Samson 5007-2 Series Service-Handbuch

Translation of original instructions
EB 9511 EN
Firmware version 1.03.11
Edition January 2021
SAM Connect Gateway (Type5007-2)

Note on these mounting and operating instructions
These mounting and operating instructions assist you in mounting and operating the device
safely. The instructions are binding for handling SAMSON devices. The images shown in
these instructions are for illustration purposes only. The actual product may vary.
ÎFor the safe and proper use of these instructions, read them carefully and keep them for
later reference.
ÎIf you have any questions about these instructions, contact SAMSON‘s After-sales Service
(aftersalesservice@samsongroup.com).
Documents relating to the device, such as the mounting and operating
instructions, are available on our website at www.samsongroup.com >
Service & Support > Downloads > Documentation.
Denition of signal words
Hazardous situations which, if not avoided,
will result in death or serious injury
Hazardous situations which, if not avoided,
could result in death or serious injury
Property damage message or malfunction
Additional information
Recommended action
DANGER
!
WARNING
!
NOTICE
!
Note
Tip
EB 9511 EN

Contents
EB 9511 EN
1 Safety instructions and measures ................................................................1-1
1.1 Notes on possible property damage.............................................................1-3
2 Markings on the device ..............................................................................2-1
2.1 Nameplate .................................................................................................2-1
2.2 Firmware versions.......................................................................................2-2
2.3 Article code................................................................................................2-3
3 Design and principle of operation ...............................................................3-1
3.1 CongurationusingtheTROVIS-VIEWsoftware ............................................3-4
3.2 Versions .....................................................................................................3-4
3.3 Device overview and operating controls........................................................3-4
3.4 Option modules..........................................................................................3-6
3.5 Power supply unit with standby power supply (SPS) .......................................3-6
3.6 Technical data ............................................................................................3-7
3.7 Dimensions in mm.....................................................................................3-10
3.7.1 Dimensions for mounting (mm)...................................................................3-11
4 Shipment and on-site transport ...................................................................4-1
4.1 Accepting the delivered goods .....................................................................4-1
4.2 RemovingthepackagingfromtheSAMConnectGatewayandmodules .........4-1
4.3 TransportingtheSAMConnectGateway.......................................................4-1
4.4 Storing the gateway....................................................................................4-1
5 Installation.................................................................................................5-1
5.1 Installation conditions..................................................................................5-1
5.2 Preparation for installation...........................................................................5-1
5.3 Setting up the optional additional functions...................................................5-1
5.3.1 Inserting option modules..............................................................................5-2
5.3.2 Setting up the standby power supply (SPS)....................................................5-4
5.4 MountingtheSAMConnectGateway...........................................................5-6
5.5 Establishingelectricalconnections ................................................................5-6
6 Operation..................................................................................................6-1
6.1 Capacitive keys...........................................................................................6-1
6.2 Display ......................................................................................................6-2
7 Start-up and conguration..........................................................................7-1
7.1 Settings ......................................................................................................7-2
7.1.1 Setting the user level....................................................................................7-2
7.1.2 Setting the language ...................................................................................7-3
7.1.3 Activating password protection ....................................................................7-3

Contents
EB 9511 EN
7.1.4 Setting the local power line frequency...........................................................7-4
7.1.5 Performing option module settings................................................................7-4
8 Operation..................................................................................................8-1
8.1 Remotedatatransmission ............................................................................8-1
8.1.1 StatusLEDsoftheGSMmodule....................................................................8-1
8.1.2 Improving the signal quality.........................................................................8-1
9 Malfunctions ..............................................................................................9-1
9.1 Troubleshooting ..........................................................................................9-1
10 Servicing..................................................................................................10-1
10.1 Firmware updates .....................................................................................10-1
10.2 Periodic inspection and testing of the gateway.............................................10-1
11 Decommissioning .....................................................................................11-1
12 Removal ..................................................................................................12-1
12.1 Removingtheoptionmodule......................................................................12-1
12.2 Removingthegateway ..............................................................................12-1
13 Repairs ....................................................................................................13-1
13.1 ReturningdevicestoSAMSON ..................................................................13-1
14 Disposal...................................................................................................14-1
15 Certicates...............................................................................................15-1
16 Annex A (conguration instructions)..........................................................16-1
17 Annex B...................................................................................................17-1
17.1 Accessories ..............................................................................................17-1
17.2 After-sales service.....................................................................................17-1

