Warranty
RKI Instruments, Inc. warrants gas alarm equipment sold by us to be free from defects in
materials and workmanship, and performance for a period of one year from date of shipment
from RKI Instruments, Inc. Any parts found defective within that period will be repaired or
replaced, at our option, free of charge. This warranty does not apply to those items which by
their nature are subject to deterioration or consumption in normal service, and which must be
cleaned, repaired, or replaced on a routine basis. Examples of such items are:
Warranty is voided by abuse including mechanical damage, alteration, rough handling, or
repairs procedures not in accordance with the instruction manual. This warranty indicates the
full extent of our liability, and we are not responsible for removal or replacement costs, local
repair costs, transportation costs, or contingent expenses incurred without our prior approval.
THIS WA R R A N T Y IS EXPRESSLY IN LIEU OF ANY AND ALL OTHER
WARRANTIES AND REPRESENTATIONS, EXPRESSED OR IMPLIED, AND ALL
OTHER OBLIGATIONS OR LIABILITIES ON THE PART OF RKI INSTRUMENTS,
INC. INCLUDING BUT NOT LIMITED TO THE WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT
SHALL RKI INSTRUMENTS, INC. BE LIABLE FOR INDIRECT, INCIDENTAL, OR
CONSEQUENTIAL LOSS OR DAMAGE OF ANY KIND CONNECTED WITH THE
USE OF ITS PRODUCTS OR FAILURE OF ITS PRODUCTS TO FUNCTION OR
OPERATE PROPERLY.
This warranty covers instruments and parts sold to users only by authorized distributors,
dealers, and representatives as appointed by RKI Instruments, Inc.
We do not assume indemnification for any accident or damage caused by the operation of this
gas monitor and our warranty is limited to replacement of parts or our complete goods.
Absorbent cartridges Batteries
Pump diaphragms and valves Filter elements
Fuses

Table of Contents
Chapter 1: Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
About the SDM-03 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
System Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Cautions & Safety Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Chapter 2: Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
AC Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Single-Port AC Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
4-Port AC Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
USB Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Air Filter and Sample Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Instrument Cradle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Back Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Power Jack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Sample Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
PC Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Control Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Chapter 3: Preparing to Use the SDM-03. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Hardware Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Assembling a Manifold for Multiple SDM-03s . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Setting the Operational Parameters in Edit Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Bump Test & Calibration Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Turning on the SDM-03 with an Instrument . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Setting the Bump Test Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Setting the Calibration Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30

Connecting Calibration Gas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Installing the Single Module Data Viewer Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Chapter 4: Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Bump Testing an 03 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Calibrating an 03 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Calibration and Bump Test Records . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Available Memory in the SDM-03 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
Copying Calibration and Bump Test Records. . . . . . . . . . . . . . . . . . . . . . . . . . . .49
Clearing the SDM-03’s Memory. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
Bump Test and Calibration Record Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
Bump Testing or Calibrating and Saving Files to a Flash Drive
Multiple Times in One Day . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
Chapter 5: Single Module Data Viewer Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Launching the Single Module Data Viewer Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Data Viewing Window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53
Using the Single Module Data Viewer Program. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Importing Files Into the Database . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54
Organizing the Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55
Viewing the Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
Deleting Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61
Changing the Password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62
Exiting the Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63
Chapter 6: Spare Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
CAUTION: Read and understand this manual before using the SDM-03. Also read and
understand the GP-03 and OX-03/CO-03/HS-03 Operator’s Manuals.

Chapter 1: Introduction • 5
Chapter 1: Introduction
Overview
This chapter briefly describes the SDM-03 Docking Station and the Single Module Data
Viewer Program. This chapter also describes the SDM-03 Docking Station Standalone
Operation Operator’s Manual (this document). Table 1 at the end of this chapter lists the
SDM-03’s specifications.
About the SDM-03
The SDM-03 Docking Station is an advanced, reliable system that provides calibration, bump
testing, and calibration and bump test records for the 03 Series portable gas monitors. It is
designed to save the calibration and bump test records to a USB flash drive (standalone
functionality) or to be connected directly to a computer (PC controlled functionality). If
calibration and bump test records are stored to a USB flash drive while operating in the
standalone configuration, the Single Module Data Viewer Program can then be used with a
Windows-based personal computer to retrieve calibration and bump test data files from the
USB flash drive or from the computer’s hard drive if the files have been transferred to the hard
drive from the flash drive. If you are using the PC Controller Program while operating in the
PC controlled configuration, you may retrieve instrument data, bump test, and calibrate up to
10 instruments at once. Instrument information and data for each instrument can be viewed
directly using the PC Controller Program and can be printed from the PC Controller Program.
For instructions to use the SDM-03 with the PC Controller Program, see the SDM-03 Docking
Station PC Controlled Configuration Operator’s Manual.
The purpose of this manual is to explain how to set up and use the SDM-03 in Standalone
configuration. It also explains how to use the Single Module Data Viewer Program. You will
learn how to:
• install and launch the Single Module Data Viewer Program
• prepare the SDM-03 for use
• perform a bump test
• perform a calibration
• save calibration and bump test records to a USB flash drive
• view, print, and export calibration and bump test records
CAUTION: The 03 Series detects oxygen deficiency, elevated levels of oxygen,
combustible gases, carbon monoxide, or hydrogen sulfide, all of which can be
dangerous or life threatening. When using the 03 Series, you must follow the
instructions and warnings in the GP-03 and OX-03/CO-03/HS-03 Operator’s
Manuals to assure proper and safe operation of the instrument and to
minimize the risk of personal injury.

