Sermatec LV3584 Bedienungsanleitung

1/16
LFP Storage System
LV3584 User Manual
Document No.:
Version:V1.0

2/16
Contents
LV3584 USER MANUAL ...............................................................................................................................1
1. SCOPE AND SIGN ....................................................................................................................................3
2. PRODUCT COMPONENTS ...................................................................................................................... 7
2.1 PRODUCT MAIN COMPONENTS ..........................................................................................................7
2.2 BATTERY SYSTEM PORT ..................................................................................................................... 7
2.3 SYSTEM DIAGRAM ................................................................................................................................8
2.4 ANNOUNCEMENTS OF PARALLEL CONNECTION BEFORE START-UP .......................................10
2.5 BATTERY SYSTEM PORT ................................................................................................................... 11
2.6 PACKAGE ............................................................................................................................................. 12
3. PRODUCT ELECTRICAL CHARACTER ............................................................................................... 13
3.1 MODULE SPECIFICATION .................................................................................................................. 13
4. BATTERY MANAGEMENT SYSTEM (BMS) FUNCTION ......................................................................14
5. PRODUCT EXTERIOR REQUIREMENT ............................................................................................... 14
6. DATA STORAGE REQUIREMENT .........................................................................................................14
7. PACKING, TRANSPORTATION, STORAGE REQUIREMENTS ...........................................................14
7.1 PRODUCT PACKAGE PACKING REQUIREMENTS .......................................................................... 14
7.2 PRODUCT TRANSPORTATION REQUIREMENTS ............................................................................ 14
7.3 PRODUCT STORAGE REQUIREMENT .............................................................................................. 14
8. REGULAR MAINTENANCE............................................................................................................................... 15
8.1 SOC CHECK....................................................................................................................................................... 15
8.2 CABLE CHECK.................................................................................................................................................. 15
8.3 BALANCE............................................................................................................................................................15
8.4 OUTPUT RELAY CHECK................................................................................................................................. 15
8.5 HISTORY CHECK.............................................................................................................................................. 15
8.6 MAINTENANCE..................................................................................................................................................15

3/16
1. Scope and Sign
This User Manual is to describe the technical indexes of LV3584 Battery Module produced by
Shanghai Sermatec Energy & Technology Co.,Ltd.And would be used as the basis of product
inspection by Sermatec Quality Department and Client.
This manual includes important description given below: The installation and usage of LV3584
storage product must follow this manual. The design of the product and the tests are based on the
global safety requirements. But same for all the electricals, you must follow some prevention
strategies during installation and operation. To decrease the risk of human injury and make sure that
the product is installed and operated safely, you must read and follow all the descriptions,
announcements and warnings carefully.
Signs
Danger
Fatal Voltage!
Battery module would generate DC voltage, and would cause fatal
voltage and electric shock.
Only trained person can do the installation of the battery module.
Warning
Damaged battery system may lead to risk of human injury.
Don’t draw the connector when the system is working!
Cut off on several power source, and make sure that there is no
voltage left.
Alarm
Decrease the possibility of battery module system error or risk on
life-cycle.
Read
Sings
Please firstly read the User Manual and Datasheet before starting
using the battery!

4/16
Sign
Danger! Careful!
Sign l
Be Careful of Electric Shock!
Sign
Don’t put the system beside inflammables.
Sign
Don’t connect +/- reversely.
Sign
Don’t put the system beside fire.
Sign
Isolate the system from children and pets.
Sign
Recycle Sign

5/16
Sign
Waste Electrical and Elecctronic Equipment (WEEE) Command
(2012/19/EU)
Sign
EMC Certificate Sign
Sign
TÜV SÜD Safety Certificate Sign
Danger: Battery provides electricity. When battery is short-circuit or wrongly installed,
may lead to danger of burn or fire.
Danger: Fatal voltage exists in battery port and cables. Touch cables or ports could lead
to serious human injury or death.
Warning: Please don’t open or change the appearance of the battery module;
Warning: When operate on the batteries, please wear proper Personal Protective
Equipment (PPE), e.g. rubber gloves, rubber boots, goggles.
Warning: LV3584 system working temperature range: 0℃~50℃; Proper temperature: 18℃~ 28℃. If it
exceeds the range, the battery life-cycle might be decreased or even cause battery system over/low
temperature warning or protection. And may influence warranty.
Warning: On the battery installation, installers shall follow the local installation standards.
Attention: Improper setting or service may permanently destroy the battery.
Attention: Wrong inverter parameters may lead to battery early aging.
Alarm
1)During installation or operation, please carefully read the user manual (in the
attachment), this is very important and necessary. If you don’t follow the instruction or
warnings in this document, it could lead to electric shock, serious damage, or death, or destroy the

