RTC AP22 Betriebsanleitung

PROGRAMMING MANUAL
AP22
012318/18027
RTC-TRAFFIC.COM

TABLE OF CONTENTS
AP22
PROGRAMMING MANUAL
Introduction 1
Installation Overview 1
Programming Features 1
Programming Introduction 2
Programming Sequence 2
Primary Programming Function Keys 3
Programming Instructions 4
Program Time-Of-Day 4
Program the Date 5
Program the Day-Of-Week 6
Program Daylight Saving Time 6
Program Day Plans 7
Clear the Program in a Day Plan 8
Program the Default Week Plan 9
Program Annual Plans 10
Clearing Annual Plans 11
Transfer a Program 12
Manual Control 12
Wiring Harness Color Charts 13
PROGRAMMING RECORDS
Day Plan 1 14
Default Week Plan 14
Annual Plan Record 15

COMMON SCREEN COMMANDS
Instructions 16
Manual Control 16
Set Time 16
Day-Of-Week 16
Daylight Saving Time 16
Annual Plan Programming 16
Day Plan Setup 17
Default Week Plan Setup 17
Date Setup 17
Time Switch Address 17
GPS Status 18
Time Zone 18
Daylight Saving Time (DST) Debug 18
Start Time 18
Modem Time 19
Modem Power 19
View Modem Details 19
Sunrise and Sunset Time 19
Latitude and Longitude 20
Read GPS Coordinates 20
Data Clear 20
Data Transfer 20
Reset the AP22 21
Status 21
Version 21
Clear Annual Plans 21
Clear Day Plans 21
Digital Adjustment 21
Server Connection Information 21
CONVERTING AP22 SOFTWARE TO
RTC CONNECTTM SOFTWARE 22
WARRANTY 23


1
INTRODUCTION
The AP22 is a two-circuit, AC or DC (12VDC) powered, calendar programmable solid state time switch used for switching
electric circuits according to a preset time and date program. The AP22 is primarily designed for school zone and traffic
control use where multiple daily/weekly programs are required on an annual basis.
INSTALLATION OVERVIEW
The AP22 may be attached by using the keyhole tab on the back of the enclosure. Two mounting holes on the inside of the
enclosure and below the circuit board are accessible for additional support.
Outdoor use of AP22 requires installation in a NEMA Type-4 cabinet. Indoor installations do not require a weather-tight
enclosure.
Physical Dimensions: 10.375" H x 4.75" W x 2" D including harness
Weight: approximately 3 pounds
Operating Temperature: -30˚ to +74˚C
PROGRAMMING FEATURES
10 DAY PLANS — Day Plan 1 is the default day plan that will control time switch operation during the normal week timing
plan. The other day plans will control time switch operation for time periods that require a different timing plan with Day Plan
0 being an empty timing plan used for school holidays and weekends.
16 PROGRAM STEPS — Each day plan (1-9) has 16 program steps. The 16 program steps are used to program ON/OFF
times for relay 1 and/or relay 2.
DEFAULT DAY PLAN — The preset day plan that will operate if no other day plans are entered (unless an annual or exception
plan is programmed).
DEFAULT WEEK PLAN — A set of day plans that operate each week unless overridden by an exception plan. The default week
plan permits the assigning of any day plan to each day of the week. The default week plan (1) operates the AP22 every week
of the year. An annual plan program overrides the default week plan program.
ANNUAL PLAN — The AP22 has 36 different annual plans available. Annual plans use an exception-day concept for
programming special events such as holidays, early release days, etc., throughout the calendar.
PROGRAMMABLE DAYLIGHT SAVING TIME ADJUSTMENT — The AP22 automatically adjusts for daylight saving time changes
according to U.S. law. Re-programmable if law changes.
AUTOMATIC LEAP YEAR COMPENSATION — Perpetual type calendar to adjust for the extra day every 4 years
TRANSFER — Allows program data to be transferred from one AP22 to another.
MANUAL OVERRIDE — Allows one or both relays to be manually activated or deactivated from the keyboard. The manual
override will remain in effect until the next programmed step occurs.
AP22 Programming Manual

