Renishaw PHC10-3 PLUS Bedienungsanleitung

General information
© 2012 ‐ 2020 Renishaw plc. All rights reserved.
This document may not be copied or reproduced in whole or in part, or transferred to any other media or language, by any means, without
the prior written permission of Renishaw.
The publication of material within this document does not imply freedom from the patent rights of Renishaw plc.
Disclaimer
RENISHAW HAS MADE CONSIDERABLE EFFORTS TO ENSURE THE CONTENT OF THIS DOCUMENT IS CORRECT AT THE DATE OF
PUBLICATION BUT MAKES NO WARRANTIES OR REPRESENTATIONS REGARDING THE CONTENT. RENISHAW EXCLUDES LIABILITY,
HOWSOEVER ARISING, FOR ANY INACCURACIES IN THIS DOCUMENT.
Trademarks
RENISHAW, the probe symbol used in the RENISHAW logo and REVO are registered trademarks of Renishaw plc in the United Kingdom and
other countries. apply innovation and names and designations of other Renishaw products and technologies are trademarks of Renishaw
plc or its subsidiaries.
All brand names and product names used in this document are trade names, service marks, trademarks, or registered trademarks of their
respective owners.
All trademarks and trade names are acknowledged.
WEEE
The use of this symbol on Renishaw products and/or accompanying documentation indicates that the product should not be mixed with the
general household waste upon disposal. It is the responsibility of the end user to dispose of this product at a designated collection point for
waste electrical and electronic equipment (WEEE) to enable reuse or recycling. Correct disposal of this product will help save valuable
resources and prevent potential negative effects on the environment. For more information, please contact your local waste disposal service
or Renishaw distributor.
Warranty
Renishaw plc warrants its equipment for a limited period (as set out in our Standard Terms and Conditions of Sale) provided that it is installed
exactly as defined in associated Renishaw documentation.
Prior consent must be obtained from Renishaw if non-Renishaw equipment (e.g. interfaces and/or cabling) is to be used or substituted. Failure
to comply with this will invalidate the Renishaw warranty.
Claims under warranty must be made from authorised service centres only, which may be advised by the supplier or distributor.
PHC10-3 PLUS installation guide
www.renishaw.com
Issued 03 2020
2

Care of equipment
Renishaw probes and associated systems are precision tools used for obtaining precise measurements and must therefore be treated with
care.
Changes to Renishaw products
Renishaw reserves the right to improve, change or modify its hardware or software without incurring any obligations to make changes to
Renishaw equipment previously sold.
Packaging
To aid end user recycling and disposal the materials used in the different components of the packaging are stated here:
Packaging component Material 94/62/EC code 94/62/EC number
Outer box Corrugated fibreboard PAP 20
Packing foam Cross-linked Polyethylene LDPE 4
Bag Low density Polyethylene LDPE 4
PHC10-3 PLUS installation guide
www.renishaw.com
Issued 03 2020
3

Product compliance
EU declaration of conformity
Contact Renishaw plc or visit www.renishaw.com/EU for the full EU declaration.
EMC conformity
This equipment must be installed and used in accordance with this installation guide. This product is intended for industrial use only and
should not be used in a residential area or connected to a low voltage power supply network which supplies buildings used for residential
purposes.
FCC (USA only)
Information to user (47 CFR 15.105)
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These
limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to
cause harmful interference, in which case you will be required to correct the interference at your own expense.
Information to user (47 CFR 15.21)
The user is cautioned that any changes or modifications not expressly approved by Renishaw plc or authorised representative could void the
user's authority to operate the equipment.
Equipment label (47 CFR 15.19)
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operation.
PHC10-3 PLUS installation guide
www.renishaw.com
Issued 03 2020
4

REACH regulation
Information required by Article 33﴾1﴿ of Regulation ﴾EC﴿ No. 1907/2006 ﴾“REACH”﴿ relating to products containing substances of very high
concern (SVHCs) is available at:
www.renishaw.com/REACH
China RoHS
Contact Renishaw plc or visit www.renishaw.com/ChinaRoHS for the full China RoHS tabulation.
PHC10-3 PLUS installation guide
www.renishaw.com
Issued 03 2020
5

Safety
If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. There are
no user serviceable parts inside the equipment.
The PHC10-3 head controller is to be used with the provided PSU - Emerson DP4024N3M. See manufacturer's datasheet at
www.emerson.com.
PSU electrical ratings
Supply voltage 100 V - 240 Vac +10% -10%
Frequency range 50 Hz to 60 Hz
Power consumption 49 W max
Transient voltages Installation category II
PHC10-3 is isolated from ac power by disconnection of the IEC mains connector from the supplied PSU. If any additional means of isolation is
required, it must be specified and fitted by the machine manufacturer or installer of the product. The isolator / disconnection device must be
sited within easy reach of the operator and comply with any applicable national wiring regulations for the country of installation.
PHC10-3 PLUS installation guide
www.renishaw.com
Issued 03 2020
6

