QEM HB 237.16 Bedienungsanleitung

User Manual
Supplement to "Installation, maintenance and servicing manual"
POSITION CONTROLLER WITH POSITIVE AND NEGATIVE QUOTAS,
AND MANAGEMENT OF 8 OUTPUTS PROGRAMMABLE WITH UP TO 9
PROGRAMS
HB 237.16
(OHFWURQLF ,QVWUXPHQW
PRG
SET
b237H16

Quality in Electronic Manufacturing
Pag. 2 di 27
HB 237.16
LIST OF SUBJECTS DEALT WITH IN THIS MANUAL
CHAP. 1 - INTRODUCTION
- Supplementary nature of manual 1 - 1
- References 1 - 2
- Responsibility and validity 1 - 3
- Description of operation 1 - 4
CHAP. 2 - OPERATOR/MACHINE INTERFACE
- Description of keyboard 2 - 1
- Description of inputs 2 - 2
- Description of outputs 2 - 3
CHAP. 3 - SETTING UP FOR OPERATION
- Programming (set-up) 3 - 1
CHAP. 4 - USE
- Work programs and auxiliary functions 4 - 1
- Operation graphs and tables 4 - 2
CHAP. 5 - ASSISTANCE
- Inputs and outputs troubleshooting 5 - 1
- How to complete the technical assistance fax form 5 - 2
- Warranty 5 - 3

Quality in Electronic Manufacturing
Pag. 3 di 27
HB 237.16
CHAPTER 1
Supplementary nature of manual
References
Responsibility and validity
Description of operation
INTRODUCTION

Quality in Electronic Manufacturing
Pag. 4 di 27
HB 237.16
1 - 1 SUPPLEMENTARY NATURE OF MANUAL
This manual is to be considered as a supplement to the "Installation, maintenance and servicing manual" which
contains information on wiring, checking and eliminating faults, start-up and maintenance procedures. This manual
gives instructions on the use and correct programming of the instrument.
You are urged, therefore, to read the manual carefully and, if you have any queries, to contact QEM for further
explanations by sending the assistance fax contained in the manual.
1 - 2 REFERENCES
The documentation relative to the instruments designed and sold by QEM has been divided into different booklets for
effective and speedy consultation according to the type of information required.
User Manual
Explanation of software.
This manual gives all the necessary
information for the understanding and
use of the instrument described. The
manual deals with the instrument
software, it gives information on the
understanding, programming,
calibration and use of the instrument
described.
Once the instrument is installed
following the indications given in the
Installation, maintenance and
servicing manual, this user manual
gives all the necessary information
for the correct use and programming
of the instrument.
Installation, maintenance and
servicing manual
All the necessary information for
installation, maintenance and
assistance.
In-depth explanations of all essential
details for correct installation and
maintenance.
The aim is to provide you with valid
and accurate information for the
manufacture of products of
recognised quality and reliability. It is
also a valid support for whoever
needs technical assistance
concerning a machine that includes
a QEM instrument.
Hardware structure
Basic information on the standard
hardware in the series plus
customisation possibilities.
This booklet is enclosed with the
user manual and describes the
hardware configuration for the series
of instruments described.
It also gives the standard electrical,
technical and mechanical
specifications for the series, together
with the possibilities of hardware
customisation in relation to the
different software versions.

Quality in Electronic Manufacturing
Pag. 5 di 27
HB 237.16
Instrument
release
Manual
release
0 0 New manual 01 / 03 / 97
Modifications to manual Date of
modifications
1 - 3 RESPONSIBILITY AND VALIDITY
RESPONSIBILITY
QEM declines all responsibility for any injury to persons or damage to things resulting from the failure to observe the
instructions and rules in this manual and the "Installation, maintenance and servicing manual". It is furthermore
specified that the customer/purchaser is bound to use the instrument according to the instructions provided by QEM
and, if any doubts arise, to send a written query to QEM. Any authorisation for exceptions or substitutions, if contested,
will be deemed valid by QEM only if written consent has been given by QEM.
The reproduction or transfer of all or part of this manual to third parties is forbidden without QEM's written consent.
Any transgression will result in a claim for compensation for the damages sustained.
All rights deriving from patent or designs are reserved.
QEM reserves the right to make partial or complete modifications to the characteristics of the instrument described
and the corresponding documentation.
Objective
The objective of this manual is to give the general rules for the use of the instrument described.
Recommendation
Write down all the instrument setting and programming parameters, keeping them in a safe place to facilitate any future
replacement or servicing operations.
VALIDITY
This manual is applicable to all instruments designed, manufactured and tested by QEM with the same order code.
This document is valid in its entirety, save errors or omissions.

