SMARTSCANMAGSAFE785093INSTALLATIONSHEETGUIDE
CD229/2307075
Note:TheEstopboardisusedforconnectingpowertothesystem
eveniftheEstopfunctionisnotbeingused.
1TB–UserConnectionforOSD1and2
1TB1 InternalConnection,DoNotUse
(+24VDC)
1TB2 InternalConnection,DoNotUse
(Ground)
1TB3 InternalConnection,DoNotUse
(0V)
1TB4 InternalConnection,DoNotUse
(KeyA)
1TB5 InternalConnection,DoNotUse
(KeyB)
1TB6 InternalConnection,DoNotUse
(COMnotused)
1TB7 InternalConnection,DoNotUse
(RUN,RedLEDindicator)
1TB8 InternalConnection,DoNotUse
(WAIT,YellowLEDindicator)
1TB9 InternalConnection,DoNotUse
(ENTER,GreenLEDindicator)
1TB10 OSD1–OutputSwitchingDeviceProvidethefailsafeoutputs
forconnectiontothemachinecontrolsystem.Connectterminals1TB10and
1TB11toonechannelofthemachine’sstopcircuitry.Outputsarevoltage
freecontacts. Maximumswitchingcurrentis1Aat 110VAC
1TB11 OSD1–(see1TB10)
1TB12 OSD2–OutputSwitchingDeviceProvidethefailsafeoutputs
forconnectiontothemachinecontrolsystem.Connectterminals1TB12and
1TB13toonechannelofthemachine’sstopcircuitry.Outputsarevoltage
freecontacts. Maximumswitchingcurrentis1Aat 110VAC
1TB13 OSD2–(see1TB12)