U31 Regency Gas Insert
Model U31-NG2 U31-LP2
Fuel Type Natural Gas Propane
Minimum Supply Pressure 5” W.C. (1.25 kPa) 12” W.C. (2.99 kPa)
Manifold Pressure - High 3.8” W.C. (0.95 kPa) 11” W.C. (2.74 kPa)
Manifold Pressure - Low 1.1” W.C. (0.27 kPa) 2.9” W.C. (0.72 kPa)
Orifice Size -Altitude 0-2000 ft. #37 DMS #52 DMS
Orifice Size - Altitude 2000-4500 ft. #40 DMS #53 DMS
Minimum Input
Altitude 0-2000 ft. (0-610m)
14,500 BTU/h
(4.25 kW)
13,700 BTU/h
(4.02 kW)
Minimum Input
Altitude 2000-4500 ft. (610-1372m)
13,000 BTU/h
(3.81 kW)
12,400 BTU/h
(3.63 kW)
Maximum Input
Altitude 0-2000 ft. (0-610m)
30,000 BTU/h
(8.79 kW)
27,500 BTU/h
(8.06 kW)
Maximum Input
Altitude 2000-4500 ft. (610-1372m)
27,200 BTU/h
(7.97 kW)
25,000 BTU/h
(7.33 kW)
Vent Sizing 4” B-Vent 4” B-Vent
Optional
Hearth Trim
Risers
A
C
B
D
1" (25mm)
2" (51mm)
4" (102mm)
6" (152mm)
E
G
F
H
I
Dimension Description U31 Regency
A Faceplate Width 40-1/4” (1022mm)
B Faceplate Height 26-1/4” (667mm)
C Unit Width 27-7/8” (708mm)
D Unit Height 20-1/4” (514mm)
E Unit Depth 13-1/2” (343mm)
F Faceplate to Vent Centerline 11-3/4” (298mm)
G Faceplate Depth 1-3/8” (35mm)
H Height to Vent Collar 20-7/8” (530mm)
I Optional or Standard Front Depth 3-3/4” (95 mm)
U31 Regency Gas Insert
NOTE: This unit may also be installed into new construction using a Zero
Clearance Kit. Please refer to the Zero Clearance Kit Manual for
details.
Approved Venting Systems
Flex Vent Systems: FPI AstroCap™ Flex Vent
Minimum Fireplace Dimensions
The minimum fireplace dimensions for the FPI gas fireplace insert are
shown in the following diagrams:
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaa
aaaaaaaa
aaaaaaaa
aaaaaaaa
aaaaaaaa
aaaaaaaa
L
M
J
K
N
Dimension Description Contour
Faceplate
Molded
Faceplate
J Height 21” (533mm) 21” (533mm)
K Width 26-1/2” (673mm) 29” (737mm)
L Depth 15” (381mm) 16” (406mm)
M Max. Lintel Bar Depth 9” (229mm) 9” (229mm)
N Rear Width 22-1/2” (572mm) 22-1/2” (572mm)
119August 2008 Product Specifications Book
Gas Inserts
Gas Inserts