DU35K/FDM –Instruction Manual Page 9
IP ADDRESS
SUBNET MASK
DEFAULT GATEWAY
The display's IP address, subnet mask, and default gateway are set in accordance with the data
of the existing network to which you intend to connect the display.
A DHCP client is integrated in the display, which can set alone in relation with a DHCP server (if
provided in the network) all the proper network settings. The DHCP client is activated if “DHCP:
Y” is chosen. If “DHCP: N” is chosen, the client is switched off and all the network settings should
be set manually.
If the DHCP client is switched on, then menus »subnet mask« and »default gateway« can only
be inspected but not changed.
MODE
Here you can choose content for each of the three display’s line. As usually, you can choose
between values by a longer press of the SET key.
Possible values:
TD –time deviation, +/- SS.mmm
F –power line frequency, FF.xxx
FD –frequency deviation, +/-FF.xxx
REF –reference time, HH:MM:SS
PLT –power line time, HH:MM:SS
BLK –line will remain blank
UPDATE TIMEOUT
If FDM strings are not available for some reason, a timeout will appear. Here you can set timeout
period in seconds. If it’s set to 0, timeout event won’t occur and the last known values will be
shown.
TIMEOUT ALARM
In case of data communication timeout event (after the time set in previous submenu), the
display can either blink the last values or clear display. In this submenu you choose between
both options.
EXIT
If you press the SET key, the display returns to the normal displaying of time and messages. If
there were changes in settings, you’ll have to confirm that you really want to apply them.
However, if you press the MENU key, the display begins a new circle of settings.