1. Safety Instructions 5
2. Introduction 6
3. Features 7
4. Technical Specifications 8
5. Front Panel Controls 10
6. Operating Instructions 12
General Information
Safety
Operating Conditions
Operation
7. Functional Checks 11
8. Warranty 13
9. List of Accessories 13

Scientech 4077A
3
Safety Instructions
Read the following safety instructions carefully before operating the instrument. To
avoid any personal injury or damage to the instrument or any product connected to it.
Do not operate the instrument if suspect any damage to it.
The instrument should be serviced by qualified personnel only.
For your safety:
Use proper Mains cord : Use only the mains cord designed for this instrument.
Ensure that the mains cord is suitable for your
country.
Ground the Instrument : This instrument is grounded through the protective
earth conductor of the mains cord. To avoid electric
shock the grounding conductor must be connected to
the earth ground. Before making connections to the
input terminals, ensure that the instrument is properly
grounded.
Observe Terminal Ratings : To avoid fire or shock hazards, observe all ratings and
marks on the instrument.
Use only the proper Fuse : Use the fuse type and rating specified for this
instrument.
Use in proper Atmosphere : Please refer to operating conditions given in the
manual.
1. Do not operate in wet / damp conditions.
2. Do not operate in an explosive atmosphere.
3. Keep the product dust free, clean and dry.

Scientech 4077A
4
Introduction
The Scientech 4077A Multiple Power Supply has been designed as a constant
current (CC) and constant voltage (CV), source for laboratories, industries and field
testing applications, featuring low power loss, compact and lightweight. It provides
three floating independent DC output voltages and is ideally suitable for complex
analog and digital testing.
The DC outputs 0- 32V and 0 ±15V Dual Track, can be continuously adjusted, with
coarse and fine controls. The other DC output 5V also can be adjusted between 4.0V
and 6.0V. Current limit is also adjustable for all outputs. Any over loading for
adjusted current limit, is indicated by OR LED. When the maximum setting is crossed
or the overheating has occurred, the OR LED will lit up.
Two displays (one 3-digit display for voltage & other 3-digit for current) are used to
read the instantaneous values. These two displays can be switched simultaneously for
either of the DC outputs. It has low residual ripple and noise, as well as excellent line
and load regulation. The Scientech 4077A Multiple Power Supply is provided with
all protective circuits to ensure trouble free operation

Scientech 4077A
5
Features
Three floating, independent DC supply voltages
DC Outputs
A: 0 -32V, 2A
B: 5V, 5 Amps
C: 0 ± 15V (Dual Tracking) /1A each
Constant voltage and constant current operation
Short circuit protection
Digital display for voltage and current
Adjustable current limiter

Scientech 4077A
6
Technical Specifications
DC Output : A: 0-32V, 2A
B: 5V (4.0V to 6.0V), 5A
C: 0 to ± 15V Dual Tracking, 1A
DC Output A
DC Output : 0-32V, continuous variable by means of coarse & fine
controls
Output Current :2A (maximum)
Current Limit : Adjustable between 100 mA to 2A
DC Output B
DC Output : 5V, adjustable from 4.0V –6.0V for specific
applications.
Output Current : 5A (maximum)
Current Limit : Adjustable between 100mA to 5A
DC Output C
DC Output : 0 to ± 15V, adjustable by means of coarse and fine
controls
Output Current : 1A
Current Limit : Adjustable between 100mA to 1A
Tracking Error : ± (0.1 % + 5mV)
Other Information for all : (32V/2A, 5V/5A, ± 15V/1A)
outputs
Setting Resolution : Voltage: 10mV
Current: 2mA
Internal Resistance : ≤15mΩ
Stability :≤ 2.5mV
Recovery Time : ≤ 50 s
Load & Line Regulation : ≤ 0.05%
Temperature Coefficient : ≤ 0.05% + 5 mV/ C
Ripple & Noise : ≤ 1mVrms
Display : 3digits for voltage, 3 digits for current LED indication
for voltage & current
Accuracy : ± (1% rdg + 1 dgt)

Scientech 4077A
7
General Information:
Built in over voltage, overload, overheat & short circuit protection.
All outputs are floating.
Insulation:
Between chassis and :> 10 MΩ at 100VDC
output terminal
Between chassis :> 50 MΩ at 500VDC
and AC plug
Power Supply : 230 V AC ± 10% 50Hz
Operating Conditions : 0 - 400 C; 90% RH
Dimension : W 285 x H 75x D 385 mm
Weight : 5.5 Kgs. (approximately)
(Subject to Change)

