SCU Fault Codes MC_0651
Fault Code Description Cause Action
100.0.0 System Error - - Internal Error -Consult Sleipner dealer
201.0.200 NMEA2000 Transmission parameter -
Timeout
No NMEA2000 (pgn127493) transmission message received
for 2seconds.
-Check if GW-1 status is ok by checking the GW-1 status LED (See
GW-1 user manual).
-Check cabling
10101.0.11 Device CPU Temp - Level High CPU temperature higher than 85 degrees. -Ventilate the room were the ECU is sitting.
-Consult Sleipner dealer
35000.0.200 GPS signal lost - Timeout No GPS data from GW-1 received for 3 seconds
-Check if GW-1 status is ok by checking the GW-1 status LED (See
GW-1 user manual).
- Check cabling
40001.0.201 SCU Sensor board fault 1 - INIT FAIL Sensor board fault. -Consult Sleipner dealer
40001.0.202 SCU Sensor board fault 1 - READ FAIL Sensor board fault. -Consult Sleipner dealer
40002.0.201 SCU Sensor board fault 2 - INIT FAIL Sensor board fault. -Consult Sleipner dealer
40002.0.202 SCU Sensor board fault 2 - READ FAIL Sensor board fault. -Consult Sleipner dealer
40003.0.201 SCU Sensor board fault 3 - INIT FAIL Sensor board fault. -Consult Sleipner dealer
40003.0.202 SCU Sensor board fault 3 - READ FAIL Sensor board fault. -Consult Sleipner dealer
40004.0.24 PHC-3 - Fault Detected fault on PHC-3 -Check PHC-3 faults for more information
40004.0.100 PHC-3 - No Communication PHC-3 Communication lost for more than 500ms -Check if PHC-3 is powered and is working
-Check S-Link cabling
40004.0.200 PHC-3 - Timeout PHC-3 startup timed out. Trigger when startup takes longer
than 60 seconds
-Check if PHC-3 is able to build up the pressure.
-Check PHC-3 faults for more information.
-Check PHC-3 system pressure reading when PTO is not running
against PHC-3 parameter 1009-PTO PUMP PRESSURE DETECT
LEVEL.
-Check PHC-3 system pressure sensor.
40004.0.210 PHC-3 - DEVICE IN MANUAL MODE Trigger when the SCU try to startup PHC-3 and the PHC-3 is
running in manual mode. -Stop running the PHC-3 in manual mode
40006.0.24 SCU Sensor board fault 4 - Fault Sensor board fault. -Consult Sleipner dealer
40006.0.150 SCU Sensor board fault 4 - ID Fault Sensor board fault. -Consult Sleipner dealer
40006.0.151 SCU Sensor board fault 4 - Self-Test Fault Sensor board fault. -Consult Sleipner dealer
40006.0.203 SCU Sensor board fault 4 - Not Calibrated Sensor board fault. -Consult Sleipner dealer
40007.0.100 SCU Sensor board fault 5 - No Communi-
cation Sensor board fault. -Consult Sleipner dealer
40007.0.150 SCU Sensor board fault 5 - ID Fault Sensor board fault. -Consult Sleipner dealer
40008.0.24 SCU Sensor board fault 6 - Fault Sensor board fault. -Consult Sleipner dealer
40009.0.150 SCU Sensor board fault 7 - ID Fault Sensor board fault. -Consult Sleipner dealer
40009.0.151 SCU Sensor board fault 7 - Self-Test Fault Sensor board fault. -Consult Sleipner dealer
40010.0.150 SCU Sensor board fault 8 - ID Fault Sensor board fault. -Consult Sleipner dealer
40011.0.150 SCU Sensor board fault 11 - ID Fault Sensor board fault. -Consult Sleipner dealer
40012.100.51 FCU Current Fin bow port Current High Current to the FCU is too high. Trigger at 10A. -Check cabling between SCU and FCU for short circuit.
40012.101.51 FCU Current Fin bow starboard Current High Current to the FCU is too high. Trigger at 10A. -Check cabling between SCU and FCU for short circuit.
40012.102.51 FCU Current Fin stern port Current High Current to the FCU is too high. Trigger at 10A. -Check cabling between SCU and FCU for short circuit.
40012.103.51 FCU Current Fin stern starboard Current High Current to the FCU is too high. Trigger at 10A. -Check cabling between SCU and FCU for short circuit.
45000.100.21 FCU Tuning Fin bow port Failed Tuning sequence has failed. Trigger if fi n movement is less
than 50 degrees.
-Run bleeding to get rid of air in the hydraulic system
-Check encoder belt and pulleys.
45000.101.21 FCU Tuning Fin bow starboard Failed Tuning sequence has failed. Trigger if fi n movement is less
than 50 degrees.
-Run bleeding to get rid of air in the hydraulic system
-Check encoder belt and pulleys.
45000.102.21 FCU Tuning Fin stern port Failed Tuning sequence has failed. Trigger if fi n movement is less
than 50 degrees.
-Run bleeding to get rid of air in the hydraulic system
-Check encoder belt and pulleys.
45000.103.21 FCU Tuning Fin stern starboard Failed Tuning sequence has failed. Trigger if fi n movement is less
than 50 degrees.
-Run bleeding to get rid of air in the hydraulic system
-Check encoder belt and pulleys.
45001.100.21 FCU Encoder Fin bow port Failed Encoder fault
-Run bleeding to get rid of air in the hydraulic system
-Check encoder belt and pulleys.
-Check if something is blocking the actuators
-Check if all the hydraulics mounted correctly to the actuators.
-Check if a PHC-3 fault is present.
45001.100.22 FCU Encoder Fin bow port Out off position Encoder position is outside the end stop position.
-Run the detect end stop sequence.
-Check encoder belt and pulleys.
-Consult Sleipner dealer
45001.100.209 FCU Encoder Fin bow port MOTION FAULT Encoder position do not change. Check encoder belt, encoder cable or if the fi n is locked in one
position.
45001.101.21 FCU Encoder Fin bow starboard Failed Encoder fault
-Run bleeding to get rid of air in the hydraulic system
-Check encoder belt and pulleys.
-Check if something is blocking the actuators
-Check if all the hydraulics mounted correctly to the actuators.
-Check if a PHC-3 fault is present.
45001.101.22 FCU Encoder Fin bow starboard Out off
position Encoder position is outside the end stop position.
-Run the detect end stop sequence.
-Check encoder belt and pulleys.
-Consult Sleipner dealer
45001.101.209 FCU Encoder Fin bow starboard MOTION
FAULT Encoder position do not change, Check encoder belt, encoder cable or if the fi n is locked in one
position.