SETTINGTORQUEFORVALVEOPERATION(OPENING)
Ensurethedirectionselectorswitch(D)issettoreverse
Setthetorquetomaximum
oTheSFC‐EDEElectricTorqueToolcomeswithatorquecalibrationcertificate.Thetorque
calibrationcertificatedisplaysalphaandnumericcharactersthataredialledinonthetool
thatcorrespondtothetorquevaluestotheright.Toselectadesiredtorque,dialinyour
SFC‐EDEbyusingthealphaandnumericselectors(E)onthetopoftheSFC‐EDE.
oForthe“SampleSFC‐EDETorqueCalibrationCertificate”shownabovethemaximum
torqueisG,4
6. OPERATINGTHETORQUETOOL
1) Fitthetoolintotheuniversal,‘bolt‐on’,handwheeldriveplate.
2) MovetheDirectionSelectorSwitch(D)fromtheneutralpositionandintoeitherforwardor
reverseasrequired.
3) SqueezethesoftstartTrigger(C)toactivatethetoolandapplythetorque.
4) FullypressthesoftstartTrigger(C)andkeeppresseduntilthetoolstalls.Ifthetriggerisreleased
beforethetorquetoolstalls,fulltorquewillnotbeappliedtothevalve.Oncethemotorstallsdo
not“blip”thetrigger,orincorrecttorquewillbeapplied.
5) Inuse,thetorquetoolmustbesupportedatalltimes.
6) Ifavalvewillnotoperatewhenthetoolissettomaximumonthecalibrationcertificate,donot
“blip”thetriggerrepeatedly,andusetoolingofhighertorqueoutput.
7) Removetoolfromvalve.
IMPORTANT:Ifbreakdown,malfunctionordamageoccursdonotattempttorepair,contactSmithFlow
ControlLimited
7) MAINTENANCEANDRECALIBRATION
Topreventprematurefailureandensureconfidenceintorquesupply,itisrecommendedthatthis
equipmentisservicedandcalibratedatleastonanannualbasis.
WARRANTY
SFC‐EDEcomeswithaoneyear(1)conditionalwarranty.
SFC‐EDEisguaranteedagainstmanufacturerandmaterialdefects,butnotagainstabuse,misuseor
neglectbytheuser.TheSquareDriveisanonwarrantyitem.