EB 9511 EN 1-1
Safety instructions and measures
1 Safety instructions and measures
Intended use
ThemodularSAMConnectGatewayallowstheinputofsignals(4to20mA),forexample
issuedbyexternaltransmitters.Furthermore,theintegratedGSMmoduleallowsremotedata
transmission.
Thedeviceisdesignedtooperateunderexactlydenedconditions(e.g.supplyvoltage,
temperature). Therefore, operators must ensure that the device is only used in operating
conditionsthatmeetthespecicationsusedforsizingthedeviceattheorderingstage.
SAMSON does not assume any liability for damage resulting from the failure to use the
deviceforitsintendedpurposeorfordamagecausedbyexternalforcesoranyother
externalfactors.
ÎRefertothetechnicaldataforlimitsandeldsofapplicationaswellaspossibleuses.
Reasonably foreseeable misuse
TheSAMConnectGatewayisnot suitable for the following applications:
−Useoutsidethelimitsdenedduringsizingandbythetechnicaldata
Furthermore, the following activities do not comply with the intended use:
−Use of non-original spare parts
−Performing maintenance activities not described in these instructions
Qualications of operating personnel
Thedevicemustbemounted,startedupandservicedbyfullytrainedandqualiedpersonnel
only; the accepted industry codes and practices are to be observed. According to these
mounting and operating instructions, trained personnel refers to individuals who are able to
judgetheworktheyareassignedtoandrecognizepossiblehazardsduetotheirspecialized
training,theirknowledgeandexperienceaswellastheirknowledgeoftheapplicable
standards.
Personal protective equipment
No personal protective equipment is required for the direct handling of the SAM Connect
Gateway.Workintheplantmaybenecessarythatrequirespersonalprotectiveequipment.
ÎCheck with the plant operator for details on personal protective equipment.

1-2 EB 9511 EN
Safety instructions and measures
Revisions and other modications
Revisions,conversionsorothermodicationsoftheproductarenotauthorizedbySAMSON.
Theyareperformedattheuser'sownriskandmayleadtosafetyhazards,forexample.Fur-
thermore, the product may no longer meet the requirements for its intended use. Use of the
device is no longer permitted in this case.
Warning against residual hazards
To avoid personal injury or property damage, operators and operating personnel must pre-
venthazardsthatcouldbecausedinthedevicebytakingappropriateprecautions.Plantop-
eratorsandoperatingpersonnelmustobserveallhazardstatements,warningandcaution
notes in these mounting and operating instructions, especially for installation, start-up and
service work.
Responsibilities of the operator
Operators are responsible for proper use and compliance with the safety regulations. Opera-
tors are obliged to provide these mounting and operating instructions to the operating per-
sonnel and to instruct them in proper operation. Furthermore, operators must ensure that op-
eratingpersonnelorthirdpartiesarenotexposedtoanydanger.
Responsibilities of operating personnel
Operating personnel must read and understand these mounting and operating instructions as
wellasthespeciedhazardstatements,warningandcautionnotes.Furthermore,theoperat-
ing personnel must be familiar with the applicable health, safety and accident prevention
regulations and comply with them.
Referenced standards, directives and regulations
DeviceswithaCEmarkingfullltherequirementsoftheDirectives2014/53/EUand
2011/65/EU.
The'Certicates'sectioncontainsthisdeclarationofconformity.
Referenced documentation
The following documents apply in addition to these mounting and operating instructions:
−OperatingInstructions(SAMConnectGateway–CongurationwithTROVIS-VIEW)
uEB9511-2
−Mountingandoperatinginstructionsforconnectedcomponents(Media5,Media6)

