Intruder alarm system
ENROLLING
1
Ser v ic e m ode
System setup
Enable the wireless zone by changing Not used
loop type to any other loop type. If the system uses a
keypad produced before 2014, an installer is
obligated to change the loop type to NO/DEOL or
Vibration.
Advance to the next unlearned zone with keypad
keys [Ü] or [7].
1
Z01 D o o r
Name Door
3
System setup
Zones
Z01 D o o r
Loop ty p e NO/DEOL
3
Z01 D o or
WL det. l o o p ( zone) ID 2 01
4
Z01 D o o r
Address 0 6 _ 1
3
Enter the zone address in MA_Z format, where MA
is a module address in the system and Z is a zone
number in the module.
Note: for wireless zones MA_1 – MA_8 the system
will automatically assign NO/DEOL loop type and
for wireless zones MA_9 – MA_16 the Vibration
loop type. Don't change the loop type of a zone!
Module address:
EXT116S - address 06 (default) or given during
the registration process;
Virtual module EXT116S address depends on the
control panel's type:
P16 - address 12;
P32 - address 12 and 13;
P64 - address 12, 13, 14 and 15.
Enter wireless detector’s loop (zone) ID number
and press the [ENT] key to start enrolling. This field
may also be used for deleting the sensor from the
module.
Done
Wai tin g for
WL detector
Wireless detector successfully enrolled. No
additional transmissions are needed for
confirmation.
BK1
BK4
Use Supports Wireless detector loop (zone) ID number
Built-in reed switch
(used in conjunction
with a magnet)
200
255
Normally closed
circuit contact loop
wired to ...
Roller detector
loop wired to ...
Vibration detector
loop wired to ...
BK3
BK2**
BK4
210
211
111
... input 1
... input 1
220
221
121
... input 2
... input 2
230
231
131
... input 3
... input 3
212
112
222
122
232
132
213 223 233
215 225 235
217 227 237
219
...
118
119
229
...
128
129
239
...
138
139
Zone response (speed) time of 0,4 sec.
211 - last digit of identification code defines the
number of Roller pulses.
111 - last digit of identification code number x 10
defines the zone response (speed) time (example: 1 x
10 = 10 msec).
Temperature
sensor BT1
BK3
BK2**
BV3
BK4
... input 1 ... input 2 ... input 3
BV3
Delete the detector
in a particular zone
Delete all
detectors in a
specific wireless
module
All
All
201
254
** wireless detector loop (zone) ID number for input 3 is not used.
Installation manual
BK1, BK2, BK3, BV3, BK4 and BT1 Wireless detectors
Wireless detector loop (zone) enrolling ID numbers
When enrolment has started, immediately press the
detector's battery for a short period of time (~1 sec)
as shown in the picture. You will feel a light click after
pressing the battery. The tamper switch is now
activated and the detector will transmit a tamper
message.
Page 2
Please act according to your local rules and do not dispose of your unusable alarm system or its components with other household waste. This
product utilization in EU is covered by European Directive 2002/96/EC.
Kodinis Raktas UAB, manufacturer of SECOLINK Intruder Alarm System, offers a Warranty for a term of twenty-four months. It declares, that
product BK1 complies with essential EU directives and EU standards EN 50131-1, Grade 1, Environmental Class II;
EN 50131-2-6. For more information visit manufacturer’s website www.kodinis.lt or www.secolink.eu for a complete text of declaration.
SECOLINK Intruder Alarm System is designed and manufactured in Lithuania.
SYSTEM COMPLIANCE AND WARRANTY
Rev.30/11/16_KF