Secure Care Advantage 500DE Bedienungsanleitung

Doc No.: A05160691 REV Q ECO 12425 Date: 03/27/17
Installation Manual
SMT Advantage
500DE System
39 Chenell Drive
Concord, NH USA 03301-8501
Phone: (800) 451-7917 / (603) 223-0745
Fax: (603) 227-0200
http://www.securecare.com
© 2009 Secure Care Products®, LLC
CONTENT IS SUBJECT TO CHANGE WITHOUT NOTICE
FOR THE LATEST UPDATED MANUALS PLEASE VISIT AND LOG INTO THE DISTRIBUTOR PORTAL AT
WWW.SECURECARE.COM
Please contact your
Distributor /
Installer for service …
Tel.: ___________________________

Doc No.: A05160691 REV Q ECO 12425 Date: 03/27/17 2
TABLE OF CONTENTS
SECTION 1 IMPORTANT NOTICES.................................................................................... 5
SECTION 2 SYSTEM BLOCK DIAGRAM............................................................................ 8
SECTION 3 INSTALLATION AND CONNECTIONS............................................................ 9
Power Supply for Exit Panel ............................................................................................................................................... 10
SECTION 4 TYPICAL INSTALLATION.............................................................................. 11
SECTION 5 SPECIFICATIONS .......................................................................................... 12
SECTION 6 SYSTEM COMPONENTS............................................................................... 13
Flush Mount Box.................................................................................................................................................................. 14
Surface Mount Box............................................................................................................................................................... 15
SECTION 7 STANDARD FEATURES................................................................................ 16
SECTION 8 INSTALLATION AND CONNECTIONS.......................................................... 17
Single or Double Magnetic Door Contact Connections..................................................................................................... 17
Normally Open Push Button (P/N A04150900) Connections............................................................................................ 17
Remote Keypad Connections............................................................................................................................................... 18
Electromagnetic Lock Connections .................................................................................................................................... 19
Delayed Egress Switch Connections ................................................................................................................................... 20
Multiple Panel Fire Alarm Connections............................................................................................................................. 21
Connecting Multiple SMT Advantage 500DE Exit Panels to the Fire Alarm Control Panel........................................ 22
Sounder Connections ........................................................................................................................................................... 22
4 & 8 Channel Nurse Station Connections......................................................................................................................... 23
LED Nurse Station Annunciator......................................................................................................................................... 23
A02030901 (A02040901)....................................................................................................................................................... 23
SECTION 9 PROGRAMMING INSTRUCTIONS ................................................................ 24
Basic Panel Operation.......................................................................................................................................................... 24

Doc No.: A05160691 REV Q ECO 12425 Date: 03/27/17 3
Panel Initialization ............................................................................................................................................................... 24
Changing Access Code ....................................................................................................................................................... 24
Arm or Disarm Panel .......................................................................................................................................................... 24
PM Mode Enable/Disable ................................................................................................................................................... 24
Delayed Egress Settings ....................................................................................................................................................... 25
Delayed Egress Activation Time......................................................................................................................................... 25
No Code/ Irreversible Delayed Egress................................................................................................................................ 25
PM Programming Options .................................................................................................................................................. 26
Same arm and disarm times seven days a week:................................................................................................................. 26
Same arm and disarm times during the week, but the weekend is armed 24 hours: ........................................................... 27
Program the panel to have different programs for different days (one per day): ................................................................ 27
Latching Fire Alarm ............................................................................................................................................................ 28
Life Safety Lock.................................................................................................................................................................... 28
Software Version .................................................................................................................................................................. 28
SECTION 10 TESTING THE PARAMETER ACCESS CONTROL..................................... 29
SECTION 11 TESTING THE MAGNETIC LOCK CONTROL............................................. 30
RECOMMENDED WEEKLY TESTS............................................................................................................................... 30
Testing the Escort and Anti-tailgate Features ................................................................................................................... 30
Testing the Remote Keypad................................................................................................................................................. 30
Testing the Remote Push Button......................................................................................................................................... 30
RECOMMENDED WEEKLY TESTS............................................................................................................................... 31
Testing the Escort and Anti-tailgate Features ................................................................................................................... 31
Testing the Delayed Egress feature..................................................................................................................................... 31
Testing the Door Status feature........................................................................................................................................... 31
Testing the Remote Keypad................................................................................................................................................. 31
Testing the Remote Push Button......................................................................................................................................... 31
RECOMMENDED MONTHLY TESTS............................................................................................................................ 31
Testing the Fire Alarm Release feature.............................................................................................................................. 31
RECOMMENDED ANNUAL SERVICE .......................................................................................................................... 31
Battery Replacement............................................................................................................................................................ 31
SECTION 12 REPLACEMENT PARTS LIST..................................................................... 32
SECTION 13 COMPLIANCE STATEMENTS..................................................................... 33