EB 9511 EN 1-3
Safety instructions and measures
1.1 Notes on possible property damage
NOTICE
!
Risk of fatal injury due to electric shock (230V version).
ÎBeforeconnectingwiring,performinganyworkonthedeviceoropeningthede-
vice, disconnect the voltage supply and protect it against unintentional reconnection.
ÎOnly use power interruption devices that are protected against unintentional recon-
nection of the power supply.
Risk of damage to the electronics due to the incorrect connection of the electrical
power supply.
TheSAMConnectGatewayisdesignedtooperateunderexactlydenedelectricalcon-
ditions.
ÎObserve the permissible tolerances of the supply voltage.
ÎFor wiring, you are required to observe the relevant regulations concerning device
safety and electromagnetic compatibility.
Risk of damage to the device due to incorrect mounting position.
ÎMount the device in the upright position only.
Incorrect installation and removal of option modules will damage the SAM Connect
Gateway.
ÎBeforeinsertingorremovingtheoptionmodules,disconnectthesupplyvoltage.
Risk of malfunction due to incorrect power line frequency setting.
Thelocalpowerlinefrequencymustbeenteredtobeabletoproperlylteroutanydis-
turbanceswhicharetransmittedovergroundwiresorexternalpowersupplyunits.
ÎSet the local power line frequency by selecting the corresponding parameters.
The use of unapproved batteries will damage the SAM Connect Gateway.
ÎDonotuserechargeablebatteriesintheSAMConnectGateway.
Risk of device damage due to foreign particles entering it.
ÎDonotremovethepackagingandprotectivelm/protectivecapsuntilimmediately
before mounting and start-up.

1-4 EB 9511 EN

EB 9511 EN 2-1
Markings on the device
2 Markings on the device
2.1 Nameplate
1 Signal range
2Electricpowersupply
3 Model number
4 Firmware version
5CongurationID
6 Serial number1)
SAMSON 5007 - 2
SAMSON AG, Germany
Made in Germany
Output Supply
Model 5007 -
SAM Connect Gateway
See technical data for ambient temperature
Firmware
Serial no.
Var.-ID
1 2
3
4
5
6
1) Thersttwoguresoftheserialnumberinreverseorderindicatetheyearof
manufacture(example:serialnumber71xxxxxÎYear of manufacture = 2017).
2) 15-digitserialnumberforuniqueidenticationofmobiledevices
2
SAMSON 5007-1 Option module [GSM]
IMEI:
Activation-Code:
GSM Module
Model
1
4
3
1InternationalMobileEquipmentIdentity1)
2 Model number
3 Activation code
4QRcode
GSM module:
SAMSON 5007 Option module
2
1
Option module:
1 Abbreviation of optional additional function
2 Optional additional function

2-2 EB 9511 EN
Markings on the device
2.2 Firmware versions
Firmware revisions
Old New
1.02.07 1.03.09
• Newversion:230Vversion
• Increased measuring accuracy of the analog inputs
• RussianandTurkishaddedasmenuanddisplaylanguage
• Start-upwizardadded
• Improved operation
• Four-gurecodetoprotectthegatewaysettings
1.03.09 1.03.11
Internal revisions
Inhaltsverzeichnis
Andere Samson Tor Handbücher
Beliebte Tor Handbücher anderer Marken

LST
LST M500RFE-AS Bedienungsanleitung

Kinnex
Kinnex Media Gateway Bedienungsanleitung

2N Telekomunikace
2N Telekomunikace 2N StarGate Bedienungsanleitung

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries Superlink SC-WBGW256 Bedienungsanleitung

ZyXEL Communications
ZyXEL Communications ZYWALL2 ET 2WE Bedienungsanleitung

Telsey
Telsey CPVA 500 - SIP Bedienungsanleitung