Sierra Eagle 12 VX Handbuch

2018 USER MANUAL/Installation Instructions
EGL-12VX Oil-less Compressor
1953 W. Gulf To Lake Hwy, Lecanto, FL 34461
Toll Free: 800-240-5677 FAX: 352-513-4801
Email Address:
SierraDentalProducts@Outlook.com
Website:
www.Dentalvacuums.com

TABLE OF CONTENTS
Cover
Congratulations
Customer support
Warranty Policy
Safety
Safety Continued
System Layout
System Layout Cont.
Specifications
Installation
Installation Cont.
Start-up Procedure
Preventative Maintenance
Maintenance Cont.
Troubleshooting
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
On the Purchase of your Eagle 12 VX oil-less dental compressor. Our Eagle 12 VX
oil-less dental compressors provide clean dry air to each chair
flawlessly, requiring less maintenance than traditional compressors. Now that’s
peace of mind you can stand behind! We are certain you will love your new product!
If you are not satisfied 100% with this products please reach out and let us know,
we are successful because of your FEEDBACK!
800-240-5677
Email: sierradentalpr[email protected]om
2

CUSTOMER SUPPORT
“We are happy to help you with any questions or concerns you
may have about your Eagle VX dental compressor”
Contact Us 24/7 We are here for you!
Sierra Dental Products LLC
1953 W. Gulf to Lake Hwy
Lecanto, FL 34461
SierraDentalProduc[email protected]
DentalVacuums.com
Look for us… on social media!
3
NAME ROLE NUMBER
Karen Bennett Owner (352) 527-1975
Chuck Bennett Owner/Engineer (352) 527-1975
David Rolerad Owner/Quality control (603) 493-3635
Matthew Ball Operations Manager (352) 201-2770
Toll Free 24/7 (800) 240-5677

WARRANTY POLICY
4
Sierra Dental Products Limited Warranty
Warranty for the EAGLE12 VX oil-less compressor is limited to the original
purchaser of the unit. Sierra Dental Products is only obligated under this warranty
to the repair or replacement of defective parts or materials. The defect(s) must be
reported to Sierra Dental Products within the valid warranty period.
Sierra Dental Products will examine the product to determine if the parts are
defective. Products that have been abused, neglected, or damaged by being
improperly installed/maintained are not covered by this warranty. We are not
responsible for work performed on the unit by any unauthorized service agents.
Warranty Period
Warranty is valid only with the return of the warranty card within 30 days of
purchase for a period of 3 years.
Warranty Service and Return Policy
To obtain warranty service, product must be returned to Sierra Dental Products for
examination at the purchaser’s expense. All returns must be authorized and a
return material authorization (RMA#) number must be obtained from Sierra Dental
Products. Returned units must be properly packaged for shipping. We are not
responsible for shipping damages or shipping charges. Sierra Dental Products
will, at their discretion, repair or replace defective parts.**PLEASE NOTE** there is
a 25% re-stocking fee on all returns.

SAFETY
WARNING
To prevent fire or electrical shock, do
not expose this unit to rain or
moisture, excessive heat or improper ventilation.
ATTENTION USERS
Alerts users of important operating
and maintenance instructions. Read
carefully to avoid any problems
Warns users of a potentially hot
surface and a danger of burns
Warns users that uninsulated voltage
is present and can cause electric
shock
5
Use of the Eagle VX not in compliance with the
instructions specified in this manual may result in
permanent failure and voided warranty of the unit.

