SMARTZO KJ180F-E02 Bedienungsanleitung

E02 Air Purifier User manual

2
Welcome
Dear Customer,
Congratulations on your purchase of the Smartzo E02 Air Purifier.
This product is meticulously designed with high-quality materials and
components.
Please read the user manual carefully to familiarize yourself with the unique
features and functions of the air purifier. Please store this manual in a safe
place for future reference.
Welkom
Beste klant,
Gefeliciteerd met de aankoop van de Smartzo E02 Luchtreiniger.
Dit product is ontworpen en gemaakt met hoge kwaliteitsmaterialen en
onderdelen.
Lees de gebruikershandleiding aandachtig door om vertrouwd te raken met
de speciale kenmerken en functies van de luchtreiniger. Bewaar de
gebruikshandleing op een veilige plaats voor toekomstig gebruik.

3
English
Key Features
•High airflow rate: 180m3per hour.
•Very low noise:
oMin. 25dB.
oMax. 56dB
•Fashion statement: elegant and cosy, creating a favourable environment
for your bedroom and office.
•Effective and cleaner: excellent air flow rate and HEPA filter make your
room free from dust and odour.
•Energy-efficient and sage: Brushless DC motor, low-voltage DC, Max
power consumption < 22W
Caution
•Use only the original power adapter; in case the adapter or wire is
damaged, please get in touch with the Smartzo customer care at
•Do not touch the electrical plug with wet hands.
•Disconnect the power supply before replacing the filter or if the product
is not used for an extended period.
•Ensure the power supply is as per the voltage indicated on the adapter,
i.e. 220V/50Hz.
•Do not put any object inside the air purifier either from the inlet or
outlet.
•Do not block the inlet or the outlet of the air purifier.
•Do not attempt to repair or dismantle the air purifier; this needs to be
done only by authorized service personnel.
•Keep the air purifier away from water, heat and fire.
•Do not run the air purifier without the filter. The suction of dust may
cause problems in the equipment and its components.

4
Components
Control panel
Air outlet
Air inlet (360°)
Air quality indicator light
PM2.5 Sensor cover
Power switch
Power input

5
Rotate to open
Components
HEPA Filter
UV Lamp
Getting started
1. Turn upside down the equipment after unpacking it.
2. Rotate the base cover to take out the filter by the guide arrow.
3. Replace the filter after removing the packing. Take care to rotate the
base cover in the reverse direction described in step 2.
4. Attach the power adapter to the power input.
5. Keep the air purifier on a dry, stable and firm surface in a straight
position.
6. Insert the power adapter of the air purifier into the main power supply.
7. Press the [POWER] button. The air purifier turns on now.

6
Control Panel
How to use
Start:
After the main power is switched on, press the [POWER] button. The air
quality indicator lamp will light up. It will run in AUTO mode.
Auto mode:
Press the [AUTO] button when the air purifier is in another mode to set the
air purifier in the auto mode.
The auto indicator will glow in the auto mode, and the air purifier
automatically adjusts the airflow depending on the indoor air quality. The air
quality indicator lamp will glow to the corresponding level of air quality.
Colour of the Ring
Blue
Amber
Purple
Red
Air quality
Good
Moderate
Polluted
Bad

7
Sleep mode:
Press the [SLEEP] button after the start or in the other mode, and it will go
into sleep mode. The sleep indicator will light in the sleep mode, and the air
purifier will run at speed 1 or 2.
Manual mode:
Press the [AIR FLOW] button after the start or in the other mode, and it will
go into the manual mode. The corresponding speed indicator will light in the
manual mode, and the air purifier will run at the selected speed. You can
change the speed by pressing the airflow selector button.
Timer function:
Press the [TIMER] button after the start or in the other mode, and it will go
into the timer mode.
In the timer mode, it is possible to set the specific time between 0.5-24hrs to
switch off the air purifier automatically. The set time will be indicated on
display.
Light control function:
Press the [LIGHT] button to switch ON/OFF the air quality light and airflow
indicator. This function can be used during the night when you do not want
any light to disturb your sleep.
Ions function:
Press the [IONS] button after startup or in other modes. The indicator will
light while the anion generator releases anions.
Press the [IONS] button again to stop releasing anions. Also, the light turns
off.
UV Lamp function:
Press the [UV] button after startup or while in other modes to turn the UV
LED light on. Press the [UV] button again to stop the function and turn the UV
LED light off.

8
Stop function:
If you want to switch off the air purifier completely, press the [Power]
button, the air purifier will switch off, and all lights will be off.
PM2.5 Indicator function:
After starting up, the PM2.5 indication will flow twinkle. Thirty (30) seconds
later, the air purifier will show the detected value of PM2.5 by the sensor.
Notice: This function is for home use and is not used as a professional
instrument.
Filter reset button function:
Press this button when starting up, the button lamp light and display will
show the residual life of the filter in percentages (“%”). After three seconds,
it will the filter life percentage will disappear.
When the filter needs to be replaced, the light at the top of the button lights
up. After the filter is replaced, please press this button for 5 seconds to reset
it.
Maintenance
Before attempting to perform any maintenance on the air purifier,
disconnect the power adapter.
Filter
Suggested time of changing the filter: about once a year.
•It depends on the location the air purifier is placed. For example, the
filter life is shortened in contaminated zones or smoking areas, etc.
•Change the filter if the purification effect is not good.
Cleanup routines: biweekly
•Use a soft brush or dry cotton cloth to clean the filter surface only.
•Do not use water to wash the filter.
•Do not force press or pull because the filter can be broken or deformed
easily. Change the filter before using, if it is damaged.

9
Sensor Cleaning
Notice
1. Keep the surface of the sensor clean, or sensitivity is affected and could
even fail to work.
2. Recommended cleaning cycle is less than 1 month for regularly used.
3. Clean the sensor with a cotton swab, as shown in the picture below.
Do not use detergent or any liquid in the cleaning process.
Cylinder inner surface cleaning
External surface
Use a soft dry fabric to wipe the surface, inlets and outlets.
•Do not use any chemical cleaning products.
During long unuse
•Unplug the unit from the power socket.
•Clean the surface and filter.
•Store at a dry and cool place and cover it with a plastic bag.