6/16
battery and impossible to control the battery.
2)During Long period of storage, it is necessary to charge every half a year, SOC should be higher
than 90%;
3)Battery need to be charged before 12 hours after fully charged.
4)Cables need to be sufficiently insulated.
5)During maintenance, all the battery ports must be disconnected.
6)If you find any error, please directly contact manufacturer in 24 hours.
7Please don’t use cleanse to wash the battery.
8)Please don’t expose the battery to inflammables or pungent chemicals or steam;
9)Please don’t paint any part of the battery, including inside or outside components.
10)Please don’t directly connect battery and PV panels.
11)Except authorized Sermatec staffs, don’t open, repair or disassembly batteries. Our company
doesn’t take responsibility for any results due to disobeying safety operation or design, production
and device safety standards.
12)Direct or indirect damage due to above items, is not included in Sermatec warranty.
13)It is not allowed to insert foreign matter to any part of the battery.
1.2Before connection
1)Please firstly check the product and pack list after opening the case. If there is any
damage or missing, please contact local dealer.
2)Before installation, please make sure that grid power is cut off, and make sure that the battery is at
‘Off’ condition.
3)Connection must be correct, don’t connect battery +/- reversely, and make sure that the battery is
not short-circuited.
4)Don’t connect battery directly with AC power.
5)Battery inner BMS is 51.2VDC, please don’t connect the battery in series.
6)The battery system shall be grounded sufficiently, and the resistance shall be smaller than 100mΩ.
7)Make sure that the battery system electrical parameters is compatible to related devices.
8)Make the battery far from water and fire.
1.3Usage
1)If you need to move or repair battery system, you must cut off the power, and totally shut
down the battery.
2)Don’t connect the battery with different types of batteries
3)Don’t connect the battery with malfunctioning or incompatible inverters.
4)Don’t disassembly the battery (When the QC label is teared or destroyed).
5)When fire occurs, please use dry powder extinguisher, don’t use liquid extinguisher.

7/16
2. Product Components
2.1Product main components
Component
Specification
Figure
Battery Box
70Ah 1P16S
Low Voltage BMS
Maximum Current 125A
Pedestal
Width 352mm Depth 570mm Height 60mm
Power Cables
Orange and Black 1xAWG3,Surlok
Connector
Communication
Cable
CAN, RS485 communication cable
Battery Output
Surlok Port
2.2 Battery System Port
Power Output
Communication
Power Switch
SOC Display,
Status Indicator,
WiFi indicator,
Alarm Indicator

8/16
2.3 System Diagram
Model Type
LV3584
Battery Cell
LFP
Battery Energy(kWh)
7.16
10.75
14.33
17.92
21.5
25.08
28.67
Battery Voltage(Vdc)
51.2
Battery Capacity(AH)
140
210
280
350
420
490
560
Module Number(pcs)
2
3
4
5
6
7
8
Module Energy(kWh)
3.584
Module Voltage(Vdc)
51.2
Module Capacity(AH)
70
Cell Number(pcs)
16
Charging Voltage(Vdc)
57
Nominal Charging
Current(A)
28
42
56
70
84
98
112
Suggested Charging
Current(A)
70
105
125
Charging Current(A,
Max.@15S)
130

9/16
Cut-off Discharging
Voltage(Vdc)
47.4
Nominal Discharging
Current(A)
28
42
56
70
84
98
112
Suggested Discharging
Current(A)
70
105
125
Maximum Discharging
Current(A)
125
Efficiency(%, ≤0.5C-rate)
96
Depth of Discharge%)
90
Dimension(W*D*H,mm)
570*352*
537
570*352*
693
570*352*
849
570*352*
1005
570*352*
1161
570*352*
1317
570*352*
1473
Communication
RS485\CAN
Protection Level
IP55
Weight (kg)
Life Cycle(Years)
15+
Working Temperature(℃)
0~50
Storage Temperature(℃)
-20~60
Altitude(M)
<2,000
Product Certificate
IEC62619 CE
Transport Certificate
UN38.3
1)Controller Dimension
(W*D*H, mm)
2)Module Dimension
(W*D*H, mm)
3)Pedestal Dimension
(W*D*H, mm)
570*352*165
570*352*156
570*352*60

10 /16
2.4 Announcements of parallel connection before start-up
1. Install and pile the batteries correctly, and then turn the switch to ‘ON’ position, start up the
batteries. When the batteries are installed wrongly, it would lead to startup error. After starting up
the system normally, the batteries would distribute the address automatically. The main control
box at the top would judge through the data sent from the below batteries.If the data sent from the
batteries are judged to be normal, the batteries would be started up successfully, otherwise
startup would fail.
2. Shut down. When the battery is not charged or discharged, then you can shut down the battery.
The switch can be used to cut-off the circuit when the battery is powering the loads. But to protect
outer devices, we suggest to firstly shutdown the loads and stop charging/discharging and then
turn the switch to ‘Off’, and make sure that the indicators are OFF, so that the battery is shut
down.
Inhaltsverzeichnis
Andere Sermatec Lagerung Handbücher
Beliebte Lagerung Handbücher anderer Marken

Spectra Logic
Spectra Logic T-Series Spectra T50e Bedienungsanleitung

Panasonic
Panasonic LKM-F931-1 Bedienungsanleitung

Tabernus
Tabernus Enterprise Erase E2400 Bedienungsanleitung

Rocstor
Rocstor COMMANDER 3F series Bedienungsanleitung

HP
HP P9000 Bedienungsanleitung

Western Digital
Western Digital Ultrastar Data60 Bedienungsanleitung