INSTALLING THE AUTO DIALER
ELECTRICAL SHOCK HAZARD
Disconnect power before installing or servicing this
product. A qualified service person must install and
service this product according to applicable electrical
and plumbing codes.
EXPLOSION OR FIRE HAZARD
Do not use this product with flammable liquids.
Do not install in hazardous locations as defined by
National Electrical Code, ANSI/NFPA 70.
Failure to follow these precautions could result in serious injury or death. Replace product immediately if switch cable becomes damaged
or severed. Keep these instructions with warranty after installation. This product must be installed in accordance with National Electric Code,ANSI/
NFPA 70 so as to prevent moisture from entering or accumulating within boxes, conduit bodies, fittings, float housing, or cable.
TESTING THE AUTO DIALER
PROGRAMMING THE AUTO DIALER
PROGRAMMING TIPS
FIGURE A
TWO NORMALLY CLOSED CONTACTS
FIGURE B
TWO NORMALLY OPEN CONTACTS
Note: Temperature switch can also be used by itself. See
Figure C.
FIGURE C
Note:Theseinstructionsareintendedasaquickreferenceforthemost
common installation of the Auto Dialer when used with a control
panel. For complete instructions, see the included Installation
and Instruction Manual for the Automatic Voice Dialer. Before
beginning installation, read the entire instruction manual for the
AVD-45b Automatic Voice Dialer.
1. Determine indoor mounting location for the Auto Dialer.
2. IfmountingtheAutoDialertothewall,usethetwosuppliedscrews.
Install the screws parallel and level 5 3/16 inches apart.
3. Install the four conductor power/alarm cable into a control panel
using only the white and yellow conductors. The conductors can
be attached to normally open or normally closed contacts. Note:
Trim the red and black conductors flush with outer jacket of the
cable. (See Figures A & B for optional wiring methods.)
4. Installthetwoconductortelephonecablebymatchingtheappropriate
colors to a telephone service or by installing an appropriate
connector.
5. Install the 9 VDC battery if backup power is desired. Note: The
battery will supply approximately four hours of backup power.
Replace battery yearly and after each power outage.
6. Hangtheautodialeronthetwomountingscrewspreviouslyinstalled.
7. Connect the phone cable and power/alarm cable to the auto dialer
using the supplied connectors.
8. Installthebarrelconnectoronthepowersupplyintotheconnection
labeled 12V standby battery.
9. Plug the DC power supply into a standard outlet.
1. ProgramtheAutoDialeraccordingtotheUnitedSecurityProducts
Model AVD-45b Automatic Voice Dialer instruction manual.
2. Be sure to note if normally open or normally closed contacts are
used to trigger the Auto Dialer. This will have to be programmed
into the Auto Dialer.
1. When programming for pagers, call the desired pager from the
telephone number and telephone line that the Auto Dialer will
be attached to. Record the time required for the pager service to
answer. Use that time for programming the required number of
pauses needed. Each pause is two seconds in length.
2. If a cell phone does not ring before the Auto Dialer hangs up,
program the cell phone number into the Auto Dialer with pauses
afterthenumber.Note:Thenumber ofpauseswilldependoneach
cell phone and must be tested.
3. If a delay is desired before theAuto Dialer calls out to help prevent
nuisance calls, set the entry delay to "on" and the channel to
"continuous" mode. This will require that channel activation to be
tripped for 20 seconds before dialing out and remain activated
throughout the dialing process.
1. All people or organizations should be notified that the auto dialer
will be calling and the action you would like them to take.
2. Apply power to the unit.
3. Be sure an active telephone line and all wiring is connected to the
auto dialer.
4. Press the "M" key until "Operate" appears in the LCD.
5. Trigger the signaling device to cause the auto dialer to call out.
6. The auto dialer will dial the numbers stored in locations 1-4. The
out going message will be delivered when the auto dialer receives
an answer. For pager numbers, the pager code will be transmitted
instead of the outgoing message.
7. The auto dialer is now ready for operation.
8. Test the Auto Dialer system once a month to insure the outgoing
message is being sent and received.
For detailed specifications on this product, or for the complete line of SJE-Rhombus®
panel, alarm, and switch products, visit our web site at www.sjerhombus.com.
Note: The Auto Dialer AVD-45b will attempt to deliver the outgoing message twice with a maximum of 10 attempts for each telephone number.
Note: This device should not be used for life saving applications.