Rational SelfCooking Center SCC Installationsanleitung

Edition: 11-2004
Training Manual
Diagnostic and Troubleshooting
SCC Line from 04-2004
Software 01_07_02 and above
Manual includes changes up to TI 13-2004

General hints:
Part 1: Topic Page:
CM technique
1. CM Overlay I - 04
2. CM Principle I - 05
3. CM Water level control I - 06
4. CM Steam control I - 07
5. CM Key code I - 08
6. CM PCB I - 10
7. CM Sequence of events I - 11
8. CM Service level I - 16
9. CM Diagnostic I - 17
10. CM Running times I - 18
11. CM Basic settings I - 19
12. CM Function test I - 20
13. CM Failure code I - 21
14. CM Gas principle I - 22
15. CM Gas components I - 23
16. CM Change of gas type I - 24
17. CM Table Burner adjustment I - 27
18. CM Setting burner speed I - 28
Training Manual
Diagnostic and troubleshooting
SCC Line from 04-2004
Whenever working on any gas component like:
Gas valve, gas blower and / or changing connected type of gas
a detailed flue gas analysis MUST be done using
adequate CO and CO2measuring equipment!
This shall ONLY be done by trained technicians!
Always check appliance for possible gas leakages!
Isolate the appliance from mains supply
before opening the appliance
When working with chemicals, i.e. aggressive cleaning materials
always wear protective clothing,
goggles, face mask and gloves!
After maintenance / repair the appliance must be checked for electric
safety in accordance with your national, state and local requirements!

Part 2: Topic Page:
SCC Technique
1. SCC Overlay II - 01
2. SCC SelfCooking Control II - 02
3. SCC Combi Steamer mode II - 03
4. SCC Principle II - 04
5. SCC Operator PCB II - 05
6. SCC I/O PCB II - 06
7. SCC Sequence of events II - 07
8. SCC Service level II - 13
9. SCC Diagnostic mode overview II - 14
10. SCC Diagnostic mode II - 15
11. SCC Running times II - 17
12. SCC Basic settings overview II - 20
13. SCC Basic settings II - 21
14. SCC Function test overview II - 24
15. SCC Function test II - 25
16. SCC Service messages II - 27
17. SCC Calibration II - 29
18. SCC Drain valve II - 31
19. SCC Gas principle II - 32
20. SCC Gas technique II - 33
21. SCC Change type of gas II - 34
22. SCC Flue gas analysis II - 35
23. SCC Burner adjustments II - 37
Part 3: Common topics Page:
SCC and CM
1. Software flashing SCC III - 01
2. Software flashing CM III - 02
3. SCC LED code pcb III - 05
4. LED code fan motor SCC and CM III - 06
5. Descaler pump III - 07
8. Installation Checklist III - 09
9. Inspection list III - 13
10. Water Info III - 17

CM Technique from 04-2004
Steam
Hot Air
Combination
Low Temperature Steam
Finishing
Cool Down
Actual Temperature
Display
Timer button
Core Temperature button
Cabinet Temperature Dial
Time - Core Temperature
Display
Time - Core Temperature
Dial
I - 04

B1 Thermocouple interior cabinet
B2 Thermocouple quenching
B3 Thermocouple core temperature
B5 Thermocouple steam generator
F3 Safety thermostat
steam generator 160°C (320°F)
F4 Safety thermostat
interior cabinet 360°C (680°F)
Y1 Solenoid valve filing
Y2 Solenoid valve quenching
M1 Fan motor (without jumper)
M2 Fan motor Top (floor unit only)
with jumper
M4 SC-pump
S2 Level electrode
CM electric from 04-2004
I - 05

Level Control Steam Generator
Center S2 ==> Ground: 2 - 6V AC: water level too low
steam heating must switch OFF
solenoid valve filling ON
Center S2 ==> Ground: 0V AC: water level reached
steam heating can switch ON
solenoid filling switched OFF
Every 2 minutes steam elements will switch off for water level control
Notes:
PCB
VAC
I - 06

Steam Control CM from 04-2004
Intelligent steam control via quenching sensor
1. Filling of interior cabinet
based on time and
temperature control of B1
cabinet sensor
2. After steam saturation
inside cabinet steam will
also fill quenching
chamber
Notes:
3. Depending on the
temperature raise of
quenching sensor B2 the
duration of the next steam
supply is calculated
B2-1: Partial load
B2-2: Full load
4. Interval between steam
supply is depending on the
duration from energizing
steam elements until
reaching set quenching
temperature.
I - 07

1.
A)
B)
C)
D)
E)
F)
G)
H)
I)
2.
A)
B)
C)
D)
E)
F)
G)
3.
A)
B)
C)
D)
E)
F)
Select cleaning program
Cool down cabinet below 60°C
Spray inside cabinet with Rational cleaner
Key Code CM from 04-2004
Open cabinet door
Select "Cool Down"
Press core temperature key for 10 sec.
CLEN "CLEN" will show in cabinet temperature display
Press timer key 1x; Cleaning program starts automatically
(50min)
After end of program, leave cabinet door open over night
Rinse cabinet thoroughly with hand shower
Empty steam generator
(For checking of free drain after each installation and before disconnecting unit for longer period.)
Open cabinet door
Select "Cool Down"
Press core temperature key for 10 sec.
CLEN "CLEN" will show in cabinet temperature display
SC Select "SC" with temperature dial
Close water tap
Press timer key 1x and remain on "Cool Down" position for
about 45 sec.
Select descaling program
Open cabinet door
Select "Cool Down"
Press core temperature key for 10 sec.
CLEN "CLEN" will show in cabinet temperature display
CALC Select "CALC" with temperature dial
Press timer key 1x and follow procedure of the
decalcification instruction.
I - 08

Key Code CM from 04-2004
4.
A)
C)
D)
E)
Change temperature from °C - °F
Select any mode
100°C
212°F
Press timer and core temperature key simultaneously
for 10 sec. until ==>
Notes:
Display changes from °C to °F or vice versa
Release both keys
I - 09

X2 B3 Core temperature
X3 B1 Interior cabinet
X4 B2 Quenching / Steam control
X6 B5 Steam generator
X7 ON - OFF switch
X8 Buzzer
X12 Level electrode
X18 SC - pump
X19 Solenoid valves
X20 Energy optimising
X23 Vent hood
X24 SSR
X27 Door contact switch
X30 Serial interface
X31 BUS / RS 485 interface
X32 Timer / Core Potentiometer
X50 EEPROM
Counting sequence
Notes:
CM PCB - Connections
1
1
1
1
1
1
1
I - 10