Scientech 4077A
8
Front Panel Controls
Figure 1
1Power: Push button switch for supplying power to instrument.
2A: 0 - 32V (4mm banana terminals): Output terminals for 4mm banana
plugs or cable connection. The output voltages are short circuit protected.
3B: 5V (4.0V –6.0V) (4mm banana terminals): Output terminals for 4mm
banana plugs or cable connection for 5V output. The output voltages are
short circuit protected.
4C: 0 - ±15V Dual Tracking (4mm banana terminals): Output terminals
for 4mm.banana plugs or cable connection. 0 to + 15V output is "Master"
and 0 to -15V output is "Slave", which tracks the output voltage of Mater.
The output voltages are short circuit protected. .
5 & 17 Coarse (adjusting knob): For the coarse setting of the output voltages at A
& C respectively. Adjustment range: 0-32V and 0 - ±15V respectively.
6 & 18 Fine (adjusting knob): For the fine settings of the output voltage for A & C
output terminals. Adjustment range approximately 2.1V & 1V respectively.
7 & 16 I max (Adjusting knob): For current limit setting of the outputs A & C
respectively. Adjustment range 100mA -2A & 20mA - 1A each.
8 & 14 Digital Display (7-segment LED): 3-digit readout for output voltage and
3-digit readout for output current.

Scientech 4077A
9
94.0V –6.0V:Adjustment for setting the output voltage of the source B from
4.0V to 6.0V.
10 & 15 V & A Indicators: Two LEDS indicate the unit of the display.
11 I max: For current limit setting of the output B Adjustment range 100mA -
5A.
12 Select Display (Push Buttons): Four push buttons can be pressed one at a
time. When pressed each selects both displays (Voltage & Current)
simultaneously for the respective voltage source to show the instantaneous
values.
13 ORA, ORB, ORC-, ORC+ (Overload indicators): LEDs for overload
indication for respective DC outputs are provided. In case of overheating or
output current in excess of set limit corresponding OR LED lits up.
19. Reset Switch: The output voltage is cut off during the conditions of
overload. By pressing the Reset switch, the normal operating conditions are
restored.

Scientech 4077A
10
Operating Instructions
General Information:
The logical front panel layout of Scientech 4077A makes it easy to become familiar
with the operation of the instruments. However, even experienced users should read
the following instructions thoroughly before using the instrument.
After unpacking the instrument, check for any mechanical damage or loose parts
inside. Should there be any transportation damage, inform the supplier immediately
and do not put the instrument into operation.
Safety:
The case chassis and all measuring parts are connected to the protective earth contact
of the inlet. The mains plug shall only be inserted in a socket outlet provided with a
protective earth contact. The protective action must not be negated by the use of an
extension cord without a protective Conductor.
Warning !
Any interruption of the protective conductor inside or outside the instrument or
disconnection of the protective earth terminal is likely to make the instrument
dangerous. Intentional interruption is prohibited. The mains/line plug should be
inserted before connections are made to measuring circuits.
When removing the metal case or replacing, the instrument must be completely
disconnected from the mains supply. If any measurement or calibration procedures are
unavoidable on the opened-up instrument, these must only be carried out by qualified
personnel acquainted with the danger involved.
Operating Conditions:
The ambient temperature range during operation should be between 0° - 40°C; 90%
RH and should remain within -20°C & + 70°C during transportation or storage. The
operational position is optional; however, the ventilation holes on the Scientech
4077A must not be obstructed. Prior to calibration a preheat run of approximately 30
minutes is required.
First Time Operation:
After unpacking the instrument check for any mechanical damages. The instrument
should be plugged in mains-plug of proper mains supply 230V ± 10%. Switch on the
instrument. The power ‘On’ is indicated by lighting of displays.
Operation:
The Multiple Power Supply Scientech 4077A has three electrically isolated supply
voltages. This permits easy series connection of output voltages. In case of series
connection the maximum output voltage increases with a maximum current of 2Amp.
In the dual tracking supply, the negative (slave) Power Supply tracks the positive
(master) supply voltage with 1% tracking error. The current limit setting is also
common for both due to overload, if "Master" output voltage falls. The "Slave" will
track it. But if "Salve" gets overloaded "Master" will not track the "Slaves" output
voltage.
Inhaltsverzeichnis