Introduction
3
ATTENTION
From the serial number SN1249 of the FB700 module, SerialDownload (software to download the
firmware) version V3.4.0.0 or higher and firmware version V3.46J or higher is necessary.
The software and firmware compatible with the new version of the module are available from System302
V7.0.6. For previous versions of System302, the upgrade for SerialDownload and firmware can be
downloaded from the FB700 page at the Smar website (www.smar.com.br).
WARNING
The previous versions from firmware 3.46J may be downloaded to the module (with the SerialDownload
software version above), but the characteristics of saving non-volatile data during the shutdown will be
lost. (Non-volatile data are dynamic data saved during the power down, such as the OUT parameter from
the Integrator block, or SP, OUT and BKCAL_IN parameters from the PID block). For more information
refer to the Function Blocks User’s Manual.

FB-700 – User’s Manual
4

FB-700 – Fieldbus Module
5
FB-700 – Fieldbus Module
(Supports Hot swap and Device ID)
Part Number:
FB-700 - Fieldbus Module
Description
The FB-700 is a Fieldbus interface card for the LC700 programmable controller. It integrates the
discrete control capability of LC700 with Fieldbus.
The Foundation™ Fieldbus interoperability feature assures that the FB-700 will work perfectly with
any other FF device, even from manufacturers other than Smar.
The FB-700 is directly attached to the LC700 backplane. The LC700 accesses it as a regular I/O
card, which supports many digital and analog I/O points mapped to the FB-700 function blocks. For
proper operation, both CONF700 and SYSCON should configure the card.
Function Blocks
FB-700 can execute the following function blocks, some of which are pre-instantiated:
Block Type Description Number of
Instantiations
RS Resource 1
DIAG Diagnostics Transducer 1
MAI Multiple Analogic Inputs 2
MDI Multiple Discrete Inputs 3
PID PID Control 1
EPID Enhanced PID Control 0
ARTH Arithmetic 0
SPLT Split Range 0
CHAR Signal Characterizer 0
INTG Integrator 0
AALM Analogic Alarm 1
ISEL Input Selector 0
SPG Set point Ramp Generator 0
TIME Time and Logic 0
LLAG Lead-Lag 0
OSDL Output Selector/Dynamic Limiter 0
CT Constant 0
MAO Multiple Analogic Output 2
MDO Multiple Discrete Output 4
In the table above:
- Block Type: it means the available block types for the device
- Description: it shows the description of each block.
- Number of instantiations:
0 – this block type is not pre-instantiated in the FB-700.
1 to 4 – it indicates the quantity of pre-instantiated blocks in the FB-700.
There are blocks that have correlation with the LC700. These blocks are described below:
Block Type Description LC700 Block
MDI Multiple Discrete Inputs CODD
MDO Multiple Discrete Outputs CIDD
MAI Multiple Analogic Inputs COAD
MAO Multiple Analogic Outputs CIAD

FB-700 – User’s Manual
6
Connecting FB-700 to LC700
Before connecting or disconnecting the FB-700 from the LC700 backplane, please be sure that the
LC700 power is OFF.
LEDs behavior
The FB-700 red and yellow LEDs indicate errors and warnings as described in the following tables:
Yellow Led
Always on FB-700 is saving nonvolatile data. After finishing this operation
the yellow led will be turned off.
Blinking at 1s
rate
LC700 and FB-700 do not have the same configuration
parameters. Please, check both SYSCON and LC700
configurations to ensure that the number of function blocks and
FB700 TAG are the same.
Blinking at 3s
rate There is a new configuration in the dual port memory, but the
LC700 does not check it.
Blinking at 5s
rate There is a new configuration in the dual port memory without
any MIO function block.
Red Led
Always on A critical error happened and FB-700 is in a permanent
failure state. FB-700 must be reset.
Blinking at 1s
rate
LC700 is not accessing FB-700. Possible causes are LC700
is not running properly, FB-700 is not present in LC700
configuration or rack addressing is wrong.
Firmware Version Changes and Updates
Using the “FBTOOLS” software, the user can change versions of the firmware in the Flash memory.
The FB-700 Module has a DB-9 connector for this purpose.
Follow the steps below to update and/or change the firmware for the FB-700 module:
1. Choose a serial port.
2. Connect the C232-700 cable to the FB700 and the PC serial port chosen in item 1.
3. Press FB700 RESET button to force download mode. The RED led will turn on.
4. Select and open the file FB700.ABS.
5. Click on Download button to start the firmware download.
6. Disconnect the C232-700 cable.
7. Press RESET button again to reset the FB700. The RED led will turn off.

