Model 1000 User Manual


Important Safety Instructions 2
Symbols Used in User Manual and on Oxygen System 2
Indications For Use 5
Contraindications 5
Safety Guidelines 6
Oxygen Therapy Safety 6
Operating Safety 7
Power Cartridge Safety 9
Introduction To Your ECLIPSE Oxygen System 10
Understanding the Controls and Front Panel 11
Description of the ECLIPSE 11
Control Panel Features 12
User Controls 13
Front Panel Icons 13
System Status Indicators 13
Recommended Operating Environments 15
The Proper Location 16
Operating Instructions 17
Before Operating 17
Powering Your ECLIPSE System 18
Operating Your ECLIPSE System 25
Alarm Conditions and Troubleshooting 30
Accessories 32
Cleaning, Care and Routine Maintenance 35
Technical Data 38
Summary of All Warnings and Cautions 40
Electromagnetic Compatibility 48
Disposal of Equipment and Accessories 49
Model 1000 User Manual
Contents

Important Safety Instructions are Shown
Under the Following Headings:
SeQual®Technologies Inc. (SeQual) recommends that this User Manual be given to
each patient receiving an ECLIPSETM Oxygen System. This User Manual describes all
the necessary information in order for a patient or caregiver to operate the ECLIPSE.
WARNING Important safety information for hazards that might cause
serious injury.
CAUTION Important information for preventing damage to the ECLIPSE
Oxygen System.
DO NOT Information to which you should pay special attention.
Important! Clarifying information, specific instructions, commentary, sidelights,
or interesting points.
Symbols Used in User Manual and on Oxygen System
Refer to this section for an explanation of the symbols and the warnings that
accompany them.
“Read Instructions”: This symbol, when used alone or in conjunction
with any of the following symbols, indicates the need to consult the
operating instructions provided with the product. A potential risk
exists if the operating instructions are not followed.
“Attention or Caution”: Consult accompanying documents. This
symbol indicates important information that requires the user to take
special precautions when certain conditions are present.
Important Safety Instructions
2|ECLIPSETM Model 1000 User Manual

“No Smoking or Naked Flames”: The use of oxygen therapy
requires that special care be taken to reduce the risk of fire. Materials
that burn in air, and even some materials that will not burn in air, are
easily ignited and burn rapidly in high concentrations of oxygen. For
safety concerns, all possible sources of ignition must be kept away
from the oxygen concentrator and preferably out of the room in which
it is being used. Smoking in the proximity of an operating oxygen
concentrator is dangerous, and can permanently damage the
device and void the warranty.
“Use No Oil or Grease”: Indicates important information about the
possibility of spontaneous and violent ignition that may occur if oil,
grease or other petroleum based substances come into contact with
oxygen under pressure.
“Drip Proof Equipment-IPX0”: The ECLIPSE enclosure does not
provide protection against the harmful effects of liquid ingress. (IPX0,
per IEC 60529)
“Drip Proof Equipment-IPX1”: The ECLIPSE AC and DC Power
Supplies provide protection against the harmful effects of liquid
ingress. (IPX1, per IEC 60529)
“IEC Icon for DC Power (Input)”
“Type B Equipment”: Equipment providing a particular degree of
protection against electric shock, particularly regarding:
- Allowable LEAKAGE CURRENT;
- Reliability of the protective earth connection.
“Amperes”
IPX
0
Model 1000 User Manual
ECLIPSETM Model 1000 User Manual |3
IPX
1

“Alternating Current”
“Audible Alarm”: An audible indicator is provided to announce a
reduction in oxygen concentration or when the power has been
interrupted or lost.
“ON/OFF”: Turns the unit ON and OFF but does not directly
disconnect the mains power.
“Increase Flow Setting”: Increases the flow setting in 0.5
increments each time the button is pushed.
“Decrease Flow Setting”: Decreases the flow setting in 0.5
increments each time the button is pushed.
“Flow Mode”: Activates either Continuous Mode or Pulse Flow
Mode Operation.
“External Power Present Indicator”: Indicates the presence of
external power to operate the concentrator.
“Power Cartridge Status”: Shows the amount of charge remaining in
the Power Cartridge.
“Power Cartridge Symbol”: The symbol on the Power Cartridge
pack.
“Oxygen Output”: The port in which the oxygen flows out and where
the tubing is attached.
Symbols (continued)
4|ECLIPSETM Model 1000 User Manual

