DOOR STATIONS DOOR RELEASE OPTIONS
about
56
inches
surface mount housing
_
SMP3 (for
NS3B
series)
in
or SME3D (for BD3B/D3B series) to the finished wall using
galvanized screws. Secure cables at master.
Figure
19
-
ME3
enclosure for all door Figure 20
-
SMP3
stations surface mount
enclosure
EXTERNAL MUSIC SOURCE
Figure 21
-
SME3D
surface mount
enclosure
External Music Sources (AWPM):
RED
Choose a location for the AWPM that
s$
will be easily accessible to the sources
that are to be connected to the system
,__
(close to the stereo receiver, TV or
VCR for example). At this location,
attach a single gang box to a wall stud
AwpMRx
at a center height of normal wall
outlets. Make sure the single gang box
extends past the wall stud and into the
room so it will be flush with the sheetrock
when it is applied. Run the Red and
Figure 22
-
AW PMRX
Black shielded audio cables (included
installation
in the AWPMRX) from the master unit location to the AWPM
location. Secure the audio cables with a loose knot after they
have been pulled through the single gang box. Secure the
cables at the master.
M&s
SYSTEMS
I
lllllllllln
11111111
115750 Rev B
The door release option is a momentary normally open dry
contact closure provided by the master with the installed
relay option. This dry contact is rated 24V at 4 Amps. The
sample applications below represent some
uses.
However, only one application can be used in any MC602
system at a time.
Door or Gate release mechanism: Run a
single line of PBVM127Xl from the
master unit location to the door release
mechanism. Connect the Red and White
$
wires to the two wires or terminals of the
i!
door release mechanism. Run another
1
single line of PBVM127Xl from the
g
master unit location to a gang box next to
a
120VAC
receptacle where the RTl 1
remote power transformer will be
plugged in. Label and secure cables at
Figure
2s
-
DRW
door
master. The door release switch contacts
release strike
are very versatile and can be used with many AC/DC door or
switch contacts. Be sure to use the wire and power supply or
transformer specified by the door or gate release being used.
Panic Interface with Security
System: Run a line of
PBVM127Xl
from
master unit location to the
securitv control oanel. Setuo
a normally open dry contact
or&tr&
for
panic
-
for panic operation. (Refer
to programming procedures
I
accompanying the security
panel). Label and secure
Flgure 24
-
Panic configuration
cables at master.
*
HomeMation
-
Home automation
interface (lights on, flash etc.) Run a
line of PBVM127Xl from the master
unit location to a gang box next to a
120VAC receptacle where a PF284
Power Flash module will be installed
later. Secure cable at master.
Figure
2cHome
automation hookup
M&S SYSTEMS
~-YEAR
“No
FAULT” LIMITED
WARRANTV
M&S Systems, Inc. warrants for two years (2) all products to be free of factory-caused defects
in material and workmanship. M&S Systems, Inc. will repair or replace, at its option, parts and
materials at no charge, regardless of the problem. This warranty extends to the original
purchaser of the product and to each subsequent owner of the product during the term of this
warranty. This NO FAULT warranty covers only the liability described above, and does not
include liability for incidental or consequential damages. NOTE: Some states do not allow the
exclusion or limitation of incidental or consequential damages, so the above limitation or
exclusion may not apply to you.
SMARTHOME.COM(TM) 1-800-SMART-HOME 949-221-9200 http://www.smarthome.com Order #5076