Please read the instructions below thoroughly before putting your Ruby Fires ceramic burner to use. Make sure that the guidelines as
provided are followed.
The Ruby Fires ceramic burner can only be used by people of age, who are competent and who have read and understood these
user’s manual and safety instructions.
Installation of the ceramic burner:
• The ceramic burner is to be placed or hung on a heat resistant foundation or wall.
• When attaching to a wall, we advise to keep a safety distance of minimum 1 cm from the wall in order to ensure a natural fl ow of air.
• Never remove the isolation layer on the backside. Risk of fi re!
• Make sure that during installation the ceramic burner is levelled, both horizontally and vertically. This to make sure that liquid cannot
fl ow out of the burner.
• Keep a safety distance of at least 1 meter (on left-, right- and front side) to objects. Keep fl ammable objects (e.g. curtains, furniture or
bookshelves) away from the Ceramic Burner.
• Do not place the ceramic burner next to, underneath or on top of a windowsill. Risk of fi re!
• Use the ceramic burner only in a draft-free room, otherwise soot can be a result. However, it is important to have suffi cient ventilation.
• Ruby Fires delivers its own unique fuel: Ruby Fires bio ethanol 98% called LEF. The ceramic burner can only function optimally in
combination with this Ruby Fires bio ethanol 98%. Never use another liquid or gel to fi ll or refi ll the ceramic burner: this may cause
blockage of or damage to the ceramic element on the inside of the burner , resulting in fl ames of poor quality. As a consequence, the
warranty expires as well. Exceptions need to be agreed upon by Ruby Fires.
Installation in a Ruby Fires surround:
• Place the ceramic burner in the insert (make sure this is levelled)
Installation in an existing fi replace:
• Place the Ceramic burner in the therefore appointed space (make sure this is levelled) Minimum distance necessary above top of the
burner: 50 cm. Risk of fi re!
Installation of the enclosed glass screens:
• We advise you to use the enclosed glass screens. The glass plates can be installed on the burner with the torques supplied with the
burner. This prevents the fl ames to hit the back (see pictures below). Contact your dealer if fl ames keep on hitting the back.
Installation of the logset/pebbles:
• Ruby Fires has developed a special ceramic log set and pebbles for decoration purposes of the ceramic burner. Place these around
the fi re opening (the (white) ceramic element) of the burner. The fi re opening should remain free. When decoration material is placed
into the fl ames, unnecessary soot will be formed and an unsafe situation may arise. Do not touch decoration material until it has
cooled down for at least 30 minutes. Risk of burns!
• For safety reasons never use any other decoration material for the ceramic burner except the original Ruby Fires ceramic log set or
pebbles. Risk of fi re!
• When placing a ceramic burner against a back wall (e.g. (wall)surround), make sure the fl ames burn vertically at all times. This by
using glass, log set, pebbles or a spoiler. In case the fl ames do hit the back, extinguish the fi re immediately and contact your supplier!
Check our website for different examples.
User’s manual and safety instructions of the unique, patented
Ruby Fires Ceramic Burner a product by Ruby Decor B.V., The Netherlands
Keep this user’s manual carefully for the life of this product. This product is only to be sold in combination with this user’s
manual.

