Function Instruction:
7 wired and 99 wireless defense zones;
LCD screen with time clock display;
Voice prompt for all operations;
3 groups of timely arm and disarm;
Can store 6 phone numbers: when alarming, system will make
alarm call to these numbers automatically;
Can store 3 SMS numbers: when alarming, system will send
alarming SMS automatically;
10-second automatic message recording;
Built-in artificial intelligent digital voice announcer;
Built-in artificial intelligent English message;
Users can make calls by using keypad on alarm panel, just like a
telephone;
One-key-control function: Out Arm, Home Arm, Remote Arm;
SOS, fire, gas, door, hall, window, balcony, and boundary places
alarm;
Real-time, delay, 24 hours, bypass defense zones programming
function;
Wireless coding: easy to add additional wireless accessories;
Remote control Arm, Disarm, Monitor, and Intercom by phone;
SMS alert for power failure or recovery;
Built-in AAA NI-HI rechargeable battery: make alarm when power
off;
Comply with CCC safety standard and GB12663-2001 national
standard.
Alarm Host Diagram
In order to make the main unit get the wireless signal well for all wireless
accessories, please put the alarm host at the central place of your defense area.
Makesureit’saway from largemetal objects and household appliances which
may cause high frequency interference, as well as barriers such as reinforced
concrete wall or fire door, etc.

3
Alarm Panel front schematic diagram:
Alarm Panel back schematic diagram:
Wired terminal block:
Z 1
Z 2
SP+
+-
SP
LB+
LB
GN D
GND
Z 3
Z 4
Z 5
Z 6
GND
Z 7

4
1 LB- Negative of two-way speaker (black cable)
2 LB+ Positive of two-way speaker (red cable)
3 GND Ground
4 Z1 Wired sensor 1: support NO and NC
5 GND Ground
6 Zone 2 Wired sensor 2: support NO and NC
7 Zone 3 Wired sensor 3: support NO and NC
8 GND Ground
9 Zone 4 Wired sensor 4: support NO and NC
10 Zone 5 Wired sensor 5: support NO and NC
11 GND Ground
12 Zone 6 Wired sensor 6: support NO and NC
13 Zone 7 Wired sensor 7: support NO and NC
14 SP- Negative of Siren (black cable)
15 SP+ Positive of Siren (red cable)
Note:
1. “LB-”and “LB+”are to connect external speaker. If you think the
internal speaker is not loud enough, please contact us for professional
speakers.
2. Connect one cable of the wired sensor to GND and the other to
“Z1/Z2/Z3.../Z7”.
3. Please pay attention to the siren connection. Do not mix the two cables
together when connecting. Otherwise,it will damage the transistor in the
main panel.

5
LCD display:
Function Settings
1. Initialization
Please insert SIM card and plug in power adaptor, and then power on the
system, all the LED lights will be on for 2 seconds and you will hear a
long beep; the system comes into initialization. After the time clock
displays on the LCD screen, the [SGM] starts flashing and the main unit
starts to detect the GSM network until a long beep. Then the [SGM]
indicator goes out indicating the system comes into disarm status.
Finally, turn on the backup battery switch.
2. Enter Settings
In the state of disarm, input 4-digit password by the keypad on the main
unit and press [#] button to confirm. You will hear a voice prompt: please
enter instruction. At the same time, [SET] indicator is on without flashing
and [0000] displays on the screen, indicating the system enters setting
status. You can perform different settings repeatedly as long as the system
keeps in setting status. The system will exit setting mode and return to
disarmstatusif you don’t pressany keypadbutton for 40 seconds.

6
Note:In setting status,press can delete the numbers input.
The system default password is [8888].
Operating method: [XXXX] [#]
Xindicates the new 4-digit password.
LCD display:
3. Exit Settings
Press [*] and [#] buttons, the main unit emits a long beep and exits
settings. The [SET] indicator goes out and the system returns to disarm
state.
Operating method: 【*】 【#】]
4. Factory Reset
In disarm status, use keypad to input [95175308246] and press [#] to
confirm, all the LED indicators will be on for 2 seconds and you will
hear a long beep. The main unit gets all its settings cleared and restores
to its factory settings successfully.
Operating method: [95175308246] + [#]
5. Coding of Remote Controller
The remote controller has to be code to the alarm host in order to
perform normally.
In setup state, use keypad to input [20], input the remote controller
number [1~8], and then press [#] to confirm. The main unit emits a long
beep and you will hear “remotecontrol coding”. The [ ] indicator is
on without flashing; press any button on the wireless remote controller,
the main unit makes a long beep and you will hear “coding completed”,
[ ] indicator goes out, indicating the remote controller succeeds in
coding.
Operating method: [20] [A] [#]
Aindicates:1~8 remote controllers number.

