If the user has FORGOTTEN the code, the panel has to be RESET to
FACTORYSETTINGS
ToresettoFactorySettings:
- Disconnect all power supply and the battery from the main
controlpanel.
- Presskey1and4simultaneously
- Reconnect the power supply while keeping 1and 4keys
pressed.
- The panel will reset to factory settings and MASTER CODE will
beresetto1234.
Pleaserefertosection1-3forFactorySettings.
In order to make it easier to operate the control panel, the key pad is fully
backlit. The key pad will illuminate if a button is pressed or any zone is
opened.ThelightSWITCHOFFautomaticallyafter2minutes.
As an additional safety feature, the control panel has one mains AC fuse
on the power supply card and TWO SAFETY FUSES on the main circuit
board.Intheeventofanoverloadinthepowersupply,sounderorauxiliary
supply circuits, a fuse will blow. This fuse must be replaced. You may
contactyournearestservicecentreforassistance.
- 10 -
ELECTRICAL
Quiescentcurrent:75mAtypical
Currentwithdialing&massageplay:160mA
Maximumsounder1currentoutput:1A
Maximumsounder2currentoutput:1A
SoundersaturationVoltage:<1Vat1A
Remotekeypads:Uptofive
Non-volatileMemory:ProgrammingandLog
Zoneresponsetime:<500ms
ZoneLoopsResistance:<5kohmforNORMALLYCLOSED
POWERSUPPLY
MainssupplyVoltage:220+10%-15%50Hz
TotalcurrentOutput:800mAat220VAC(FuseJA20mmOnMainCard)
Regulation:<9%
Ripple:<200mVRMS
Batteryvoltage:12VDC
Battery type:SMFRechargeable
Batteryrecharge voltage:13.8V+/-0.2VD
Fuse:250mA20mmACMainsonPSCard
ENVIRONMENTAL
OperatingTemperature:0ºCto45ºC
StorageTemperature:-20ºCto60ºC
Maximumhumidity:95%non-condensin
Environment:residential/commercial/lightIndustrial
PHYSICAL
Dimensions:236mmx226mmx80mm
MaxBatteryDimensions:150mmx110mmx64mm
- 11 -