SHARPY 20R Bedienungsanleitung

1Please read the manual carefully before use. 350W beam pattern
lamp three in one shaking head lamp
an instruction manual
(color display, touch operation)


catalogue
Chapter 1 precautions and installation.......................................... 1
1. Maintenance............................................. 1
2. Declaration......................................... 1
3. Precautions for products.......................................... 1
4. Product introduction........................................ 1
5. Signal line connection (DMX)................................................... 2
6. Installation of lamps........................................ 2
Chapter 2 panel operation........................................ 3
1. General......................................... 3
2. Operation......................................... 3
1. Use visual touch or encoder to operate lamps........................................ 3
2. Parameter value input......................................... 3
3. Set Boolean parameters........................................ 4
4. Sub page (parameter).................................................................... 4
3. Function operation and parameter setting........................................ 4
1. Set DMX address code.......................................... 4
2. Set the working mode of lamps.......................................... 5
3. Setting panel display settings.......................................... 6
4. Test lamps.......................................... 6
5. Setting the working parameters of lamps.......................................... 7
6. Check the current status of lamps.......................................... 7
Chapter 3 channel description........................................ 8
1. Channel table.......................................... 8
Chapter 4 common faults and precautions for use........................................ 11
1. Common fault handling........................................ 11
2. Precautions for use........................................ 11

Chapter 1 precautions and installation
1. Maintenance1. Maintenance
The lamp shall be kept dry to avoid working in humid environment.
Intermittent use will effectively prolong the service life of the lamp.
In order to obtain good ventilation effect and lighting effect, pay attention to
regularly cleaning the fan, fan net and lens.
Do not wipe the lamp shell with alcohol or other organic solvents to avoid damage.
2. Declaration2. Declaration
This product has good performance and complete packaging when leaving the
factory.All users shall strictly abide by the warnings and operating instructions
stated above. Any damage caused by misuse is not within the warranty of the company,
and the faults and problems caused by ignoring the operating manual are not within
the scope of the distributor's responsibility.
This manual is subject to technical changes without notice.
3. Product precautions3. Product precautions
In order to ensure the service life of the product, the product shall
not be placed in a wet or leaking place, nor shall it work in an
environment with a temperature of more than 60 ℃
Do not place the product in a place easy to loosen or shake.
In order to avoid the danger of electric shock, please ask a professional for
maintenance of this product.
When the bulb is used, the change of power supply voltage shall not exceed ±10%.
If the voltage is too high, the service life of the bulb will be shortened. If
the voltage is too low, the light color of the bulb will be affected.
After power failure, the lamp shall be fully cooled after 20 minutes before it
can be powered on again.
To ensure the normal use of this product, please read this instruction carefully.
4. Product introduction4. Product introduction
Light source power: 380W;
Rated power: 500W (high efficiency and reliable switching power supply);
Power supply: high efficiency and reliable switching power supply;
Color disk: one color disk, each color disk is composed of 14 color chips + white
light;
Pattern disc: 14 pattern effects, 9 rotating pattern effects;

Effect wheel: a rotatable 8 prism and a 6-sided array of mirrors;
Dimming: 0-100% electronic dimming;
Large adjustable range of beam angle;
Stroboscopic: support mechanical stroboscopic and adjustable speed stroboscopic
effects, and support stroboscopic macro functions;
Lens group optical system, electric focusing, beam angle 3.8 °- 45 °, linearly
adjustable;
Photoelectric reset system is adopted, which can automatically retrieve and reset
in case of accidental misoperation;
Horizontal 540 °, resolution 8bit / 16bit;
Vertical 270 °, resolution 8bit / 16bit;
Overheating protection;
Control mode: DMX512 / master-slave / automatic;
Protection grade: IP20;
5. Signal line connection (DMX)5. Signal line connection (DMX))
Use RS-485 cables that meet the specifications: shielded, 120ohm characteristic
impedance, 22-24 AWG, low capacitive reactance. Do not use microphone cables or
cables with different specified characteristics. The terminals must be connected
with 3 or 5-pin XLR male / female connectors. A 120ohm impedance matching resistance
(minimum 1 / 4 W) must be inserted between terminals 2 and 3 of the terminal plug.
Important: wires shall not contact each other or metal shell.
Figure 1 DMX signal line connection diagram

6. Lamp installation6. Lamp installation
Lamps can be placed horizontally, hung obliquely and upside down. Pay attention
to the installation method when hanging obliquely and upside down
As shown in Figure 2, before positioning the lamp, ensure the stability of the
installation site. During reverse hanging installation, ensure that the lamp does
not fall on the support frame. It is necessary to use safety rope to pass through
the support frame and lamp handle for auxiliary hanging to ensure safety and prevent
the lamp from falling and sliding.
During the installation and commissioning of lamps, pedestrians are not allowed
to pass below. Regularly check whether the safety rope is worn and whether the hook
screw is loose.
If the lamp falls due to unstable hanging and installation, our company will not
bear any responsibility.
chart2 Schematic diagram of upside down lamps

