event Log........................................................................................................... 59
6.4 Web Server..................................................................................................................... 61
6.5 Web Reporting ............................................................................................................... 62
Retrieve Trend Data.............................................................................................................. 64
Customize Graph Axis ........................................................................................................... 67
Upload Records to CSV File................................................................................................... 71
7JSON Client............................................................................................................................ 73
7.1 General Status................................................................................................................ 73
7.2 Cache Statistics............................................................................................................... 74
7.3 Unload Log Index Update............................................................................................... 74
7.4 Cache Records................................................................................................................ 75
7.5 Reset Log Indexes........................................................................................................... 76
7.6 Get Tag Names ............................................................................................................... 76
7.7 Trend Data...................................................................................................................... 77

Page 5
7.8 Trend Data UTC .............................................................................................................. 78
7.9 Invalid Request Response .............................................................................................. 80
7.10 Operation ....................................................................................................................... 80
Get Tag Database.................................................................................................................. 80
Get Trend Data...................................................................................................................... 80
Get Cache Records................................................................................................................ 81
7.11 Examples ........................................................................................................................ 82
General Status Message ....................................................................................................... 82
Cache Records Message........................................................................................................ 83
8Technical Specifications........................................................................................................ 85
8.1 Dimensions..................................................................................................................... 85
8.2 Electrical......................................................................................................................... 86
8.3 Ethernet.......................................................................................................................... 86
8.4 Data Cache ..................................................................................................................... 87
8.5 Serial Port....................................................................................................................... 87
8.6 DF1.................................................................................................................................. 87
8.7 Modbus .......................................................................................................................... 88
8.8 Agency Approvals & Certifications................................................................................. 88
9Support, Service & Warranty................................................................................................ 89
9.1 Contacting Technical Support ........................................................................................ 89
9.2 Warranty Information .................................................................................................... 91
10 Index...................................................................................................................................... 93

Page 6

Page 7
1PREFACE
1.1 Introduction to the PLX51-DLplus-232
This manual describes the installation, configuration, operation, and diagnostics of the PLX51-
DLplus-232. The PLX51-DLplus-232 can read and store data from Logix Controllers, DF1 Serial
Interfaces, or Modbus devices. The PLX51-DLplus-232 has the capacity to store over 16 million
records in its solid-state non-volatile memory. Each stored record includes a Date Time stamp
with a 50 ms resolution, Tag Name, Data Type, and Value.
The PLX51-DLplus-232 can be used to log data at a remote site with limited communication
with its base. The PLX51-DLplus-232 is also used to store records on mobile equipment such as
trucks, drilling rigs, or snow plows. Once the equipment returns back to its base, the historical
data can be uploaded and transferred to a more permanent storage device. The PLX51-DLplus-
232 can also be configured to collect data which is only downloaded and examined if a fault
occurs, otherwise the data is overwritten.
Compared to the PLX51-DL-232, the PLX51-DLplus-232 has the following additional features:
Trend up to five variables dynamically via the integrated webserver
Upload logged data directly from the integrated webserver
REST API support retrieves data automatically via JSON-encoded messages.

Page 8
Non-Historian Option
1.2 Features
The PLX51-DLplus-232 provides temporary extensive on-board storage capability for storing
process tags. A total of 16,777,216 records can be stored in its non-volatile memory.
Each record consists of the following data:
Parameter
Link
Date Time
UTC Time includes: Year, Month, Day, Hour, Minute, Second, Milliseconds.
Time has a resolution of 50 milliseconds.
Tag Name
As defined in Controller or in the PLX50 Configuration Utility for other sources
Data Type
BOOL, SINT, INT, DINT, or REAL
Value
Logix Tag / DF1 File / Modbus Register value
Components of a Record

Page 9
The Log Index is managed by the PLX51-DLplus-232 and incremented each time a new record is
stored. The Unload Index is managed externally by the unload service. It is only incremented after
a record has been logged successfully to a text file. The records can be unloaded in Logix with the
Example Code. Both the Log Index and Unload Indices loop around, eventually reaching the end
of the cache. The cache becomes 100% full when the Log Index loops around and equals the
Unload Index. In this situation, either older records are overwritten (Log Mode = Overwrite) or
newer records are not logged (Log Mode = Hold).
Memory Schematic
The PLX51-DLplus-232 is configured using the ProSoft PLX50 Configuration Utility. This program
can be downloaded from www.prosoft-technology.com, free of charge. The PLX50 Configuration
Utility offers various configuration methods, including a controller tag browser. The PLX50
Configuration Utility can also be used to monitor the status and download historical data to a
local file.
The PLX51-DLplus-232 can operate in both a Logix “owned” and standalone mode. With a Logix
connection, the input and output assemblies provide additional diagnostics information. This
information is available in the Logix controller environment.
The PLX51-DLplus-232 uses isolated RS232 for DF1 communication. The RS232 port also uses a
terminal block for convenient installation.
A built-in webserver provides detailed diagnostics of system configuration and operation.

Page 10
1.3 Additional Information
The following documents contain additional information that can assist you with installation and
operation.
Resource
Link
PLX50 Configuration
Utility Installation
www.prosoft-technology.com
User Manual
Datasheet
Example Code & UDTs
www.prosoft-technology.com
Ethernet wiring standard
www.cisco.com/c/en/us/td/docs/video/cds/cde/cde205_220_420/installation/
guide/cde205_220_420_hig/Connectors.html
CIP Routing
The CIP Networks Library, Volume 1, Appendix C:Data Management
Additional Information
For professional users in the European Union
If you wish to discard electrical and electronic equipment (EEE), please contact your dealer
or supplier for further information.
Warning –Cancer and Reproductive Harm –www.P65Warnings.ca.gov