7
You can add maximum 8 remote controllers.
LCD display:
`
6. Delete Remote Controller
Theremotecontroller can’t control the main unit after it’sdeleted.
In setup state, use keypad to input [21], then input the remote controller
number [1-8], and then press [#] to confirm. The main unit emits a long
beep and the [Signal] indicator flickers once. You will hear a voice
prompt “delete completed”.
Operating method: [21] [A] [#]
Aindicates:1~8 remote controllers number.
Coding of Defense Zone
Wireless detectors have to be coded to the main unit in order to trigger it
alarm.
In setup state, use keypad to input [23], input the defense zone number
you want to code [01~99], and then input [#] to confirm. The main unit
emits a long beep and the corresponding defense zone is displayed on the
screen. You will hear a voice prompt “detector coding”. Then trigger a
wireless detector to emit a wireless signal; after receiving the signal, the
main unit makes a long beep, and you will hear “coding completed”, the
[ ] indicator goes out at the same time.
Operating method: [23] [XX] [#]
XX indicates: 01 ~99 defense zones number
LCD display:
8. Delete Defense Zone
The wireless detector can’t control the main unit after it’sdeleted.
In setup state, use keypad to input [24], then input the defense zone
number you want to delete [01~99], and then input [#] to confirm. The

8
main unit emits a long beep and the defense zone indicator flickers once.
You will hear a voice prompt “delete completed”.
Operating method: [24] [XX] [#]
XX indicates: 01 ~99 defense zones number
9. Change Password
1) Change Operation Password
Operation password is the password used to disarm or remote control.
In setup status, use keypad to input [30], then input the 4-digit new
password, and then press [#] to confirm. The main unit will make a long
beep and you will hear a voice prompt “settingcompleted”.
Operating method: [30] [XXXX] [#]
XXXX indicates: the new 4-digit password
For example: change the system password to 1012
Operating method: [30] [1012] [#]
LCD display:
2 ) Change Program Password
Program password is the password you should input in order to setup
the system.
In setup status, use keypad to input [31], then input the 4-digit new
password, and then press [#] to confirm. The main unit will make a long
beep and you will hear a voice prompt “settingcompleted”.
Operating method: [31] [XXXX] [#]
XXXX indicates: the new 4-digit password
For example: change the system password to 2846
Operating method: [31] [2846] [#]
LCD display:
Note:the operation password and the programming password can not be set
as the same number.

9
10. Clock Setting
In setup status, use keypad to input [32], then input the last 2 digits [AA]
of the present year, the two digits [BB] of the month, the two digits [CC]
of the date, the two digits [DD] of the hour (24-hour system), the two
digits [EE] of the minute, the two digits [FF] of the second, and finally
enter [#] to confirm. You will hear a long beep and a voice prompt
“settingcompleted”.
Operating method: [32] [AA] [BB] [CC] [DD] [EE] [FF] [#]
AA indicates: the last 2 digits of the present year
BB indicates: the 2 digits of the present month
CC indicates: the 2 digits of the present date
DD indicates: the 2 digits of the present hour
EE indicates: the 2 digits of the present minute
FF indicates: the 2 digits of the present second
For example: set the time as 15:35:40, Oct. 1st, 2009
Operating method: [32] [09] [10] [01] [15] [35] [40] [#]
11. Timing Settings
1 ) Timely Arm
In setup status, use keypad to input [33~35], then input the hour [AA] and
minute [BB] of the time you want to set to arm, and finally input [#] to
confirm. You will hear a long beep and a voice prompt “setting
completed”.
Operating method: [XX] [AA] [BB] [#]
XX indicates: the address code 33, 34, 35 of the timely arming
AA indicates: the hour of the setting time
BB indicates: the minute of the setting time
For example: set the arm time as 45’10pm
Operating method: [33] [22] [45] [#]
LCD display:

10
2 ) Timely Disarm
In setup status, use keypad to input [36~38], then input the hour [AA] and
minute [BB] of the time you want to set to disarm, and finally input [#] to
confirm. You will hear a long beep and a voice prompt “setting
completed”.
Operating method: [XX] [AA] [BB] [#]
XX indicates: the address code 36, 37, 38 of the timely disarming
AA indicates: the hour of the setting time
BB indicates: the minute of the setting time
For example: set the arm time as 55’7pm
Operating method: [33] [22] [45] [#]
LCD display:
3) Timing Control
In setup status, use keypad to input [39], then input the number indicating
turning on timely arm/ disarm [1/0], and then input [#] to confirm. You
will hear a long beep and a voice prompt “setting completed”. The factory
default is off.
Operating method: [39] [0/1] [#]
0: turn off the function of timely arm/ disarm
1: turn on the function of timely arm/ disarm
For example: turn on the function of timely arm/ disarm
Operating method: [39] [1] [#]
12. Time setting for OutArm Delay (Default: 60sec)
In setup state, input the command: 44+(XX) + #
XX indicates: the delay time of out arm: XX=01-99:1 sec to 99 sec
Note: The setting is effective only with the keypad operation.
The operation by remote controller or SMS is immediate arm without
delay.
Beliebte Sicherheitssystem Handbücher anderer Marken

EDM
EDM Solution 6+6 Wireless-AE Bedienungsanleitung

Highway Safety Group
Highway Safety Group EA401 Bedienungsanleitung

Siren
Siren LED GSM Bedienungsanleitung

Detection Systems
Detection Systems 7090i Montageanleitung

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Bedienungsanleitung

Siemens
Siemens FDM273 Bedienungsanleitung