Sigrand SG-16G Bedienungsanleitung

SIGRAND
SHDSL modem
Sigrand SG-16G
User's Guide
v. 2.4
Novosibirsk
2006
1

© 2005, 2006 Sigrand LLC
All trademarks and registered trademarks mentioned hereina ter are the
property o their respective owners.
2

Contents
Contents page
How to use this Guide 5
1. Modem description 7
1.1 DSL inter ace speci ications 8
1.1.1 Maximum reach per ormance 8
1.2 E1 inter ace speci ications 9
1.3 RS-232C inter ace speci ications 10
1.4 Power supply unit 10
1.5 Miscellaneous data 10
1.6 Shipment contents 10
1.7 Environmental speci ications 11
1.8 Appearance, controls, indicators and connectors 11
1.8.1 Front panel and indicators 11
1.8.2 Rear panel and connectors 12
2. Modem setup directions 15
2.1 Connecting modem to a line 15
2.1.1 Requirements to a communication line 15
2.2 Choosing modem management method 16
2.3 ”Master”/”slave” mode 16
2.4 Setting DSL rate 16
2.4.1 Rate selection guidelines 17
2.4.2 Automatic rate selection 17
2.5 E1 inter ace setup 17
2.5.1 Connecting E1 inter ace 17
2.5.2 Con iguring Е1 inter ace 18
3. Modem management via console port 19
3.1 Terminal setup 19
3.2 General purpose commands 19
The help command 20
The info command 20
The stat command 21
The default command 21
The reboot command 21
3.3 DSL inter ace management 22
3

The help dsl command 22
The dsl command 22
3.3.1 “Master”/”slave” mode selection 23
The dsl master and dsl slave
commands
23
3.3.2 Setting DSL rate 23
The dsl rate command 23
3.3.2.1 Automatic rate selection 23
The dsl rate auto command 23
3.3.3 Line coding selection 24
The dsl code command 24
3.3.4 Link statistics 25
The dsl stat command 25
The dsl stat reset command 25
3.3.5 How to orce a retrain 26
The dsl retrain command 26
3.4 Е1 inter ace management 26
The help e1 command 26
The e1 command 27
3.4.1 Long/Short Haul modes 27
The e1 short and e1 long commands 27
3.4.2 Framing modes and super rame options 27
The e1 framed and e1 /framed
commands
27
3.4.3 Е1 line coding 28
The e1 code command 28
3.4.4 Е1 inter ace statistics 29
The e1 stat command 29
3.4.5 Timeslot map 30
The e1 map command 30
3.4.5.1 Timeslot 0 33
3.4.5.2 Timeslot 16 33
3.4.6 E1 inter ace behavior in the Automatic DSL rate
selection mode
34
4. Updating built-in modem irmware 36
4

How to use this Guide
To ease using this Guide the ollowing notational conventions are provided
here ( icons as well as relevant onts):
Icons
Icon Meaning Explanation
Pay attention!
The text marked by this icon contains
in ormation making easy setup and
maintenance o equipment
Important
in ormation!
The text marked by this icon contains
important in ormation explaining
details o operation o equipment or
so tware. This allows to save your
time and e orts while equipment
setup.
Do not make this!
Knowing this in ormation allow you to
avoid actions that can cause damage
to hardware and/or personal injury.
5

Font usage
Designation Explanation
Picture on the screen This ont shows contents o terminal
screen while modem setup.
Name o keyboard button
This ont shows computer keyboard
buttons, e.g. ”Enter”, which are used
in the console management mode.
Select Property in the File menu
Italic notes the ragments o this
Guide containing important
in ormation (together with the relevant
icons). It also marks so tware buttons
o menu in the text.
dsl stat
Bold ont is used to designate
modem management commands
while a terminal session.
Before starting installation of the modem we recommend you
to look for a updated version of this User's Guide as well as
the firmware and the drivers available at our site
www sigrand com
6

1. Modem description
The Sigrand SG-16G modem is a SНDSL-modem. It eatures an E1 system
inter ace (ITU-T G.703/G.704, 2048 kbps) and is intended to be used as a
line termination unit o TDM-based communication equipment. The modem
allows to make connections between devices equipped with E1 inter aces
such as telco equipment, routers and access servers.
The SHDSL inter ace o the modem con orms to ITU-T G.991.2.bis standard
and uses ТСРАМ (Trellis-Coded Pulse Amplitude Modulation) line coding.
Features o the ТСРАМ line coding:
The ТСРАМ line coding used by G.991.2 (G.SHDSL) compatible modems
has a ew modes. The modes di er in complexity o coding algorithm. The
modes with larger number o modulation positions (ТСРАМ16, ТСРАМ32)
are applicable or higher rates, the modes with less number o modulation
positions (ТСРАМ4, ТСРАМ8) are applied or lower rates. Respectively, the
more complicated the coding algorithm the worse the channel noise
immunity and vice versa.
So take special attention to the ТСРАМ line coding algorithm selection while
con iguring the line rate. It may be necessary to change the line coding to
achieve the best result.
Table 1 shows the line coding options and respective data rate ranges.
Table 1
Line coding Data rate range (kbps)
TCPAM32 256 – 2048
TCPAM16 192 – 2048
TCPAM8 192 – 1216
TCPAM4 64 – 704
Manual line coding selection is available only in the console
management mode – see chapter 3 of this Guide
7

