10 Regency®P36D-1 Zero Clearance Direct Vent Gas Fireplace
INSTALLATION
IMPORTANT MESSAGE
SAVE THESE
INSTRUCTIONS
TheP36D-NG1orP36D-LP1DirectVentFireplace
must be installed in accordance with these
instructions. Carefully read all the instructions in
this manual first. Consult the "authority having
jurisdiction"todeterminetheneedforapermitprior
to starting the installation. It is the responsibility of
the installer to ensure this fireplace is installed in
compliance with manufacturer's instructions and
all applicable codes.
GENERAL SAFETY
INFORMATION
1) The appliance installation must conform with
localcodesor,intheabsenceoflocalcodes,with
the current Canadian or National Gas Codes,
CAN1-B149orANSIZ223.1InstallationCodes.
2) The appliance when installed, must be
electrically grounded in accordance with local
codes,orintheabsence of local codeswiththe
currentNationalElectricalCode,ANSI/NFPA70
or CSA C22.1 Canadian Electrical Code.
3) See general construction and assembly
instructions. The appliance and vent should be
enclosed.
4) This appliance must be connected to the
specifiedventandterminationcaptotheoutside
of the building envelope. Never vent to another
room or inside a building. Make sure that the
vent is fitted as per Venting instructions.
5) Inspecttheventingsystemannuallyforblockage
and any signs of deterioration.
6) Venting terminals shall not be recessed into a
wall or siding.
7) Anysafetyglassremovedforservicingmustbe
replaced prior to operating the appliance.
8) To prevent injury, do not allow anyone who is
unfamiliarwiththeoperationtousethefireplace.
9) Wear gloves and safety glasses for protection
while doing required maintenance.
10) Be aware of electrical wiring locations in walls
andceilingswhencutting holes fortermination.
11) Under no circumstances should this appliance
be modified. Parts that have to be removed for
servicing should be replaced prior to operating
this appliance.
12) Installation and any repairs to this appliance
should be done by a qualified service person.
Aprofessional service person should be called
Emissions from burning wood or gas could
contain chemicals known to the State of
California to cause cancer, birth defects or
other reproductive harm.
INSTALLATION
CHECKLIST
1) Locate appliance
a) Roomlocation(Referto"LocatingYourGas
fireplace" section)
b) Clearances to Combustibles (Refer to
"Clearances" section)
c) MantleClearances(Referto"Combustible
Mantel Clearances" section)
d) Framing & Finishing Requirements (Refer
to "Framing & Finishing" section)
e) Venting Requirements (Refer to "Venting"
section)
2) Assemble Top Standoffs and Top Facing
Support and Side Nailing Strips (Refer to "Unit
AssemblyPriortoInstallation"Section). NOTE:
Must be done before installing unit into place.
3) Install vent (Refer to "Venting" sections).
4) Make gas and electrical connections. Test the
pilot. Must be as per diagram (Refer to "Pilot
Adjustment " section).
Convert to propane if desired (Refer to "Gas
Line Installation" and "Conversion Kit from NG
to LPG" sections).
5) Install standard and optional features. Refer
to the following sections:
a. Optional Brick Panels
b. Log Set Installation
c. Standard Flush Door
d. Regency®Flush or Bay Fronts
e. Hampton®Cast Faceplate
f. Remote Control (Optional)
g. Wall Switch (Optional)
h. Wall Thermostat (Optional)
i. Optional Fan Installation
6) Final check.
toinspectthisapplianceannually.Makeitapractice
to have all of your gas appliances checked
annually.
13) Do not slam shut or strike the glass door.
14) Undernocircumstancesshouldanysolidfuels
(wood, paper, cardboard, coal, etc.) be used in
this appliance.
15) The appliance area must be kept clear and
freeofcombustiblematerials,(gasesandother
flammable vapours and liquids).