Pulse Secure PSA3000 Montageanleitung

PSA3000 Hardware Guide
Puubblishheed Daatte February 2018
Document Revision 1.1

Copyright © 2014-2018, Pulse Secure, LLC. All rights reserved. All trademarks are the property of their
respective owners. All specifications are subject to change without notice.
Pulse Secure, LLC assumes no responsibility for any inaccuracies in this document. Pulse Secure, LLC reserves
the right to change, modify, transfer, or otherwise revise this publication without notice.
Contacting Pulse Secure:
Pulse Secure, LLC
2700 Zanker Road, Suite 200
San Jose, California 95134
www.pulsesecure.net
© 2018 Pulse Secure, LLC. All rights reserved
2

PSA3000 Hardware Guide
© 2018 Pulse Secure, LLC. All rights reserved
3
Contents
System Overview ..................................................................................................................................5
Introduction...................................................................................................................................................................................................5
LED Control Panel .......................................................................................................................................................................................5
Control Panel Buttons ......................................................................................................................................................................6
Control Panel LEDs ...........................................................................................................................................................................6
Management Port LEDs .............................................................................................................................................................................8
INT and EXT Port LEDs...............................................................................................................................................................................8
Beeping and Alarms ....................................................................................................................................................................................9
Hardware Specifications....................................................................................................................10
System Measurements ........................................................................................................................................................................... 10
Power Rating.............................................................................................................................................................................................. 10
Power Consumption................................................................................................................................................................................ 11
Environmental Requirements ............................................................................................................................................................... 11
Component Specifications ..................................................................................................................................................................... 12
Regulatory Certifications ........................................................................................................................................................................ 12
Mounting in a Rack.................................................................................................................................................................................. 12
Where to Get Replacement Components ........................................................................................................................................ 12
Console and Initial Configuration ....................................................................................................13
Connect Console and Network ............................................................................................................................................................ 13
Power On the System............................................................................................................................................................................. 14
Configure Basic Settings......................................................................................................................................................................... 14
Change the Personality .......................................................................................................................................................................... 16
Access the Web Admin Interface ........................................................................................................................................................ 17
Licensing the System............................................................................................................................................................................... 17
Installation.............................................................................................................................................1
Preparing for Setup.....................................................................................................................................................................................1
Choosing a Setup Location .............................................................................................................................................................1
Physical Rack Precautions ...............................................................................................................................................................2
General Server Precautions ............................................................................................................................................................2
Rack Mounting Instructions ................................................................................................................................................................... 21
Installing the Chassis into a Standard Rack............................................................................................................................. 21
Standard Warnings and Compliance.................................................................................................22

PSA3000 Hardware Guide
© 2018 Pulse Secure, LLC. All rights reserved
4
About Standard Warnings ...................................................................................................................................................................... 22
Safety Certifications ................................................................................................................................................................................. 22
Electrical Safety.......................................................................................................................................................................................... 22
General Safety............................................................................................................................................................................................ 23
Installation Instructions ........................................................................................................................................................................... 27
Circuit Breaker........................................................................................................................................................................................... 28
Power Disconnection Warning ............................................................................................................................................................. 29
Equipment Installation............................................................................................................................................................................. 31
Restricted Area .......................................................................................................................................................................................... 32
Redundant Power Supplies ................................................................................................................................................................... 34
Backplane Voltage..................................................................................................................................................................................... 35
Comply with Local and National Electrical Codes............................................................................................................................ 36
Product Disposal ...................................................................................................................................................................................... 37
Hot Swap Fan Warning ........................................................................................................................................................................... 38
Power Cable and AC Adapter............................................................................................................................................................... 40
Certification Statements ......................................................................................................................................................................... 42
Japan .................................................................................................................................................................................................. 42
Israel .................................................................................................................................................................................................. 42
Saudi Arabia..................................................................................................................................................................................... 42
South Korea ..................................................................................................................................................................................... 42
Taiwan ............................................................................................................................................................................................... 42
Thailand............................................................................................................................................................................................. 43

PSA3000 Hardware Guide
© 2018 Pulse Secure, LLC. All rights reserved
5
System Overview
Introduction
The PSA3000 features a unique and highly-optimized design for low wattage processor platforms. It is
equipped with a high-efficiency 80%+ low noise 200W power supply. High-performance fans provide ample
optimized cooling.
Power switch
Console
Remote
management
Internal port
(INT)
External port
(EXT)
Note: For added system security, the USB port has been disabled.
LED Control Panel
The control panel located on the front of the PSA3000 chassis includes power control buttons and status
LEDs. This section describes the LED indicators and the appropriate responses.

