Main Function of iDo218
●
●
●
●
●
●
●
●
●
●
●
62 wireless programmable zones. All the zones are defaulted as
alarm zones, and can be changed through programming.
All the zones can be divided into up to 5 partitions, partition 0-4.
Partition 1-4 can be individually armed / disarmed, also set the
daytime for automatically armed / disarmed; partition 0 is special, as
long as arm any one of the partition, partition 0 will be automatically
armed. All zones are defaulted as partition 0.
Build-in a dialer, can alarm to Central Monitor Station and / or the
users' phone numbers through PSTN/DTMF, it is compatible with
Contact ID communication format.
Alarm report can be sent to 4 follow-me phone numbers, or / and 4
central monitor station numbers at the same time. It can report 4
different Central Monitor Stations.
With grade code and duress code: Main Code, Manage Code, User
Code, One-off code and only disarm code.
Up to 127 events log which can be checked on LCD. All the events
can be chosen and sent to central monitor station, but cannot be
deleted.
With build-in recorder can record 20 seconds voice. The record
voice will play 3 times through follow-me numbers when alarm.
Alarm call has priority function.
Build-in siren driver, can drive build-in siren and 15W outside siren.
Matched for up to 10 remote controllers. Arm and Disarm iDo218 by
remote controller;
Arm and disarm iDo218 through line/mobile phone.
,
3