FB-700 – Fieldbus Module
7
Notes:
1. Certify that no other application or resident program in the PC is using the I/O port or IRQ of the
selected serial port.
2. After resetting, the FB700 will automatically execute a factory initialization procedure (yellow led
will turn on), if necessary.
3. An LC700 system can have more than one FB module. The limit number of FB modules per
system is determined by the amount of the available configuration memory.
CABLE EIA-232 TO CONNECT FB-700
Part Number:
C232-700 – cable to connect FB-700 module to the PC
Description
This cable must be used in updating/changing the firmware version in the internal flash memory of
the FB-700 module.
CABLE EIA-232 TO CONNECT FB-700

FB-700 – User’s Manual
8
smar
+5VDC+5VDC+5VDC+5VDC
FAILFAIL
SAVINGSAVING
232232
FF0 (H1)FF0 (H1)
FB-700FB-700
ID & Hot-Swap
LC700/FB-700 Fieldbus Module
PGND
TX 1
2
3
7
8
RS-232
RX
GND
5V
0,5A
FF0 (H1)
1B
RESET
FACTORY INIT
2B
3B
4B
5B
6B
7B
8B
9B
10B
Fieldbus Module FB-700
Technical Specifications
CPU
Type Low Power Microcontroller
Architecture 8-bit CISC
MEMORY
Capacity Functionality
Code 512 kB, 8-bit Flash Downloadable firmware
Data 128 kB, 8-bit RAM Dynamic data
Retention 8 kB, 8-bit serial
EEPROM Configuration retention
Dual-Port 32 kB, 8-bit DPRAM LC700 interface
FIELDBUS INTERFACE
Number of Channels 1 H1 channel (31,25 Kbps)
Controller FB3050 SMAR (DMA Integrated)
Physical Layer Standard ISA-S50.02-1992
Fieldbus Interface Passive (not bus powered)
Intrinsic Safety NOT compliant
INTERNAL SOURCE
Supplied by the IMB bus 5 Vdc @ 110 mA
Total Maximum Dissipation 0.55 W
Source Indicator Green LED + 5 Vdc
TEMPERATURE
Operation 0 to 60 ºC
Storage -20 to 80 ºC
ISOLATION
IMB Communication Channel 500 Vac

FB-700 – Fieldbus Module
9
DIMENSIONS AND WEIGHT
Dimensions (W x H x D) 39.9 x 137.0 x 141.5 mm
(1.57 x 5.39 x 5.57 in)
Weight 0.261 kg
CABLES
One wire 14 AWG (2 mm2)
Two wires 20 AWG (0.5 mm2)
Installing the Module in the Rack
Follow the steps below to install the module in the rack.
Mounting a module in the rack:
oFind the border located
at the top of the free
slot.
oFit the hole, at the top
back of the module.
Mounting detail.
Lock the module in the connector
(slot) of the IMB by pushing it
against the rack.
Next, fix the module at the rack
using a screw driver, and fix the
locking screw at the bottom of the
module.

FB-700 – User’s Manual
10
Inhaltsverzeichnis
Andere SMAR Steuereinheit Handbücher
Beliebte Steuereinheit Handbücher anderer Marken

Festo
Festo Compact Performance CP-FB6-E Stücklistenhandbuch

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Bedienungsanleitung

JS Automation
JS Automation MPC3034A Bedienungsanleitung

JAUDT
JAUDT SW GII 6406 Series Kurzanleitung

Spektrum
Spektrum Air Module System Bedienungsanleitung

BOC Edwards
BOC Edwards Q Series Bedienungsanleitung