Doc No.: A05160691 REV Q ECO 12425 Date: 03/27/17 4
SECTION 14 GENERAL PRODUCT WARRANTY ............................................................ 35
1. Notices................................................................................................................................................................................. 35
2. LimitedWarranty............................................................................................................................................................... 37
3. Limitations of Liability....................................................................................................................................................... 38
4. Governing Law and Arbitration........................................................................................................................................ 38
5.Severability.......................................................................................................................................................................... 39
6.Waiver................................................................................................................................................................................. 39
APPENDIX A CALIFORNIA FIRE MARSHALL LISTINGS.................................................. 40
APPENDIX B CARD ACCESS INPUT MODE.................................................................. 41
TABLE OF FIGURES
Figure 2-1 System Block Diagram 8
Figure 3-1 Power Requirements 9
Figure 6-1 Exit Panel, Front View 13
Figure 6-2 Exit Panel, Rear View 13
Figure 6-3 Flush Mount Back Box 14
Figure 6-4 Surface Mount Box 15
Figure 8-1 Push Button Connections 17
Figure 8-2 Remote Keypad Connections 18
Figure 8-3 Lock Connections 19
Figure 8-4 Electromagnetic Lock Connections 19
Figure 8-5 Egress Switch Connections 20
Figure 8-6 Two Egress Switch Connections 20
Figure 8-7 Fire Alarm System Connections 21
Figure 8-8 Multiple Panel and Fire Alarm Control Panel Connections 22
Figure 8-9 Sounder Connections 22
Figure 8-10 Single or Double Nurse Station Connections 23
Figure 8-11 Nurse Station Front View 23

Doc No.: A05160691 REV Q ECO 12425 Date: 03/27/17
SECTION1 IMPORTANT NOTICES
PLEASE READ THIS MANUAL BEFORE BEGINNING
1.
2.

SECTION1 IMPORTANT NOTICES
Doc No.: A05160691 REV Q ECO 12425 Date: 03/27/17 6
3.
4.
5.
6.
7.

SECTION1 IMPORTANT NOTICES
Doc No.: A05160691 REV Q ECO 12425 Date: 03/27/17 7
8.
9.
10.

Doc No.: A05160691 REV Q ECO 12425 Date: 03/27/17
Typical Installation Wiring Diagram
Figure 2-1 System Block Diagram
SECTION2 SYSTEM BLOCK DIAGRAM
2 wire output from relay
(A04150900)
A41010901)
(A41010901)
(422)
2 wires from Separate central or wall mount power supply
supplied to lock under 500DE control
7 conductor ribbon cable
2 wire input from door switch
2 wire input from push button
2 wire input from egress switch
2 wires from central or wall mount power
supply
SMT Advantage
500DE
(A05160910)
Magnetic Lock with Integrated
Egress Switch
Magnetic Door
Switch
External
Keypad
Push Button
Switch
12v 1.6A
Power
Supply
12v 1.6A
Power
Supply
4 or 8 Channel LED
Nurse Station, Power
Sounder or other customer
supplied peripheral
activated by relay closure.

Doc No.: A05160691 REV Q ECO 12425 Date: 03/27/17
SECTION3 INSTALLATION AND CONNECTIONS
NOTE: A Secure Care approved central power supply (A40020901) may be used in place of wall mount
power supplies
A non switched 110VAC (overseas 220AC) duplex outlet (2A) is required within 12 feet (3.7 meters) of each
SMT Advantage 500DE Exit location if a wall mount power supply is used.
The SMT Advantage 500DE Exit Panel can be powered from an optional wall mount local power supply or aa
central power supply may be used to power several SMT ADV 500 DE Exit Panels. The use of emergency power
circuits is highly recommended.
NOTE: Do not extend the power supply cord attached to the wall mount supply. The
maximum distance the duplex outlet should be from the SMT Advantage 500DE Exit Panel is 12
feet (3.7 meters).
Figure 3-1 Power Requirements

SECTION3 INSTALLATION AND CONNECTIONS
Doc No.: A05160691 REV Q ECO 12425 Date: 03/27/17 10
Power Supply for Exit Panel
8 FUSED OUTPUTS
12VDC 8AMP POWER SUPPLY
INPUT AC
VOLTAGE
BATTERY
CONN.
- +- +
12VDC BATTERY
BATTERIES MUST BE WIRED IN
PARALLEL
REFER TO THE MANUFACTURER'S
INSTALLATION MANUAL BEFORE
INSTALLING POWER SUPPLY
Risk of shock
Dry location use only
For indoor use only
Power wire is UL requirement. Failure to use this wire removes UL Listing.
Power Wire 14/2 Stranded shielded Plenum wire.
12VDC BATTERY
BATTERIES MUST BE WIRED IN
PARALLEL
Andere Handbücher für Advantage 500DE
1
Inhaltsverzeichnis
Andere Secure Care Sicherheitssystem Handbücher
Beliebte Sicherheitssystem Handbücher anderer Marken

EDM
EDM Solution 6+6 Wireless-AE Bedienungsanleitung

Highway Safety Group
Highway Safety Group EA401 Bedienungsanleitung

Siren
Siren LED GSM Bedienungsanleitung

Detection Systems
Detection Systems 7090i Montageanleitung

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Bedienungsanleitung

Siemens
Siemens FDM273 Bedienungsanleitung