6 • Chapter 1: Introduction
CAUTION: The operator of this instrument is advised that if the equipment is used in a
manner not specified in this manual, the protection provided by the
equipment may be impaired.
System Requirements
To use the Single Module Data Viewer Software, your personal computer must meet the
following requirements:
•Operating Systems: Windows® 7, Windows® 8, or Windows® 10.
•Processor: IBM® compatible PC running Pentium® 2 processor or equivalent minimum
•Memory: 32 MB RAM minimum
•Hard Disk Space: 32 MB minimum
• Available USB port

Chapter 1: Introduction • 7
Specifications
Table 1: SDM-03 Specifications
Input Power 12 VDC
NOTE: AC Adapter with 100 - 240 VAC, 50/60 Hz, 0.6A input
and 12 VDC, 1.2A output provided as standard.
Environmental Conditions • For Indoor Use Only
• -10° C to 40° C, below 80% Relative Humidity, Non-
Condensing
Applicable Instruments • GP-03
• OX-03
•CO-03
•HS-03
Memory Capacity 64 KB
Maximum Record Size 256 bytes
Maximum Number of Records
Saved
200
Number of Calibration Gas Cylin-
ders
One calibration gas cylinder per bump test or calibration
Standard Accessories • AC Adapter
• USB Flash Drive
• Single Module Data Viewer Program*
• SDM-GX Docking Station PC Controller Program*
• Inlet Air Filter
• Instruction Manual*
• 10 Foot Long Exhaust Tube
• One 3 Foot Long Tube for GAS Fitting
• 10 Foot Long 3/16 Inch Tube for GAS manifolding
• 2 T-Fittings
• Check Valve
• USB Cable, Type A to Type B
* Not sent with SDM-03. Download from www.rkiinstruments.com/sdm03.

8 • Chapter 1: Introduction
About this Manual
The SDM-03 Docking Station Standalone Configuration Operator’s Manual uses the
following conventions for notes, cautions, and warnings.
NOTE: Describes additional or critical information.
CAUTION: Describes potential damage to equipment.
WARNING: Describes potential danger that can result in injury or death.
Cautions & Safety Information
• Use only polyurethane sample tubing with the SDM-03. Consult RKI Instruments, Inc. for
other materials.
• Do not subject the SDM-03 to infrared or intense light. This may cause communication
errors.
• Do not expose the SDM-03 to water.
• Do not subject the SDM-03 to any hard impact.

Chapter 2: Description • 9
Chapter 2: Description
Overview
This section describes the SDM-03 docking station. It is designed to be used on a table top and
consists of the AC adapter, Type A to Type B USB cable, air filter, check valve, 2 plastic T-
fittings, sample tubing, instrument cradle, back panel, control panel, status LEDs, and 2 USB
ports.
AC Adapter
Single-Port AC Adapter
The single-port AC adapter is a wall plug style adapter with a 5 foot cable. The end of the
cable has a plug that connects to the power jack on the SDM-03’s back panel. The AC adapter
is rated 100 - 240 VAC input, 12 VDC 1.2 A output.
4-Port AC Adapter
The 4-port AC adapter is a wall plug style adapter with four 5-foot cables. The end of each
cable has a plug that connects to the power jack on the SDM-03’s back panel. The AC adapter
is rated 100 - 240 VAC input, 12 VDC 2.0 A output.
To Power Jack
on SDM-03
Back Panel
Figure 1: Single-Port AC Adapter
To Power Jack
on SDM-03
Back Panels
Figure 2: 4-Port AC Adapter

10 • Chapter 2: Description
USB Cable
A Type A to Type B USB cable is provided with the docking station. It is only for use with the
PC Controlled configuration. It is not used in the Standalone configuration.
Air Filter
A cylindrical particle filter with a short length of tubing is supplied with the SDM-03 for
installation to the AIR fitting on the back panel. The filter keeps particulate contamination out
of the docking station.
Sample Tubing
Three types of sample tubes are included with the docking station. One 3 foot length of 3/16
inch ID polyurethane tubing is provided to connect the regulator on a calibration cylinder to
the GAS fitting on the back panel. One 10 foot length of 3/16 inch ID polyurethane tubing is
provided for manifolding the GAS fitting. In addition, a 10 foot length of 5/16 inch ID
polyurethane tubing is provided for connection to the exhaust fitting on the back panel to
allow routing of the exhaust to a location such as an open window where the exhaust can
disperse.
Figure 3: USB Cable
Exhaust Tubing, 5/16 Inch
ID,10 feet
Particle Filter for Air Inlet
Calibration Gas Sample Tubing, 3/16
Inch ID, 3 feet Manifold Tubing, 3/16 Inch
ID,10 feet
Figure 4: Air Filter & Sample Tubing
Andere Handbücher für SDM-03
1
Inhaltsverzeichnis
Andere RKI Instruments Dockingstation Handbücher

RKI Instruments
RKI Instruments SDM-2012 Bedienungsanleitung

RKI Instruments
RKI Instruments SDM-3R Bedienungsanleitung

RKI Instruments
RKI Instruments SDM-3R Bedienungsanleitung

RKI Instruments
RKI Instruments SDM-2012 Bedienungsanleitung

RKI Instruments
RKI Instruments SDM-2012 Bedienungsanleitung

RKI Instruments
RKI Instruments SDM-6000 Bedienungsanleitung

RKI Instruments
RKI Instruments SDM-03 Bedienungsanleitung

RKI Instruments
RKI Instruments SDM-2009 Bedienungsanleitung