Filling the ceramic burner with Ruby Fires bio ethanol 98% LEF, use only LEF to fill the ceramic burner.
• It is of great importance that the liquid never flows outside the filling opening.
• Make sure to fill the ceramic burner carefully and slowly, so it cannot be overfilled.
• In case liquid is spilled, use a soft, absorbing cloth to clean.
• For an optimal fire the burner has to be filled not higher than 1 cm below the surface of the ceramic element.
When the ceramic burner is filled with LEF for the first time, the ceramic element on the inside will be saturated completely. The liquid
will always remain partly absorbed by the brick. Therefore it is necessary to use more bio ethanol the first time the burner is filled than
the following times.
First filling Refill
Ceramic burner Mini (4114) ± 1 liter ± 0.8 liter
Ceramic burner Small (4120 + Silo) ± 1.5 liter ± 1 liter
Ceramic burner Big (5820) ± 2 liter ± 1,5 liter
Ceramic line Burner (8014) ± 2,5 liter ± 2 liter
How to fill the ceramic burner:
• Open the latch for one third, so the filling-opening is visible. With square burner: open fully.
• Place the enclosed funnel in the filling-opening.
• Carefully pour the Ruby Fires bio ethanol 98% in the funnel until the ceramic brick is saturated, but make sure that the liquid level
remains underneath the surface of the element: at least 1 cm!
• Warning: Make sure that the liquid does not flow outside the filling-opening. In case liquid has been spilled outside the filling-
opening, make sure this is dried up before lighting the fire. Risk of fire! There should never be fire outside the fire-opening. This is
dangerous and can also cause the insert to de-form and damage of the paint of the insert.
• Warning: Keep on filling the burner until the level remains visible in the filling-opening. The level must remain at least 1 cm
underneath the surface.
• When the ceramic burner is filled, remove the funnel. You can now fully open the latch. The burner-opening is visible and the
ceramic burner is ready for use.
Latch open Latch closed
How to re-fill the ceramic burner:
• Close the latch when the ceramic burner is burnt empty.
• Check carefully that there is no longer any fire on the surface.
• Warning: Never fill a burning burner – Life threatening!
• Wait at least 30 minutes for the Bio Flame Burner to cool down.
• For further instructions see: ‘How to fill the ceramic burner”
Lighting the ceramic burner:
• There is a latch for the fire-opening on the topside of the ceramic burner.
• When the ceramic burner is not lit, this latch is closed (to prevent the bio ethanol from evaporating).
• By opening the latch the fire-opening with the ceramic brick becomes visible.
• The ceramic burner can be lit using a long lighter or a long matchstick, but only when nothing is placed on the opening and the
Ruby Fires bio ethanol 98% is well filled as described in: ‘How to fill the ceramic burner’
LEF
LEF

Opening and closing the latch:
The latch can be opened using the enclosed handles.
Maintenance
• When the ceramic burner has been used very often, discolorations on the top can occur. This is normal and does no harm to the
quality of the product.
• Do not use an abrasive product for cleaning the insert. Clean the surfaces with a moist piece of cloth or a non-abrasive stainless
steel cleanser.
• Glass screens can be cleaned with a ceramic cook top cleaner.
Possible problems and solutions:
Changes and/or alterations to the insert, surface or burner are unacceptable and will cause the warranty to expire.
Ruby Fires cannot be held responsible for possible damages or personal injuries caused by misuse or incompetent use of the insert
and ceramic burner.
Important:
• The ceramic burner is to be used for decorative purposes only and not as a primary source of heating.
• Bio ethanol is a hazardous material of dangle level UN 1987, level 3
• The use of the ceramic burner as a multi-burner or open fi re for liquid or solid combustible materials is not permitted.
• The ceramic burner is to be extinguished using the latch on the topside.
• When the ceramic burner is overfi lled there is a risk of spilling the liquid fuel e.g. when it is bumped into. This can cause uncontrolla-
ble fl ames.
• The fl ames cannot be adjusted by using the latch. This should always be completely opened when in use.
• Do not smoke while (re)fi lling or lighting the burner. Risk of explosion!
• Never change the construction of the ceramic burner.
• Warning! Never re-fi ll a hot or warm ceramic burner. Risk of explosion!
• The fl ames should never directly touch the inside of the metal insert.
• Avoid physical contact with the bio ethanol.
• It is prohibited for children, people under the infl uence of alcohol, drugs or medications, or people who are physically or mentally not
in good condition, to use the Ceramic Burner.
• Keep children and pets at a safe distance.
Problem Possible cause Solution
Existence of soot Wrong fuel Use ONLY Ruby Fires bio ethanol 98%
Existence of soot Fire-opening is covered with decoration material Make sure the fi re-opening is free of decoration material
Duration of fi re too short Wrong fuel (e.g. gel) Use ONLY Ruby Fires bio ethanol 98%
Duration of fi re too short Burner has not been fi lled completely Extinguish the burner. Let it cool down for at least
30 minutes and then re-fi ll.
Flames too high Wrong fuel or draft Use ONLY Ruby Fires bio ethanol 98%
Flames too low, not visible Burner has not been fi lled completely Extinguish the burner. Let it cool down for at least
30 minutes and then re-fi ll.
Burner makes a rustling noise Wrong fuel (e.g. gel) or overfi lled Use ONLY Ruby Fires bio ethanol 98%
Flames are blue, not visible Fuel is almost fi nished Extinguish the burner. Let it cool down for at least
30 minutes and then re-fi ll.
Flames remain after the Open the latch and quickly close it again to refrain
latch has been closed the oxygen supply