2
PROGRAMMING INTRODUCTION
Programming the ON/OFF functions of the time switch begin with entering a program step time into a day plan(s).
DAY PLAN — A day plan is the programmed ON/OFF steps for a single day. Each day plan has 16 program steps. Day plans
are assigned to a day of the week in the week plan.
WEEK PLAN — This programming format gives flexibility for having a completely different timing plan for any day of the week.
ANNUAL PLAN — This feature uses an exception-day format that allows the operator to assign any day plan to run anytime
throughout the school calendar. There are 36 annual plan program steps available.
CURSOR — The flashing square character indicating the data entry fields of the AP22. The cursor indicates the data at that
position can be entered or changed by using the AP22 keyboard.
ENTER () — This key is used to finalize every data entry procedure. Pressing the ENTER () key will enter the data at that
position into the AP22 and move the cursor to the next program field.
PROGRAMMING SEQUENCE
1CREATE
DAY PLANS 2CREATE
WEEK PLANS 3CREATE
ANNUAL PLANS
• Choose Day Plan Number
• Choose Step Number
• Choose Time
• Choose to Turn Relay 1
or Relay 2 On or Off
• Choose Day-Of-Week
• Choose Day Plan to Run
for that Day-Of-Week
• Choose Exception
(Annual Plan Number)
• Choose Start Date
• Choose End Date
• Choose Day Plan Number
AP22 Programming Manual

3
PRIMARY PROGRAMMING FUNCTION KEYS
MAIN DISPLAY
EXITENTER
ANNUAL PLAN
DAY PLAN
WEEK PLAN
DATE
AP22 Programming Manual

4
PROGRAMMING INSTRUCTIONS
Programming must begin from the MAIN DISPLAY. The MAIN DISPLAY
shows the DAY, TIME, DATE and RELAY status.
To Return to the MAIN DISPLAY at any time, press the EXIT (#) key.
Press the ENTER () key to “step” through a field without changing
the settings.
PROGRAM THE TIME-OF-DAY
1. From the MAIN DISPLAY, press key 3(TIME) then ENTER ().
2. This brings up the TIME screen.
The cursor will be on the hour field.
Key in the Hour (i.e.: 03 for 3 o’clock) and then ENTER ().
3. The cursor will move to the minutes field.
Key in the Minute (i.e.: 28 for 28 minutes) then ENTER ().
4. The cursor will move to the AM/PM field.
Key 1for AM; 2for PM then ENTER ().
Make sure a common second is being used so the
times are truly synced. hh mm 2=PM
Command? 03
Step 1
Time? 03:28 PM
hh mm 2=PM
Step 2
Time? 03:28 PM
Step 3
Time? 03:28 PM
Step 4
Mon 05:43:23 PM
02/13/15 Rlys --
Main Display
TIME
RELAYS
DAY
DATE
hh mm 2=PM
AP22 Programming Manual

5
PROGRAM THE DATE
1. From the MAIN DISPLAY, press D (DATE) then ENTER ().
2. Key in the Month (ie: 01 for January) then ENTER ().
3. Key in the Day (i.e.: 01 for the first day of the month)
then ENTER ().
4. Key in Year (i.e.: 15 for 2015) then ENTER ().
Command? 0D
Step 1
Date? 01-00-00
Step 2
mm/dd/yy
Date? 01-01-00
Step 3
mm/dd/yy
Date? 01-01-15
Step 4
mm/dd/yy
AP22 Programming Manual

6
PROGRAM DAYLIGHT SAVING TIME (DST)
1. From the MAIN DISPLAY, press 7(DST) then ENTER ().
2. The AP22 will default to the current U.S. standards:
S(Spring), M = 03 (March), SUN = 2(second Sunday)
F(Spring), M = 11 (November), SUN = 1(first Sunday)
The AP22 will automatically default to these times.
To change the month, simply key in the new month and press ENTER ().
To change to another Sunday of the month, key in the Sunday of the
desired month by entering:
1first Sunday
2second Sunday
3third Sunday
4fourth Sunday
5last Sunday
Then press ENTER ().
To disable DST, enter the Spring month as 0.
PROGRAM THE DAY-OF-WEEK
1. From the MAIN DISPLAY, press 4(DAY) then ENTER ().
In all versions of AP22 4.04 or earlier this screen allows the day-of-week
to be set. In CP22 versions the time switch correctly enters the
day-of-week based on the date entered.
2. Press the 4 key to advance the day-of-week, then ENTER ().
The next screen to appear will be the MAIN DISPLAY.
Command? 04
Step 1
Day? Sun
Step 2
Command? 07
Step 1
Step 2
S DST M=03 SUN =2
DEF M=03 S=2
AP22 Programming Manual
Inhaltsverzeichnis