Compatibility:
The Sigrand SG-16G modem line coding is compatible with all Sigrand SG-
16 series and Granch SBNI16 series modems.
The modem eatures the ollowing inter aces:
•one SHDSL inter ace (con orms to ITU-T G.991.2.bis standard)
providing the data rate range rom 64 to 2048 kbps.
•one Е1 inter ace (G.703/G.704, 2048 kbps).
•one EIA-232C (RS-232C) inter ace or modem management.
1.1 DSL inter ace speci ications
Link type point-to-point
Number o wires per line 2 (one pair)
Permitted cabling any UTP
Line coding TCPAM
Input/output impedance, Ω135
Data rate range, kbps 64-2048
Data rate step, kbps 64
Transmission type ull duplex
Data trans er mode synchronous, by
packets
Packet type HDLC
Checksum type CRC32
Connector type RJ-45
Galvanic decoupling trans ormer breakdown
voltage, min, V
1500
Surge protector triggering voltage (di erential), V 30
Arrester breakdown voltage (common-mode), V 350
1.1.1 Maximum reach per ormance
Brie in ormation about the maximum reach per ormance o the Sigrand SG-
16G modem is shown on Table 2. The Bit Error Rate (BER) at the maximum
reach is equal to or less than 10-7. The speci ied reach is proved by testing
at the Sigrand lab re erence line. Full version o the rate table is available at
8

our site www.sigrand.com. An actual reach may vary against the shown
data due to variations o cable per ormance.
Table 2
Data rate
(kbps) Line coding Rating
TPP50-0.4
cable
(26 AWG)
TPP50-0.5
cable
(24 AWG)
2048 TCPAM16 Length (km/ t) 3.8/12400 5.6/18300
R (Ω)1064 980
1536 TCPAM16 Length (km/ t) 4.4/14400 6.4/20100
R (Ω)1232 1120
1024 TCPAM8 Length (km/ t) 5.0/16400 7.6/24900
R (Ω)1400 1330
512 TCPAM8 Length (km/ t) 5.8/19000 9.0/29500
R (Ω)1624 1575
256 TCPAM8 Length (km/ t) 6.6/21600 10.0/32800
R (Ω)1848 1750
128 TCPAM4 Length (km/ t) 7.4/24200 11.4/37400
R (Ω)2072 1995
64 TCPAM4 Length (km/ t) 7.4/24200 11.4/37400
R (Ω)2072 1995
1.2 E1 inter ace speci ications
Type o inter ace RJ-45, Balanced
Number o wires per line 4
Line coding HDB3, AMI
Data rate, kbps 2048
Maximum reach, km ( t)
TPP50-0.4 cable (26 AWG) 1.2 (3900)
TPP50-0.5 cable (24 AWG) 2.4 (7800)
Frame type G.704
Super rame types CRC4, CAS
9

Un ramed mode available
1.3 RS-232C inter ace speci ications
Baud rate 9600, 57600
Protocol parameters 8-N-1
Flow control N/A
Connector type RJ-45 (DB-9F with converter)
1.4 Power supply unit
Type BPN-12-1V
Input voltage 220V/50Hz
Output voltage 12V
Maximum load current 1A
Polarity o the central contact o the connector positive
1.5 Miscellaneous data
Overall modem dimensions:
• height, mm/in. 45/1.77
•width, mm/in. 225/8.86
•depth, mm/in. 165/6.5
Weight, g/lb 450/1
Weight with PSU, g/lb 1050/2.32
Power consumption, W 6
1.6 Shipment contents
Sigrand SG-16G modem 1 pc.
Power supply unit 1 pc.
Guide 1 pc.
Cable with converter RJ-45-DB-9 1 pc.
Package 1 pc.
10
Inhaltsverzeichnis
Andere Sigrand Modem Handbücher
Beliebte Modem Handbücher anderer Marken

Davicom
Davicom DM562AP Bedienungsanleitung

EpiValley
EpiValley TATA indicom SXC-1080 Bedienungsanleitung

Zte
Zte WiMAX Bedienungsanleitung

Intelimax
Intelimax MA-2060 Bedienungsanleitung

SMC Networks
SMC Networks D3CM1604V Gebrauchs- und Pflegehandbuch

Telstra
Telstra Wi-Fi 4G Advanced Pro X Bedienungsanleitung

US Robotics
US Robotics 3453C Bedienungsanleitung

MaxTech
MaxTech Plug & Play Internal Voice/FAX/Data/SVD... Bedienungsanleitung

Zte
Zte MF823 Bedienungsanleitung

Four-Faith
Four-Faith F1403 Bedienungsanleitung

Sierra Wireless
Sierra Wireless AIRLINK MP595W Bedienungsanleitung

Gemtek
Gemtek WiMAX WIXFBR-103 Bedienungsanleitung