schroff VME64x Bedienungsanleitung

VME64x System Subrack 2 U
User’s Manual
Product No.:
20836-245
July 14, 2009
Doc-No: 63972245_R1.0

Impressum:
Schroff GmbH
D-75334 Straubenhardt, Germany
The details in this manual have been carefully compiled and
checked - supported by certified Quality Management System
to EN ISO 9001/2000
The company cannot accept any liability for errors or misprints.
The company reserves the right to amendments of technical
specifications due to further development and improvement of
products.
Copyright © 2009
All rights and technical modifications reserved.
Rev. Date updated Change
R1.0 July 14, 2009 Initial Release

VME64x System Subrack 2 U
20836-245
www.schroff.biz I R1.0, July 14, 2009
Table of Contents
1 Safety................................................................................................................. 1
1.1 Intended Application............................................................................................ 1
1.2 Safety Instructions............................................................................................... 2
1.2.1 Safety Symbols used in this document.................................................. 2
1.3 General Safety Precautions................................................................................. 2
1.4 References and Architecture Specifications........................................................ 3
2 Product Definition............................................................................................. 4
2.1 Subrack System Overview................................................................................... 4
2.2 VME64x Backplane ............................................................................................. 5
2.3 Power Backplane................................................................................................. 5
2.4 Power Supply....................................................................................................... 6
2.4.1 Grounding/Earthing................................................................................ 6
2.4.2 Plug-In AC Power Supply (Order separately)........................................ 7
2.4.3 Wiring Diagram...................................................................................... 8
2.5 Cooling................................................................................................................. 9
3 Assembly......................................................................................................... 10
3.1 General Assembly Guidelines ........................................................................... 10
3.1.1 Unpacking............................................................................................ 10
3.1.2 Ensuring Proper Airflow....................................................................... 10
3.2 Rack-Mounting................................................................................................... 11
4 Service............................................................................................................. 12
4.1 Technical support and Return for Service Assistance....................................... 12
4.2 Declaration of Conformity.................................................................................. 12
4.3 Delivery comprises ............................................................................................ 13
4.4 Accessories ....................................................................................................... 13
4.5 Replacement Parts............................................................................................ 13
5 Technical Data ................................................................................................ 14
6 Dimensions ..................................................................................................... 15

VME64x System Subrack 2 U
20836-245
www.schroff.biz II R1.0, July 14, 2009

VME64x System Subrack 2 U Safety
20836-245
www.schroff.biz 1 R1.0, July 14, 2009
1 Safety
1.1 Intended Application
The VME64x system subrack, described in this manual, is intended as a
platform for a microcomputer system based on the VME64x bus system
(VITA 1.1-1997).
The VME64x system subracks are designed for protection class IP 20 and can
be used only in the resp. environments.
For higher protection requirements, a.e. IP 54/55 you must install the system
subrack in a protective case.
VME64x system subracks are not finished products, so there is no valid
approval for these units. In order to enable stand-alone functionality, additional
elements are required. An operational system is achieved only by way of
appropriate VME64x boards.
The completion and final testing of the units have been carried out, or at least
supervised, by qualified technicians. These instructions are directed exclusively
to these qualified technicians i.e.engineers, trained and qualified electricians
etc.
Make sure that:
• the assembled unit complies with the safety regulations currently applicable
in the country it is going to be used.
• the overall unit complies with all other regulations and specifications at the
place and country of use, e.g. interference limits, approval by the telecom-
munications authorities.

VME64x System Subrack 2 U Safety
20836-245
www.schroff.biz 2 R1.0, July 14, 2009
1.2 Safety Instructions
The intended audience of this User’s Manual is system integrators and
hardware/software engineers.
1.2.1 Safety Symbols used in this document
1.3 General Safety Precautions
• Service personnel must know the necessary electrical safety, wiring and
connection practices for installing this equipment.
• Install this equipment only in compliance with local and national electrical
codes.
Hazardous voltage!
This is the electrical hazard symbol. Familiarise yourself with the danger of
electrical voltages and the safety precautions to avoid accidents before
starting to work with parts that carry dangerous voltages.
Caution!
This is the user caution symbol. It indicates a condition where damage of the
equipment or injury of the service personnel could occur. To reduce the risk of
damage or injury, follow all steps or procedures as instructed.
Danger of electrostatic discharge!
Static electricity can damage sensitive components in a system. To avoid
damage, wear ESD wrist straps or at regular intervals touch blank enclosure
parts.
Warning!
Voltages over 60 VDC can be present in this equipment. This equipment is
intended to be accessed, to be installed and maintained by qualified and
trained service personnel only.
This equipment is designed in accordance with protection class 1!
It must therefore be operated only with protective GND/earth connection!

