Sculpt AXIS Bedienungsanleitung

1
1. PREFACE
2. SPECIFICATIONS AND CLEARANCES
3. PRELIMINARY INSTALL GUIDE
4. ZERO CLEARANCE ASSEMBLY
5. INSTALL GUIDE
6. OPERATION & MAINTENANCE
7. TEST REPORT
8. WARRANTY
9. FINAL WORDS
I1000IB ZERO CLEARANCE
INSTALLATION & USER GUIDE
AXIS
NOTICE TO INSTALLER:
These instructions must be left with the owner, who should keep them for future use.

2
COMPLIANCE PLATE AND SERIAL NUMBER.
The instructions in this manual are recommendations only, the distributor and manufacturer bears no liability to the interpretation of these instructions.

3
Thank you for choosing Sculpt Fireplaces as your heater of choice.
Your replace is the result of careful design, artisan engineering and safety tests.
If it is properly installed, used and maintained, you may be sure that you will have an outstanding
heating feature in your home for years to come.
We advise you to read through this guide in order to become acquainted with the installation
methods specic to your replace.
It is recommended that this replace be installed by a qualied and licensed trades professional.
You will nd in this guide the answers to most of your questions, should you require further
assistance we recommend you contact your retailer.
Before igniting your replace for the rst time, please carefully read this manual.
Follow @sculptreplacecollection on Instagram, SculptFireplaceCollection on Facebook and be
sure to post your latest masterpiece installed with the hashtag #sculptres.
We hope we’ve helped make you the envy of your friends this winter and years to come.
From all of us,
Sculpt Fireplace Collection
CONGRATULATIONS!

4
IMPORTANT
*Heating capacity of the following appliances are a guide only and refers to areas with 2.4m ceilings
and 6 or more star rated buildings. Heating output may vary depending on factors such as building
characteristics, quality of insulation and type of rewood used and climate zone.
All dimensions shown are approximate. Check all dimensions accurately prior to installation. In line with
our policy of continuous improvement, we reserve the right to alter specications without notice.
All units comply and MUST be installed to Australian & New Zealand Standard AS/NZS 2918:2001.
When in use some parts may become hot, a suitable re guard is recommended where very young,
elderly or inrm are concerned.
THE AXIS I1000IB UNIT IN THIS MANUAL CONFORMS TO AUSTRALIAN AND NEW ZEALAND STANDARDS
AS/NZS 2918;2001 DOMESTIC SOLID FUEL BURNING APPLIANCES & AS/NZS 4012/4013(2014).
The instructions in this manual are recommendations only, the distributor and manufacturer bears no liability to the interpretation of these instructions.

5
INSTALLATION GUIDE
AXIS I1000IB ZERO CLEARANCE
This wood heater must be installed according to standard trade practices(as per AS/NZS 2918:2001),
according to the manufacturer’s instructions, in addition to local and national regulations (the most
restrictive of the regulations are applicable). This appliance must be installed by a qualied and licensed
professional.
The manufacturer is only an equipment designer and the following elements are not part of it’s
prerogatives:
• the design of heating installations
• thermal studies
• the creation of networks of heating distribution ducts
These are the domain of professional installers possessing the required qualications.
This appliance was designed and built in compliance with Australian and New Zealand standards. It
has been tested by an independent laboratory in order to validate the installation and commissioning
parameters. Any alterations to the appliance may cause a hazard and will void any warranties.
AXIS wood heaters are not work site incinerators. The combustion of any materials not listed in this
manual (pg, 18) may damage the appliance’s components.
1. PREFACE

6
2. SPECIFICATIONS
AXIS I1000IB Zero clearance
Solid steel rebox with re bricks
Up to 15-30 Squares*
1.2g/kg
66%
Secure Swing door opening system
3.6m
200mm, 250mm, 300mm
Recommended for well insulated homes
10 year rebox & rebrick warranty**
180kg
Width: 1220mm Depth: 700mm Thickness: 25mm (***refer pg, 7)
Material
Heating Capacity
Avg Emissions
Avg Efciency
Glass Door
Minimum Flue Height
Flue Dimensions
Optional outside Air Kit
Warranty
Weight
Minimum Hearth Dimensions***
*Heating capacity of the following appliances are a guide only and refers to areas with 2.4m ceilings
and 6 or more star rated buildings. Heating output may vary depending on factors such as building
characteristics, quality of insulation, type of rewood used and climate zone.
**See warranty pg, 21 of the manual
100
50,65
58,8
Ø20
33,5
83
100
50,65
58,8
Ø20
33,5
83
FRONT SIDE
483mm
1100mm
830mm
340mm
720mm
OVERALL ZERO CLEARANCE BOX DIMENSIONS