Chapter 2 panel operation
1. General1. General
The schematic diagram of the lamp panel is shown in Figure 3 (this diagram is a 4-key key).
The TFT display screen on the left supports touch operation, and the 4-key or 5-key keys or encoder
knob on the right can directly operate the lamp or set system parameters.
The display and operation are similar to "Android operating system". If the product you select
supports touch operation, you can click the corresponding item with your fingertips or blunt objects.
Note: do not use sharp or sharp objects to click on the display screen to prevent damage.
chart3 Display panel diagram
2. Operation2. Operation
1. Use visual touch or encoder to operate lamps1. Use visual touch or encoder to
operate lamps
The left area is TFT display area and touch area. Click the panel content with
your finger or blunt hardware to complete parameter setting or view status.
The right area is the "rotary encoder" as auxiliary input. If you do not use the
touch function of TFT, you can rotate the encoder to select the item to be set
or viewed, then press the encoder to confirm the selection, rotate the encoder
to set the parameter value again, and finally press the encoder protection
setting to complete the operation.
2. Parameter value input2. Parameter value input
When the selected parameter item needs to enter a value, the window as shown
in Figure 4 will open:

chart4 Value setting page
Set value:You can directly pull the slider to quickly set the required value,
or you can click the "up" or "down" button on the right to accurately set the
required value Or rotate the "rotary encoder" on the right to set it;
Application value:When the data is set through the "up" or "down" buttons, then
press the button in the lower left corner“apply”Application key, the value is
sent to the lamp immediately, but the value is not saved;
Save value:At any time, click the "OK" button in the lower right corner, that
is, save the current value to the internal memory, and apply the saved value
to the lamp next time.
3. Set Boolean parameters3. Set Boolean parameters
When the set parameter is Boolean (such as on or off)When pressing, you can directly
click the corresponding item to switch the parameter value, and the modified
parameters will be saved to the internal memory. Press the parameter option on
the right, and the corresponding option will become gray. When you release your
hand, the corresponding parameters will be changed and saved. If the pressed
parameter option is not the parameter you want to change, you can move your finger
to other parts of the screen, and the corresponding parameters will not be
changedChange.
Important Boolean parameters will be set through the confirmation window, as shown
in Figure 5 below:
chart5 OK input window
4. Sub page (parameter)4. Sub page (parameter)
Click the main menu to enter the sub menu page, as shown in Figure 6. There are
6 sub pages, including different types of parameters or states, as follows:
Address: set the DMX address of the lamp;
Workmode: set the working mode and master / slave mode of the lamp;
Display: set the parameters of the display interface, such as language,
screensaver mode, etc;

Test: it is mainly used to test lamps and simulate the values of corresponding
DMX channels. Refer to the channel menu for the corresponding functions of
channel values;
Advance: set the operating parameters of lamps;
Status: view the current status of lamps.
chart6 Page graph
3. Function operation and parameter setting3. Function operation and
parameter setting
Enter the setting interface, as shown in Figure 6:
In the main interface, you can touch six buttons to enter the corresponding
parameter setting interface.
In the parameter setting interface, you can press the blue option on the left to
quickly switch to other setting interfaces.
1. Set DMX1. Set DMXAddress code
Click and select "address (addr)" to enter the DMX address code setting page.
The address code value range is 1 ~ 512, and the address code cannot be greater than
(512 channel number), otherwise the lamp will not be controlled. The specific setting
operations are as follows:
Enter the DMX setting interface, as shown in Figure 7, click the white area on
the right to pop up the parameter setting window as shown in Figure 4. You can directly
pull the red square of the progress bar to quickly set the DMX address code value,
or press the "up" or "down" key to accurately set the desired DMX address code, and
then press the Enter key to save the data to complete the address code setting
operation.

chart7 Address code setting page
2. Set the lamp working mode2. Set the lamp working mode
The operation mode, control light gun and channel mode of the lamp can be set
through the page shown in Figure 8. The lamp supports three operation modes (DMX
mode, self-propelled mode and voice control mode). Please refer to the previous
section for detailed parameter value settings. The specific parameters are described
as follows:
DMX mode:In this mode, the lamp receives data from the console and operates
according to the data of the console (common mode);
Self propelled mode:In this mode, the lamp does not receive console data and runs
by itself with an internal fixed program;
Voice control mode:In this mode, the lamp does not receive console data. When
there is a strong sound in the environment, the lamp will run a scene, otherwise
it will maintain the last scene.
Master slave selection:"Master-slave selection" only takes effect when the lamp
works in "self-propelled mode" or "voice control mode". When this option is
turned off, the internal program data of lamp operation will not passDMXThe
data line is sent to other lamps. When it is turned on, the data will be sent
to other lamps in real time, and other lamps (slave) of the same type will run
synchronously with the lamp (host).
Lamp switch:Through this setting, the opening and closing of the lamp can be
controlled. Note that the lamp can not be opened and closed too frequently, which
will reduce the service life of the lamp. The time interval between turning on
and off the lamp has been limited to30Seconds, that is, after the light bulb
changes state30Within seconds, multiple on and off operations are ignored, and
only the last operation is retained.
Channel mode:The lamp supports two channel modes, "simplified" channel saves
several channels for setting motor speed, and each operation mode channel saves
energyDMXFor channel utilization, the "extended" channel is more than the
"thin" channel, as described above. Please refer toThe first3chapterChannel
table description for.
Inhaltsverzeichnis
Beliebte DJ-Equipment Handbücher anderer Marken

thomann
thomann Stairville DJ Lase 40-G MK-III Bedienungsanleitung

Eagletone
Eagletone 6 Eyes Flower Bedienungsanleitung

EuroLite
EuroLite FLD-1508 Bedienungsanleitung

Technical Pro
Technical Pro LG8xSEA Bedienungsanleitung

JB Systems
JB Systems Lounge Laser DMX Bedienungsanleitung

Lightmaxx
Lightmaxx Vega Halo 90 Bedienungsanleitung

Elation
Elation FUZE WASH Z350 Bedienungsanleitung

Maverick
Maverick MK3 WASH Bedienungsanleitung

Infinity
Infinity TF-260C7 Fresnel Bedienungsanleitung

Chauvet
Chauvet EVE E-50Z Bedienungsanleitung

Eliminator Lighting
Eliminator Lighting E 138 Bedienungsanleitung

EuroLite
EuroLite Mini Multicolor LED Flashing Light SC Bedienungsanleitung





