Sentry 110 Bedienungsanleitung

Model 110 Operating Manual
Sentry Liquid Level Alarm
Page 1
Sentry
LIQUID LEVEL ALARM
MODEL 110
www.aquaticsentry.com
OPERATING MANUAL
WIRELESS

Page 2 Model 110 Operating Manual
Sentry Liquid Level Alarm
Rev 2.2 December 2020
Serial #DW110-01000 and up
TABLE OF CONTENTS
1. SAFETY PRECAUTIONS.................................................................. 3
2. APPLICATION ................................................................................... 3
2.1 HIGH Liquid Level Alarm
2.2 LOW Liquid Level Alarm
2.3 Optional Relay Output
3. INSTALLATION ................................................................................. 4
3.1 Mount Indoor Alarm Display
3.1.1 Installer Code and/or Radio Frequency
3.2 Mount the Outdoor Transmitter
3.2.1 Setting HIGH or LOW level function
3.2.2 Setting up Installer code or Radio Frequency
3.2.3 Install Batteries
3.3 Suspend the Probe
3.4 Test the alarm
3.4.1 HIGH Alarm
3.4.2 LOW Alarm
4. OPERATION and TROUBLESHOOTING........................................ 11
4.1 State Table and Troubleshooting - Indoor Alarm Display
4.2 Outdoor Enclosure Probe Assembly
4.3 Changing Installer Code or Radio Frequency
4.3.1 Program the Indoor Display
4.3.2 Program the outdoor transmitter
4.4 Wireless Transmission Timing
5. MAINTENANCE............................................................................... 14
5.1 Battery Change
6. SPECIFICATIONS ........................................................................... 15
6.1 Indoor Alarm Display
6.2 Outdoor Transmitter
6.3 IC and FCC 15 Approval
7. WARRANTY .................................................................................... 16
Printed in Canada

Model 110 Operating Manual
Sentry Liquid Level Alarm
Page 3
1. SAFETY PRECAUTIONS
The potential for electrical shock exists whenever water is present
near conductive electrical equipment. Check for sources of electricity
from other nearby devices before working on this equipment. There
is no possibility of serious shock from the energy levels used by this
alarm. The low voltage DC and transformer isolation provide safety
when handling or opening the enclosures or the probe. Best practice,
however, is to disconnect power when working on this equipment.
2. APPLICATION
The Sentry liquid level alarm continuously monitors a water level, rising
(high level) or falling (low level), that may cause an alarm condition.
Application examples are pump chambers, cisterns, holding tanks,
sumps, floor drains, irrigation channels or truck tanks. The alarm also
performs self-diagnostics, continuously testing that all components are
operating correctly. The battery powered outdoor probe communicates
with the indoor alarm display up to 90 m (300 feet) range. The indoor
alarm display will flash an LED and sound an audible alarm. Audio can
be muted with the pushbutton. When the alarm condition is corrected
the audio will reset.
• Green indicates power on and monitoring
• Red flashing and audio pulsing indicates an alarm condition
• Yellow or blue indicates an error in the wireless communication
or in the probe circuit
• Audio chirp warns of low batteries in the outdoor transmitter
See FIG 7 and section 4.1.
2.1 HIGH Liquid Level Alarm
HIGH LEVEL alarm condition occurs when the liquid level rises
to partially cover the pins on the bottom of the probe. An example
of rising water causing an alarm condition is a septic tank.