Vreekesweid 30-32
1721 PR Broek op Langedijk Tel.: (+31) (0)226 - 33 14 20 E-mail: info@rubyfires.com
The Netherlands Fax: (+31) (0)226 - 33 14 29 Website: www.rubyfires.com
• Be careful with inflammable clothes or hair.
• Do not blow into the fire.
• Never leave the fire unattended.
• Do not place inflammable material e.g. paper, cardboard, fabric (clothes) etc. on the burner or surround.
• Keep the latch closed when the burner is not in use.
• The use of the ceramic burner for burning any other material besides the Ruby Fires bio ethanol is not permitted
• Warning! In case the flames hit the back of the insert extinguish the fire immediately and contact your supplier.
• Keep a fire-extinguisher or extinguishing blanket within reach.
Ventilation of the room:
When the ceramic burner is used in closed spaces, adequate ventilation has to be provided! In addition to carbon dioxide (CO2) an
adequate supply of fresh air (150 cm² opening) should be ensured. Insufficient ventilation can cause poisoning by the odourless carbon
monoxide. There are requirements for the supply of fresh air quantity per fire:
The room must be a minimum area of 25 m² and has to be ventilated at least 1/hr.
Type burner Content Measurem. Heat room consumpt. Burning time
(liters) (cm) (kW) (m2) (ltr p. hr.) (hours)
4114 1 41x14x8 ca. 2 min 25 0,30 3
4120 + Silo 1,5 41x20x8 ca. 2,5 min 25 0.32 3
5820 2 58x20x8 ca. 3 min 35 0.47 4
8014 2 80x14x8 ca. 3,5 min 35 0.49 3,5 / 4
Attention!! Temperature of glass and metal screens placed in front of the fire can reach 90°-140°C and top of the bio burner
even 200°C, when the burner is in use!
Warranty
The warranty on this product is 2 years. Any changes on the surface or inside of the ceramic burner, due to the usage of the product,
are not included in the warranty of the ceramic burner.
Ruby Fires reserves the right to make any technical alterations in order to improve the product and its characteristics / safety.
Ruby Fires would like to thank you for the purchase of the ceramic burner. If all the instructions are carefully followed, the ceramic bur-
ner will burn free of soot and scent.
Inhaltsverzeichnis
Andere Ruby Fires Kamin im Innenbereich Handbücher

Ruby Fires
Ruby Fires Elski Bedienungsanleitung

Ruby Fires
Ruby Fires Mystic Fires MF1520C Bedienungsanleitung

Ruby Fires
Ruby Fires Mystic Fire RF20 Bedienungsanleitung

Ruby Fires
Ruby Fires VARESE Bedienungsanleitung

Ruby Fires
Ruby Fires Serra Bedienungsanleitung

Ruby Fires
Ruby Fires MYSTIC FIRES RF40 Bedienungsanleitung

Ruby Fires
Ruby Fires Mystic Fire RF 10 Bedienungsanleitung

Ruby Fires
Ruby Fires MF1620C Bedienungsanleitung

Ruby Fires
Ruby Fires TF1560G Bedienungsanleitung

Ruby Fires
Ruby Fires MF1535H Bedienungsanleitung