Quality in Electronic Manufacturing
Pag. 6 di 27
HB 237.16
1 - 4 DESCRIPTION OF OPERATION
The instrument HB 237.16 controls the position of one axis and governs the activation and de-activation of 8 totally
programmable outputs. The quotas for each single output can be set in a maximum of 9 programs that can be called
only from the keyboard.

Quality in Electronic Manufacturing
Pag. 7 di 27
HB 237.16
CHAPTER 2
Description of keyboard
Description of inputs
Description of outputs
OPERATOR/MACHINE
INTERFACE

Quality in Electronic Manufacturing
Pag. 8 di 27
HB 237.16
2 - 1 DESCRIPTION OF KEYBOARD
Key Function
Normal operation: Pressed for one second, gives access to choice of program to be
executed.
Data input: confirms the displayed data.
Normal operation: not used.
Data input: resets displayed data to zero.
Normal operation: pressed for two seconds, displays input/output diagnostics.
Data input: increases impulsively or continuously the figure selected on the display (the one
that flashes).
Normal operation: not used.
Data input: moves to the left the selection of the figure displayed.
Lighted when programming set-up parameters.
Lighted when introducing work programs.
Not used.
Not used.
When lighted, indicates possibility of introducing the sign "-".
For adding a value to the count.
Gives access to password-protected functions.
+
+
For introducing work programs.
+
PRG
SET

Quality in Electronic Manufacturing
Pag. 9 di 27
HB 237.16
2 - 2 DESCRIPTION OF INPUTS
Characteristics of inputs
Refer to the chapter entitled "Electrical characteristics" in the "Hardware stgructure" booklet enclosed with this manual.
Name
I1 ON X P1 Programmable input 1. Its function depends on the type of programming made in the "FI" set-up
parameter.
I2 ON X P1 Programmable input 2. Its function depends on the type of programming made in the "F2"set-up parameter.
By holding down together the keys (-) and (ENTER) + password 732, it is possible to set the input acquisition
time.
Polarizer
Operating logic Activation mode
Description
Key
X = See description.
Name
+ Positive transducer supply. Positive voltage supplied by the instrument to feed instrument inputs and transducers.
- Negative transducer supply. Negative voltage supplied by the instrument to feed inputs and transducers.
GND Ground connection. A Ø 4 mm. conductor is recommended.
Vac Instrument supply voltage. Alternating voltage as per code in your order.
Vac Instrument supply voltage. Alternating voltage as per code in your order.
Description

Quality in Electronic Manufacturing
Pag. 10 di 27
HB 237.16
COUNT INPUTS
Name
F1 N / P P1 "Phase 1" input incremental transducer.
F1 N / P P1 "Phase 2" input incremental transducer.
For details of the count inputs, refer to the chapter entitled "Electrical characteristic" in the "Hardware
structure" booklet enclosed with this manual.
PolarizerOperating logic
Description
Key
N = Transducer with NPN logic.
P = Transducer with PNP logic.
2 - 3 OUTPUTS
Output Characteristics
Refer to the chapter entitled "Electrical Characteristics" in the "Hardware structure" booklet enclosed with this manual.
Name
U1 P C1 C Quota 1. With set-up parameter "LI" set on "0", the output is activated when the count reaches the value of
the quota set as parameter "I" in the work program. When the set-up parameter "LI" is set on "1", the output
is de-activated when the count reaches the value of the quota set as parameter "I" in the work program.
U2 P C1 C Quota 2. §With set-up parameter "L2" is set on "0", the output is activated when the count reaches the value
of the quota set as parameter "2" in the work program. When the set-up parameter "L2" is set on "1", the output
is de-activated when the count reaches the value of the quota set as parameter "2" in the work program.
Operating logic Polarizer Activation mode
Description
Key
C = Continuous signal.
P = Programmable in set-up.
Inhaltsverzeichnis