1. IMPORTANT - This equipment:
a) Has hot, electrical, and moving parts;
b) May start or stop automatically, depending on the tank’s pressure or the tripping of electrical
protection elements;
c) May cause mechanical or electrical interferences in nearby equipment;
d) Must not be operated in places where non-authorized people, children, or animals may have
access;
e) Requires an authorized person to supervise its use and ensure proper maintenance;
f) Must be installed and operated in areas well ventilated and protected against humidity and
water;
g) Must be installed and operated in areas that do not exceed 104 degrees Fahrenheit.
2. Never exceed the maximum pressure of 115 psi.
3. Before any maintenance, be sure the equipment is unplugged and not energized.
4. Never change the adjustment of the safety valve or pressure switch. They are factory regulated and any
adjustments out in the field could void your warranty. If any adjustments to the pressure switch is
needed, call your authorized dealer for Sierra Dental Products.
5. Never perform welding jobs or repairs on the air pressure tank because this can affect its resistance or
disguise more serious problems. If there is any leakage, crack, or corrosion, immediately stop operating
the equipment and contact your authorized dealer for Sierra Dental Products.
6. Air compression is a heat generating process. The pump unit and tubes are subject to high
temperatures. Therefore, one must be careful when handling them in order to avoid burns.
7. Before connecting the compressor to a power supply, verify that all electrical fittings are tight.
8. Never use solvents to clean your compressor.
1. The use of solvents or paint accumulation may cause explosion risks and irreversible damage
to the product in general. Cleaning products and the environment may not contain solvents.
9. Do not remove the attached accessories when the compressor is pressurized. Do not clean or touch
the electric components without unplugging the compressor from the electrical power supply. Not
following the orientations may cause physical and material damage.
10. In case of any irregularities with the equipment, stop operating it immediately and contact your
authorized dealer for Sierra Dental Products.
SAFETY CONTINUED
6

SYSTEM LAYOUT
Air muffler & Auto purge
½” Discharge connection
7
Compressor heads
Pressure switch
Tank
Power cord
Low voltage control box
Desiccant dryer
Drain petcock
Remote wires
Purge shut off valve
Inlet Filters (x4)
Purge silencer
On/off switches

SYSTEM LAYOUT
8
Coalescing filter
Pressure gauge
Fan shroud
Rubber feet
Handle
ASME Safety valve
Pressure switch
Tank inlet check valve
Stainless steel braided
air hose

SPECIFICATIONS
SITE REQUIREMENTS
9
Voltage 230 V AC
Circuit breaker rating 20 Amp
Minimum wire size 14 Gauge
Minimum trunk line size ½”
Max ambient temp. 104°F
Minimum ambient temp. 41°F
This equipment must be installed in a well ventilated mechanical room to
prevent over heating and failure not covered by the warranty.
Description Specification
Model # EGL-12VX
Max users 6
Air dryer Yes
Number of heads 2
Total horsepower 2
CFM 8.75
Tank gallons 27 g
Voltage 230 V AC
Amps 14
Decibels 74
Weight 201 lbs
Height 32”
Width 37”
Depth 24”

INSTALLATION
1. Location: Install the compressor in a covered, well ventilated area, free of dust, gases,
toxic gases, humidity, or any other kind of pollutant. The maximum ambient
temperature recommended during operation is 104 degrees Fahrenheit.
a. IMPORTANT: Avoid installation in small places such as a storeroom or closet..
2. Position: Mount at least 32 inches (800mm) from any obstacle, to allow good ventilation
during operation and to make maintenance easier.
a. Compressor Installation: When connected to the air network, the discharge
connection must be joined by means of a hose or expansible gaskets so that the
charges, thermal expansion, piping’s weight, mechanical and thermal shocks or
obstructions are not transmitted to the air tank. Physical damage to the
compressed air tank may occur if the above warnings are not followed.
3. Foundation/Floor: The compressor must be placed on a concrete base, which must be
able to bear the equipment’s weight. The equipment must be level. The compressor is
equipped with rubber feet (Assembled by installer)
4. Electric Connection:
a. Consult a specialized electrician to evaluate the electrical power supply and to
select the adequate protections and input devices, and to perform the
installation service.
10
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Beliebte Kompressor Handbücher anderer Marken

Emerson
Emerson Copeland Scroll Digital HLR Series Bedienungsanleitung

Drawmer
Drawmer 1968 MKII Bedienungsanleitung

Badger Air-Brush
Badger Air-Brush X-Air 80-8 Bedienungsanleitung

Omnitronic
Omnitronic CL-166 Bedienungsanleitung

Scheppach
Scheppach HC24V Montageanleitung

Ingersoll-Rand
Ingersoll-Rand centac C950 Technisches Handbuch