PSA3000 Hardware Guide
© 2018 Pulse Secure, LLC. All rights reserved
6
Control Panel Buttons
The control panel includes a power on/off button and a reset button.
Power: The main power switch is used to apply or remove power from the power supply to the server system.
Turning off system power with this button removes the main power but keeps standby power supplied to
the system. Therefore, you must unplug system before servicing.
Reset: The reset button is used to reboot the system.
Control Panel LEDs
The control panel displays six LEDs to monitor the system.
Information LED: Alerts operator of several states, as noted in the table below:
Status
Description
Continuously on and red
An overheat condition has occurred. This may be caused by cable
congestion.
Blinking red (1Hz)
Fan failure; check for an inoperative fan.
Blinking red (0.25Hz)
Power failure; check for a non-operational power supply.

PSA3000 Hardware Guide
© 2018 Pulse Secure, LLC. All rights reserved
7
NIC1 (GLAN1): Associated with the Management port. It indicates network activity when flashing.
NIC2 (GLAN2): Unused. Will always be off.
HDD: Indicates IDE channel activity or SATA drive activity when flashing.
Power: Indicates power is being supplied to the system power supply. This LED should be illuminated when
the system is operating.
Power Failure: When this LED flashes, it indicates a power failure in the power supply.

PSA3000 Hardware Guide
© 2018 Pulse Secure, LLC. All rights reserved
8
Management Port LEDs
The management port has two LEDs:
The yellow LED indicates activity, while the link LED may be green, amber, or off to indicate the speed of the
connection.
LED
Color
Description
Activity
Yellow (flashing)
Active
Link
Off
No connection
Amber
1 Gbps speed
Green
100 Mbps speed
INT and EXT Port LEDs
Two LAN ports are located on the NIC card. Each Ethernet port has two LEDs:
LED
Color
Description
Activity
Yellow (blinking)
LAN active
Link
Off
10 Mbps link speed or no connection
Orange
1 Gbps link speed
Green
100 Mbps link speed

PSA3000 Hardware Guide
© 2018 Pulse Secure, LLC. All rights reserved
9
Beeping and Alarms
Beep Code
Description
5 short beeps + 1 long beep every 5 seconds
No memory detected in the system
Continuous beep (“i” LED on front panel turns RED)
System overheat condition

PSA3000 Hardware Guide
© 2018 Pulse Secure, LLC. All rights reserved
10
Hardware Specifications
This chapter describes the specifications of your system.
System Measurements
These figures are for an unpackaged system.
Category
Description
Form factor
1U chassis
Width
17.2 inches (43.7 cm)
Height
1.7 inches (4.3 cm)
Depth
9.8 inches (24.9 cm)
Weight
10 lbs (4.5 kg)
Power Rating
Below is the maximum power rating for the power supply:
Category
Description
Input voltage range
100 - 240V
Input current
2.6 Amps maximum
Input wattage
200W
Input frequency range
50 - 60Hz
Inhaltsverzeichnis
Andere Pulse Secure Firewall Handbücher
Beliebte Firewall Handbücher anderer Marken

Lanner electronics
Lanner electronics FW-7650 Series Bedienungsanleitung

Swisscom
Swisscom Internet Backup Bedienungsanleitung

SonicWALL
SonicWALL NSa 5700 Bedienungsanleitung

DPtech
DPtech FW1000 SERIES Bedienungsanleitung

FEITIAN
FEITIAN MultiPass FIDO Bedienungsanleitung

EBLOCKER
EBLOCKER PRO Bedienungsanleitung