Environmental conditions
The following environmental conditions comply with those defined in BS EN61010 - 1:2001:
Indoor use IP30 (no protection against water)
Altitude Up to 2000 m
Operating temperature 0 °C to +50 °C
Storage temperature ‐10 °C to +70 °C
Relative humidity 80% maximum for temperatures up to +31 °C
Linear decrease to 50% at +50 °C
Pollution degree 2
PHC10-3 PLUS installation guide
www.renishaw.com
Issued 03 2020
7

References and associated documents
Title Document number
User's guide: Touch-trigger probes H-1000-5021
User's guide: SP25M H-1000-5104
User's guide: HCU2 H-1000-5631
User's guide: AM1 H-1000-4010
Data sheet: AM2 H-1000-2051
Technical specification: Styli and accessories H-1000-3200
Installation guide: PICS H-1000-5000
Installation and user's guide: PH10 PLUS H-1000-7592
PHC10-3 PLUS installation guide
www.renishaw.com
Issued 03 2020
8

Introduction
The guide gives information on physical installation, system connections, communications and interface settings, as well as assistance in fault-
finding during the installation of PHC10-3 PLUS.
WARNING: The components of PH10 PLUS system are not compatible with PH9 or PH20 system components. No attempt should
be made to connect PH10 PLUS system components to a PH9 or PH20 system, as this will result in damage to the product.
The guide should be read in conjunction with the PH10 PLUS series user's guide in order to fully understand the system's features, capabilities
and operation.
The PH10 PLUS series of motorised probe heads can only be used in conjunction with the PHC10-3 PLUS when part of an OEM system
installation. PHC10-3 PLUS has replaced the PHC10-2 and provides support for RS232 and USB communications (IEEE is no longer
supported). PHC10-3 PLUS uses an external power supply for the PH10 PLUS series of heads, manages all the head functions and
communicates via a suitable interface with the CMM's computer. PHC10-3 PLUS does not manage the probe functions but does have the
provision for an interface to be fitted.
Rear panel layout
Key Description
19-way D-type plug for PICS output
29-way D-type connector to HCU2
325-way D-type plug RS232 communications connector to CMM
computer
4USB type “B” socket
5PHC10-3 PLUS configuration switches
615-way D-type connector to probe head
77-pin DIN raw probe connector to probe interface or multiwire input
for internal interfaces
8DC power jack
9Equipment bond point
10 Controller reset button
PHC10-3 PLUS installation guide
www.renishaw.com
Issued 03 2020
9

PHC10-3 PLUS configuration switches
PHC10-3 PLUS switch settings
PHC10-3 PLUS switch Function Up Down
Communications
1# Baud rate
2# Baud rate
3# Baud rate
4*# Stop bit 2 stop bits 1 stop bit
5*# CTS protocol CTS on CTS off
6*# LF protocol LF on LF off
9Command set Extended Basic
Interface
7PICS configuration PPOFF - active during head index PPOFF - inactive during head
index
8HCU1 PROBE/DAMP/RESET Enabled Disabled
10 Probe reset time 2 (extended) 1 (standard)
11 Interface connection PICS / 7 pin DIN 5-pin DIN
12 Output configuration PICS DIN
13 Machine cable isolation Machine cable Multiwire
* Operational only when basic command set selected (switch 9 down).
# Not required for USB operation default position = down.
NOTE: Press the reset button after making switch changes.
Conversion from PHC10-2 to PHC10-3 PLUS
PHC10-3 PLUS is designed to be a plug in functional replacement for PHC10-2. There are some differences which the user needs to be aware
of, the connectors have been rearranged on the rear panel but are of the same type and are labelled in the same way. A USB connector has
been added for those requiring USB communications. Unused switches have been removed and the remaining switches are now grouped in
one row. See the next table for changes.
PHC10-3 PLUS installation guide
www.renishaw.com
Issued 03 2020
10
Andere Handbücher für PHC10-3 PLUS
1
Inhaltsverzeichnis
Andere Renishaw Controller Handbücher

Renishaw
Renishaw UCC T3-2 Bedienungsanleitung

Renishaw
Renishaw UCClite-2 Bedienungsanleitung

Renishaw
Renishaw UCC S5 REVO-2 Bedienungsanleitung

Renishaw
Renishaw UCC MMI Bedienungsanleitung

Renishaw
Renishaw UCC T3 Bedienungsanleitung

Renishaw
Renishaw MCU5 Bedienungsanleitung

Renishaw
Renishaw PHC10-3 PLUS Bedienungsanleitung

Renishaw
Renishaw UCC MMI-2 Bedienungsanleitung

Renishaw
Renishaw UCC T3 PLUS Bedienungsanleitung

Renishaw
Renishaw UCC PI 80 Bedienungsanleitung