October 9, 2017 7014-285A 3
CB1200 Pellet Insert
Model CB1200 Pellet Insert
Laboratory OMNI Test Laboratories, Inc.
Report No. 061-S-13-2
Type Solid Fuel Room Appliance/Pellet Fuel
Burning Type Insert
Standard ASTM E1509-95, UL127, ULC S628-
93, ULC S610-M87, and ULC/ORD-
C1482-M1990 Room Appliance Pellet
Fuel Burning Type, (UM) 84-HUD.For
use only with palletized wood or shelled
eld corn fuel. Mobile Home Approved
FCC Complies with Part 15 of FCC Rules.
Operation is subject to the following
two conditions: (1) this device may not
cause harmful interference, and (2) this
device must accept any interference
received, including interference that may
cause undesired operation.
The Quadra-Fire CB1200 Pellet Insert meets the U.S. Envi-
ronmental Protection Agency’s emission limits for pellet
inserts sold after May 15, 2015.
This pellet insert needs periodic inspection and repair for
proper operation. It is against federal regulations to operate
this pellet insert in a manner inconsistent with operating
instructions in this manual.
B. BTU & Efciency Specications
EPA Certication #: 972-14
EPA Certied Emissions: 1.3 grams per hour
*LHV Tested Efciency: N/A
**HHV Tested Efciency: N/A
***EPA BTU Output: 11,500 to 34,600 / hr.
****BTU Input: 15,500 to 46,400 / hr.
Vent Size: 3 or 4 inches, “L” or “PL”
Hopper Capacity: 75 lbs.
Fuel Wood Pellets
* Weighted average LHV efciency using data collected during
EPA emissions test.
**Weighted average HHV efciency using data collected during
EPA emissions test.
***A range of BTU outputs based on EPA Default Efciency and
the burn rates from the low and high EPA tests.
****Based on the maximum feed rate per hour multiplied by
approximately 8600 BTU’s which is the average BTU’s from a
pound of pellets.
1 Important Safety Information
NOTE: Hearth & Home Technologies, manufacturer of
this appliance, reserves the right to alter its products, their
specications and/or price without notice.
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage.
For assistance or additional information, consult a qualied
installer, service agency or your dealer.
Quadra-Fire is a registered trademark of Hearth & Home
Technologies.
C. Glass Specications
This appliance is equipped with 5mm ceramic glass. Re-
place glass only with 5mm ceramic glass. Please contact
your dealer for replacement glass.
D. Electrical Rating
115 VAC, 60 Hz, Start 4.1 Amps, Run 1.1 Amps
E. Mobile Home Approved
• This appliance is approved for mobile home installa-
tions when not installed in a sleeping room and when
an outside combustion air inlet is provided.
• The structural integrity of the mobile home oor, ceil-
ing, and walls must be maintained.
• The appliance must be properly grounded to the
frame of the mobile home and use only Listed pellet
vent Class “L” or “PL” connector pipe.
• Outside Air Kit, part 811-0872 must be installed in a
mobile home installation.
NOTE: This installation must conform with local codes. In
the absence of local codes you must comply with the ASTM
E1509-95, UL127, ULC S628-93, ULC S610-M87, ULC/
ORD-C-1482-M1990, (UM) 84-HUD
A. Appliance Certication
• Installation and use of any damaged appliance.
• Modication of the appliance.
• Installation other than as instructed by Hearth & Home
Technologies.
• Installation and/or use of any component part not approved by
Hearth & Home Technologies.
• Operating appliance without fully assembling all components.
• Operating appliance without legs attached (if supplied with
appliance).
• Do NOT Over re - If appliance or chimney connector glows,
you are over ring.
Any such action that may cause a re hazard.
WARNING
Fire Risk.
Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be voided by,
the following actions: