1 General safety instructions.....................................................................................................................4
2 Product-specific safety instructions....................................................................................................6
3 Meaning of the text formatting ............................................................................................................. 7
4 Product description...................................................................................................................................8
5 Before placing an order............................................................................................................................9
5.1 SmartRelay .........................................................................................................................................................9
5.2 Determining the number of required modules..................................................................................9
5.3 Acquiring and configuring power supply units...................................................................................9
5.4 Determining installation technology and location ..........................................................................9
5.5 Cable types and routes.................................................................................................................................9
5.6 installation outside..........................................................................................................................................9
5.7 Guidelines ............................................................................................................................................................9
6 Before installation ................................................................................................................................... 10
7 Installation ...................................................................................................................................................11
8 Connections................................................................................................................................................12
9 Connection to the SmartRelay .............................................................................................................15
9.1 Standard power supply unit connection............................................................................................ 15
9.2 Connecting a fire alarm system emergency release .................................................................... 16
9.3 Circuit to prevent opening if power supply should fail ................................................................ 16
10 Programming and configuration......................................................................................................... 18
10.1 General information...................................................................................................................................... 18
10.2 Entering the number of modules ........................................................................................................... 18
10.3 Configuring the address for modules................................................................................................... 18
10.4 Setting the pulse length.............................................................................................................................. 19
10.5 Naming in the software............................................................................................................................... 19
10.6 Inverting outputs ............................................................................................................................................ 19
11 Signal ............................................................................................................................................................21
11.1 LEDs for each output ....................................................................................................................................21
11.2 Status LED..........................................................................................................................................................21
12 Technical specifications ........................................................................................................................22
13 EU/UK Declaration of conformity.......................................................................................................25
SOM + SREL3.ADV (Manual) Content
2 / 27

1 General safety instructions
Signal word (ANSI
Z535.6) Possible immediate effects of non-compliance
DANGER Death or serious injury (likely)
WARNING Death or serious injury (possible, but unlikely)
CAUTION Minor injury
IMPORTANT Property damage or malfunction
NOTE Low or none
WARNING
Blocked access
Access through a door may stay blocked due to incorrectly fitted and/or in-
correctly programmed components. SimonsVoss Technologies GmbH is
not liable for the consequences of blocked access such as access to in-
jured or endangered persons, material damage or other damage!
Blocked access through manipulation of the product
If you change the product on your own, malfunctions can occur and access through a door can
be blocked.
Modify the product only when needed and only in the manner described in the
documentation.
IMPORTANT
Damage resulting from electrostatic discharge (ESD)
This product contains electronic components that may be damaged by electrostatic discharges.
1. Use ESD-compliant working materials (e.g. Grounding strap).
2. Ground yourself before carrying out any work that could bring you into contact with the
electronics. For this purpose, touch earthed metallic surfaces (e.g. door frames, water pipes
or heating valves).
Damage resulting from liquids
This product contains electronic components that may be damaged by liquids of any kind.
Keep liquids away from the electronics.
Damage resulting from aggressive cleaning agents
The surface of this product may be damaged as a result of the use of unsuitable cleaning agents.
Only use cleaning agents that are suitable for plastic or metal surfaces.
SOM + SREL3.ADV (Manual) 1. General safety instructions
4 / 27

Damage as a result of mechanical impact
This product contains electronic components that may be damaged by mechanical impacts of
any kind.
1. Avoid touching the electronics.
2. Avoid other mechanical influences on the electronics.
Damage as a result of overcurrent or overvoltage
This product contains electronic components that may be damaged by excessive current or
voltage.
Do not exceed the maximum permissible voltages and/or currents.
Damage due to polarity reversal
This product contains electronic components that may be damaged by reverse polarity of the
power source.
Do not reverse the polarity of the voltage source (batteries or mains adapters).
NOTE
Intended use
SimonsVoss-products are designed exclusively for opening and closing
doors and similar objects.
Do not use SimonsVoss products for any other purposes.
Different times for G2 locks
The internal time unit of the G2 locks has a technical tolerance of up to ± 15 minutes per year.
Qualifications required
The installation and commissioning requires specialized knowledge.
Only trained personnel may install and commission the product.
Incorrect installation
SimonsVoss Technologies GmbH accepts no liability for damage caused to doors or compon-
ents due to incorrect fitting or installation.
Modifications or further technical developments cannot be excluded and may be implemented
without notice.
The German language version is the original instruction manual. Other languages (drafting in the
contract language) are translations of the original instructions.
Read and follow all installation, installation, and commissioning instructions. Pass these instruc-
tions and any maintenance instructions to the user.
SOM + SREL3.ADV (Manual) 1. General safety instructions
5 / 27

2 Product-specific safety instructions
IMPORTANT
SimonsVoss Technologies GmbH accepts no liability for any damage
caused by incorrect installation.
IMPORTANT
You must observe the manufacturer's warranty and installation conditions
if you use other manufacturers' products with a SmartOutput module.
SOM + SREL3.ADV (Manual) 2. Product-specific safety instructions
6 / 27

3 Meaning of the text formatting
This documentation uses text formatting and design elements to facilitate
understanding. The table explains the meaning of possible text formatting:
Example button
Example
Example checkbox
Example Option
[Example] Tab
"Example" Name of a displayed window
|Example| Upper programme bar
Example Entry in the expanded upper pro-
gramme bar
Example Context menu entry
▼ Example Name of a drop-down menu
"Example" Selection option in a drop-down
menu
"Example" Area
Example Field
Example
Name of a (Windows) service
Example
Commands (e.g. Windows CMD
commands)
Example Database entry
[Example] MobileKey type selection
SOM + SREL3.ADV (Manual) 3. Meaning of the text formatting
7 / 27

4 Product description
The SmartOutput module features eight potential-free relay outputs,
which can be actuated using SmartRelay Advanced. Depending on the
transponder ID, one or several outputs can be activated for a
programmable time interval. This assignment (profile) is freely
programmable in LSM.
This means that the SmartOutput module is suitable for functions such as:
Authorisation-dependent lift control
Activation to open mail box systems
Up to fifteen modules can be connected to a SmartRelay if more than
eight outputs are needed.
SOM + SREL3.ADV (Manual) 4. Product description
8 / 27

5 Before placing an order
5.1 SmartRelay
At least one SmartRelay is required to operate a SmartOutput module. To
order a SmartRelay, read the manual concerned on the required
SmartRelay or contact us (see Help and contact).
5.2 Determining the number of required modules
Up to fifteen external modules can be connected to a SmartRelay 3
Advanced. Each module can be configured separately from one another
using the software.
Only four outputs are available on module 15 (up to 116 additional outputs
in total).
5.3 Acquiring and configuring power supply units
SmartRelay and up to eight SmartOutput modules can be operated with a
power supply unit. The power supply unit must be able to deliver a suitable
output voltage (recommended: 12VDC) and provide sufficient current (see
Technical specifications [}22]
for power input).
5.4 Determining installation technology and location
SmartOutput modules are fastened to DIN rails. SmartRelay are not
usually fitted to DIN rails.
5.5 Cable types and routes
SmartOutput modules should be fitted in such a way that all cables can be
installed without bending them too much.
5.6 installation outside
Modules are not designed for outdoor installation without additional
protective measures.
5.7 Guidelines
Specialist trained to EN 18328 requirements should install the module. VDE
guidelines must be observed.
SOM + SREL3.ADV (Manual) 5. Before placing an order
9 / 27

6 Before installation
1. Unpack the SmartOutput module.
2. Check the SmartOutput module for external damage.
3. Connect the SmartOutput module and a reader to a SmartRelay.
4. Power the SmartOutput module.
IMPORTANT
Reverse polarity damages electronics
If you connect the power supply with the wrong polarity, the electronics will
be damaged.
Observe the polarity.
9SmartOutput module "rattles" when the power supply is connected.
9SmartOutput module flashes red once every 16 seconds.
5. Power the SmartRelay.
9SmartRelay detects SmartOutput module.
9SmartOutput module flashes very quickly red/green for one second.
9SmartOutput module has been detected and flashes green once every
ten seconds.
SOM + SREL3.ADV (Manual) 6. Before installation
10 / 27
Inhaltsverzeichnis
Andere Simons Voss Technologies Steuereinheit Handbücher
Beliebte Steuereinheit Handbücher anderer Marken

Festo
Festo Compact Performance CP-FB6-E Stücklistenhandbuch

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Bedienungsanleitung

JS Automation
JS Automation MPC3034A Bedienungsanleitung

JAUDT
JAUDT SW GII 6406 Series Kurzanleitung

Spektrum
Spektrum Air Module System Bedienungsanleitung

BOC Edwards
BOC Edwards Q Series Bedienungsanleitung