VME64x System Subrack 2 U Safety
20836-245
www.schroff.biz 3 R1.0, July 14, 2009
1.4 References and Architecture Specifications
• User Manual VME64x Backplanes
Order no.: 73972-103
• Short Form User Manual VME64x J1/J2 Monolithic Backplanes
Order no.: 73972-128
• Short Form User Manual Power Backplane 23098-115
Order no.: 73972-072
• Operating Instructions maxpowerPRO 250 W Power Supply 13100-141
Order no.: 73972-077
• Operating Instructions Fan Monitoring Module
Order no.: 63972-302
Further information can also be found in the catalogue „Electronic Packaging“
and on the internet under www.schroff.biz

VME64x System Subrack 2 U Product Definition
20836-245
www.schroff.biz 4 R1.0, July 14, 2009
2 Product Definition
The Schroff VME64x System Subrack consists of:
• A shielded 2 U 19“ subrack with front and rear card cage for 4 VME64x
6 U boards in accordance with VME64x standard (VITA 1.1-1997) and two
slots for optional 250 W plug-in power supplies
• A 4 slot 6 U VME64x (VITA 1.1-1997) backplane
• A power backplane with two P47 connectors
• Fan Tray with two fans and a fan monitoring module for the active cooling of
the boards and the power supplies
• Power input module with IEC 320-C14 connector, mains/line switch, mains/
line filter and fuses
2.1 Subrack System Overview
Figure 1: Subrack System Overview
The2 U19” steelchassis isblack powdercoated (RAL9005)andEMC shielded.
The board cage enables the horizontal assembly of 4 VME64x front boards (6
U, 4 HP, 160 mm deep) and 4 Rear I/O Boards (6 U, 4 HP, 80 mm deep).
The right guide rails of the board cage are equipped with ESD clips.
10009833
1 Front board cage with guide rails 4 Power Supply (order separately)
2 Fan Tray 5 Slot for an additional power supply,
covered with a 3 U / 8 HP front panel
3 Power input module with IEC 320-C14
connector, mains/line switch, mains/
line filter and fuses
6 Rear board cage with guide rails

VME64x System Subrack 2 U Product Definition
20836-245
www.schroff.biz 5 R1.0, July 14, 2009
2.2 VME64x Backplane
The horizontally assembled 6 U backplane (J1.J2 Monolithic) with P0
connectors conforms to:
VITA 1.1-1997
VITA 38 systems management for VME
At the right side is a connector for the power supply, at the left side a connector
for the Fan Tray.
Further information can be found in the user manual of the backplane:
Order-No. 73972-103, in the catalogue or on the internet at www.schroff.biz
2.3 Power Backplane
A Power Backplane (23098-115) is located to the right of the VME64x
Backplane providing two P47 connectors to connect to 3 U / 250 W plug-in
power supplies. The Power Backplane distributes the supply voltages to the
VME64x Backplane.
For more information see the Backplane’s User Manual, Order No.: 73972-072,
in the catalogue and at www.schroff.biz

VME64x System Subrack 2 U Product Definition
20836-245
www.schroff.biz 6 R1.0, July 14, 2009
2.4 Power Supply
The VME64x system can be powered by plug-in power supplies with wide range
input (100 - 240 VAC), Schroff order-no. 13100-141.
The power supplies can be plugged-in in dedicated slots at the right front side.
The power supplies contact via 47-position connectors to the power backplane.
The power input is provided by a AC mains/line module with IEC 320-C14
connector, integrated mains/line fuses and line filter.
The fuse rating is 8 A slow blow.
Figure 2: AC Terminal - Grounding
2.4.1 Grounding/Earthing
There is a 6,3 mm faston connector at the rear panel. This connector is only for
equipotential bonding. Grounding is achieved through the protective earth
conductor of the power cable!
Hazardous voltage!
Parts of the power supply may be exposed with hazardous voltage. Always
remove mains/line connector before carry out any assembly work.
Caution!
Your system has not been provided with a AC power cable. Purchase a
AC power cable that is approved for use in your country. The AC power cable
must be rated for the product and for the voltage and current marked on the
product's electrical ratings label. The voltage and current rating of the cable
should be greater than the ratings marked on the product.
10009832
1 Fuseholder 3 AC Connector (IEC320-C14)
2 Mains/line switch 4 6,3 mm faston connector
Caution!
The unit is designed inaccordance with protection class 1! It must therefore be
operated with protective earth/GND connection. Use only a three conductor
AC power cable with a protective earth conductor that meets the IEC safety
standards!
Inhaltsverzeichnis