THE ECLIPSE OXYGEN SYSTEM IS INDICATED FOR THE ADMINISTRATION OF
SUPPLEMENTAL OXYGEN. THE DEVICE IS NOT INTENDED FOR LIFE SUPPORT
NOR DOES IT PROVIDE ANY PATIENT MONITORING CAPABILITIES.
YOUR PHYSICIAN HAS PRESCRIBED A SPECIFIC OXYGEN FLOW RATE
SETTING TO MEET YOUR INDIVIDUAL NEEDS.
RECOMMENDED OXYGEN FLOW RATES SHOULD BE ADJUSTED ONLY
UNDER THE ADVICE OF A PHYSICIAN.
WARNING FEDERAL LAW RESTRICTS THIS DEVICE TO SALE BY OR ON THE
ORDER OF A PHYSICIAN.
WARNING THE ECLIPSE IS NOT INTENDED FOR LIFE SUPPORTING OR LIFE
SUSTAINING APPLICATIONS, NOR DOES IT PROVIDE ANY PATIENT
MONITORING CAPABILITIES.
WARNING IN CERTAIN CIRCUMSTANCES, THE USE OF NON-PRESCRIBED
OXYGEN CAN BE HAZARDOUS. THIS DEVICE SHOULD ONLY BE
USED WHEN PRESCRIBED BY A PHYSICIAN.
WARNING FOR ADULT USE ONLY. NOT QUALIFIED FOR USE ON PEDIATRIC
PATIENTS.
WARNING NOT FOR USE IN THE PRESENCE OF FLAMMABLE ANESTHETICS.
Contraindications
Indications for Use
Model 1000 User Manual
ECLIPSETM Model 1000 User Manual |5
WARNING AS WITH ANY ELECTRICALLY POWERED DEVICE, THE USER MAY
EXPERIENCE PERIODS OF NON-OPERATION AS THE RESULT OF
ELECTRICAL POWER INTERRUPTION, OR THE NEED TO HAVE THE
OXYGEN CONCENTRATOR SERVICED BY A TECHNICIAN. AN OXYGEN
CONCENTRATOR IS NOT APPROPRIATE FOR ANY PATIENT WHO
WOULD EXPERIENCE ADVERSE HEALTH CONSEQUENCES AS THE
RESULT OF SUCH TEMPORARY INTERRUPTION.

Safety Guidelines
6|ECLIPSETM Model 1000 User Manual
This section of the manual provides warnings and cautions that apply to hazards or
unsafe practices that could result in personal injury or property damage.
Oxygen Therapy Safety
“Read Instruction Manual”: DO NOT operate this oxygen system
without first reading and understanding this manual. If you are unable
to understand the warnings and instructions, contact your authorized
SeQual dealer/provider before attempting to use this oxygen system.
“Caution or Attention”: In certain circumstances, oxygen therapy can
be hazardous; therefore, it is advisable to seek medical advice before
using the oxygen system.
DO NOT deviate from prescribed flow rates. Adjust the flow only to your prescribed
flow rate, unless otherwise instructed by your physician.
WARNING “No Smoking or Naked Flames”: The use of oxygen therapy requires
that special care be taken to reduce the risk of fire. Oxygen enhances
the combustion of flammable material. For safety concerns, all possible
sources of ignition must be kept away from the oxygen system and
preferably out of the room in which it is being used. Smoking in the
proximity of an operating oxygen concentrator is dangerous, and
can permanently damage the device and void the warranty.
WARNING “Use No Oil or Grease”: A spontaneous and violent ignition may
occur if oil, grease or other petroleum substances come into contact
with oxygen under pressure. Keep these substances away from the
oxygen system, tubing and connections and any other oxygen source.
DO NOT use any petroleum based or other lubricants.

Operating Safety
■Keep oxygen system and cord away from hot surfaces.
■DO NOT use the oxygen system if it has a damaged cord or plug; contact your
dealer/provider.
■Your oxygen system should be located in a well-ventilated area to allow for
adequate air intake and to avoid the intake of airborne pollutants and fumes.
■ONLY use this device with accessories designed or recommended by SeQual
Technologies Inc.
■If your oxygen system has been dropped, damaged or exposed to water, contact
your dealer/provider for examination or repair.
■DO NOT drop or insert any object into any opening.
■DO NOT block the air inlet or the exhaust vent of the ECLIPSE when it is on
a soft surface, such as a bed or couch or car seat.
■DO NOT cover unit with a blanket, towel, quilt, etc.
■DO NOT overfill the humidifier, if used. Fill with water only to the level shown
by the manufacturer.
■When using ECLIPSE in a vehicle, make sure it is properly secured or restrained.
Model 1000 User Manual
ECLIPSETM Model 1000 User Manual |7

Operating Safety (continued)
WARNING DO NOT remove the cover, no serviceable parts inside. Qualified
service personnel should only remove the cover.
WARNING DO NOT operate device or accessories on wet surfaces or in standing
water and DO NOT submerse or expose to water. The ECLIPSE
enclosure does not provide protection against the harmful effects of
liquid ingress. Electrical shock or damage to the unit may result.
WARNING Protect electrical cords from sharp edges. Electrical shock and serious
physical injury may result.
WARNING Use only the SeQual AC Power Supply and DC Power Supply supplied
with your ECLIPSE Oxygen System. Use of a non-SeQual Power
Supply may be hazardous, cause damage to your oxygen system
and will void the warranty.
CAUTION Availability of an alternate source of oxygen is recommended in
case of power outage or mechanical failure.
CAUTION DO NOT expose unit to temperature outside of specified operating
or storage temperatures as this may damage the unit.
CAUTION Locate oxygen tubing and Power Supply cords to prevent tripping
hazards.
CAUTION DO NOT place ECLIPSE in a small, enclosed space, such as a
bathroom or closet, with cannula leading out of the enclosed space.
Safety Guidelines (continued)
8|ECLIPSETM Model 1000 User Manual
Inhaltsverzeichnis
Andere SeQual Sauerstoffgeräte Handbücher