7
2. SPECIFICATIONS
MUST READ
This appliance and flue were tested at the following clearances.
The Axis I1000IB and z/c box was tested in a combustible enclosure in a manner conforming to joint
Australian/New Zealand Standard 2918:2001, Appendix B. The sides and rear of the wall enclosure must
be no closer than 50mm from the sides and rear of the appliance zero clearance box. The front wall of
the enclosure must be made of a non-combustible material to a height of 300mm above the appliance
fascia and must extend to 100mm either side of the appliance fascia. The rst internal wall stud of the
appliance must also be made of a non-combustible material.
IMPORTANT MANTEL SHELF: Mantel shelf and mantle upright clearance was not tested and should
be installed as per cleause 3.4.1.3 (b) of AS/NZS2918:2001
A minimum 520mm deep X 1100mm wide and 25mm thick floor protector (Skamotec board or similar)
should be used under the appliance. The floor protector/hearth should also extend a minimum 1220mm
wide X 700mm deep X 25mm thick (Skamotec board or similar) must be used in front of the appliance
(see joint AS/NZS 2918:2001 3.3.2).The floor protector must extend 700mm in front of the fuel loading
door and be placed centrally in the 1220mm width.
PLEASE NOTE:A minimum 50mm air gap must be maintained around the outer triple skin flue skin in
the ceiling of the enclosure
Clearances & Hearth- Axis I1000IB Z/C
SIDE FRONT
TOP
*All diagrams are not to scale
50MM AIR GAP
MIN 1220MM
520MM 700MM
50MM AIR GAP
300MM
NON-COMBUSTIBLE
NON-COMBUSTIBLE
FIRST STUD
NON-COMBUSTIBLE
MATERIAL
NON-COMBUSTIBLE
MATERIAL
50MM AIR GAP
25MM
FLOOR PROTECTOR
(MUST BE A FULLY
SUPPORTED BASE)

8
It is the users duty to make themselves aware of and apply all national or more restrictive local
standards and instructions(AS/NZS 2918:2001).
IMPORTANT
Prior to unpacking and installation ensure the appliance has not been damaged during transit. Please
ensure you check the glass, the door(s), the damper operation and the door locking mechanism
Before any work is carried out, as per local and national regulations and laws, this appliance MUST be
installed by a licensed professional as per Australian and New Zealand Standards 2918:2001.
IMPORTANT WARNING
Any exception or altercations beyond this manual and Australian & New Zealands Standards AS/NZS
2918:2001 is a health and safety hazard which will result in a non-compliant installation and a void of
warranties.
Electrical cables and components must not be placed in the vicinity of the appliance as it is a re
hazard.
3. PRELIMINARY INSTALL GUIDE

9
For the installation and use of this appliance, the tter and the user should strictly adhere to local
and national regulations in addition to Australian & New Zealand Standards AS/NZS 2918:2001. The
installer should comply with the instructions and recommendations detailed in this manual. Safety and
operation of the replace is directly dependent thereon. The liability of the manufacturer can neither be
retained nor assured following failure of installation or incorrect use which does not comply with AS/
NZS 2918:2001.
As each installation is unique, a qualied and licensed trades professional should take all required
preliminary precautions depending on the technical elements inherent to each job.
In-observance of the assembly instructions in conjunction with AS/NZS 2918:2001 entails the liability
of the person who carries it out.
As a result of faulty assembly, irrational use of parts or additional components that were not supplied
by the manufacturer, and/or modifying of the appliance or components will result in inferior or unsafe
operation. Should this occur the manufacturer bears no liability, and will result in a null and void product
warranty.
PRELIMINARY INSTALL INFORMATION
All images and diagrams in this manual are for installation reference purposes only and are not to
scale, the distributor and manufacturer bears no accuracy of these images and accepts no liability. The
purpose of these images and diagrams is to act as a guide in conjunction with the written components,
and are NOT to be used to instruct independently. The order of steps listed in this manual are
recommendation only.
It is strongly recommended that the licensed trade professional who is performing the installation of
this appliance, completely read and comprehend all instructions in this manual prior to proceeding.
Sculpt Fireplaces & Axis reserves the right to change these specications without prior notice.
PLEASE READ PRIOR TO INSTALL
ACCEPTABLE VARIANCE ALLOWANCE
Due to the production of these hand assembled and manufactured replaces, there is an acceptable
allowance of 3-5mm variance of the unit, including the door frame. This variance in production is non-
claimable under any warranties.
HEAT RESISTANT & NON COMBUSTIBLE MATERIALS
Heat resistant materials must meet AS/NZS 2918:2001 clause 1:5.21 a material with an allowable
service temperature of 600° Celsius or greater.
3. PRELIMINARY INSTALL GUIDE

10
4. ZERO CLEARANCE ASSEMBLY
ZERO CLEARANCE ASSEMBLY GUIDE
STEP 1: LAY ALL PARTS ON THE FLOOR
Lay parts on the flue to ensure that all required components
have been received.
Check list:
1 x Top panel
1 x Back panel
1 x Base panel
2 x side panels
1 x Inner spigot
1 x Outer spigot
Screws not included.
STEP 2: ASSEMBLE BASE & SIDE PANELS
Begin by assembling the left and right side panels to the base
panel. Using the provision holes on each panel as a guide, use
screws to rmly secure all three panels into place
The two square tubes on the base of the zero clearance box
must be facing upright, the rebox is to sit directly onto these
tubes.
STEP 3: ASSEMBLE TOP PANEL
Place the top panel onto the top of the side panels and screw
into position using the provision holes.
Place the inner and outer spigots onto top of the hole cut out in
the top panel and screw into position.
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Andere Sculpt Kamin im Innenbereich Handbücher

Sculpt
Sculpt SEGUIN MULTIVISION HYDRO 80 Bedienungsanleitung

Sculpt
Sculpt AXIS Series Bedienungsanleitung

Sculpt
Sculpt SEGUIN Aurore Bedienungsanleitung

Sculpt
Sculpt AXIS I1000 Bedienungsanleitung

Sculpt
Sculpt JC BORDELET Tatiana 997 Bedienungsanleitung

Sculpt
Sculpt AXIS 1000 Bedienungsanleitung

Sculpt
Sculpt Seguin Europa 7 Bedienungsanleitung