Page 4 Model 110 Operating Manual
Sentry Liquid Level Alarm
2.2 LOW Liquid Level Alarm
LOW LEVEL alarm condition occurs when the liquid level falls
below the middle of the pins of the probe. An example of falling
water level causing an alarm condition is a cistern that requires
filling.
2.3 Optional Relay Output
The relay output may be utilized to switch on remote alarms, input
to security systems, auto dialers, WiFi transmitters or control
applications. See FIG 5 and FIG 6. Set the relay operation to
Normally Open or Normally Closed with the jumper shown in
FIG 6.
3. INSTALLATION
3.1 Mount Indoor Alarm Display
Mount the Sentry indoor alarm display at a convenient viewing
location. Select an eye level location that is frequented, near a
120VAC receptacle. Power to the receptacle should be supplied
from a circuit separate from any pump that is being monitored
by this alarm. Install two supplied screws, 3” apart vertically
and projecting ¼” from the wall, to mount the display. Install
the AC adapter and plug into the alarm display. The LED will
be steady yellow with a continuous audio, indicating no wireless
communication. The supplied labels may be used to identify the
indoor alarm display’s function, ie HIGH LEVEL in the SUMP.
Radio transmission is improved by mounting away from sheet
metal or electrical wiring. Clear line of sight is the best situation.
3.1.1 Installer Code and/or Radio Frequency
If an installation requires multiple alarms, or if interference
with other radio devices occurs, change the installer
code and / or the frequency program. See section 4.3.
3.2 Mount the Outdoor Transmitter
Mount the Sentry outdoor transmitter near the water source to
be monitored. Fasten the weatherproof NEMA 6P enclosure to
a post or a riser pipe above grade using screws supplied. Radio

Model 110 Operating Manual
Sentry Liquid Level Alarm
Page 5
transmission is improved by mounting the transmitter higher off
grade. For access to disconnect probe wire see 4.2
3.2.1 Setting HIGH or LOW level function
The jumper position inside the outdoor transmitter
determines the HIGH LEVEL or LOW LEVEL function
to suit your application. See FIG 3. Using needle nosed
pliers, install the jumper, shorting the two terminals for a
HIGH LEVEL function. For a LOW LEVEL function the
jumper is installed on one terminal.
3.2.2 Setting up Installer code or Radio Frequency
If an installation requires multiple alarms, or if interference
with other radio devices occurs, change the installer
code and / or the frequency program. See section 4.3.
3.2.3 Install Batteries
Install the four AA cell batteries supplied.
3.3 Suspend the Probe
Suspend the probe at the depth the alarm is required. The
probe’s alarm point occurs when the pins are immersed 3/8” in
water
3.4 Test the alarm
3.4.1 HIGH Alarm
For a HIGH ALARM the LED will be green and on
steady with the probe out of the liquid. When the probe
is lowered into the liquid, the LED will turn flashing red
and the audible alarm will pulse. Silence the audible

Page 6 Model 110 Operating Manual
Sentry Liquid Level Alarm
alarm. Raise the probe out of the liquid to stop the red
LED flashing and to reset the audible alarm. Repeat this
sequence to prove operation. For any other conditions
see the State Table in section 4.1.
3.4.2 LOW Alarm
For a LOW ALARM the LED should be green and on
steady with the probe in the liquid. When the probe is
raised above the water, the LED will turn flashing red
and the audible alarm will pulse. Silence the audible
alarm. When the probe is lowered into the liquid the LED
will turn steady green indicating alarm is monitoring.
Repeat this sequence to prove the operation. For any
other conditions see the State Table in section 4.1.

Model 110 Operating Manual
Sentry Liquid Level Alarm
Page 7
FIG 1
Indoor Alarm Display Interior

Page 8 Model 110 Operating Manual
Sentry Liquid Level Alarm
FIG 2
Outdoor Transmitter Enclosure Cover Interior
FIG 3
Outdoor Transmitter Enclosure Interior Close-up

Model 110 Operating Manual
Sentry Liquid Level Alarm
Page 9
FIG 5
Optional Relay Output
FIG 4
Outdoor Transmitter Batteries Installed

Page 10 Model 110 Operating Manual
Sentry Liquid Level Alarm
FIG 6
Indoor Alarm Display
Setting relay to Normally Open or Normally Closed
Andere Handbücher für 110
1
Inhaltsverzeichnis
Andere Sentry Sicherheitssystem Handbücher
Beliebte Sicherheitssystem Handbücher anderer Marken

EDM
EDM Solution 6+6 Wireless-AE Bedienungsanleitung

Highway Safety Group
Highway Safety Group EA401 Bedienungsanleitung

Siren
Siren LED GSM Bedienungsanleitung

Detection Systems
Detection Systems 7090i Montageanleitung

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Bedienungsanleitung

Siemens
Siemens FDM273 Bedienungsanleitung