Sole Digital HNG100 Bedienungsanleitung

© CASWA Pty Ltd –2014 1 | Page
HOISTNET GATEWAY
Model HNG100, Version 1+
Installation and User Manual
Revision 02 –December 2018
© CASWA Pty Ltd –2014

© CASWA Pty Ltd –2014 2 | Page
CONTENTS
1OVERVIEW............................................................................................................................3
2SPECIFICATIONS....................................................................................................................3
2.1 Physical Specifications ............................................................................................................3
2.2 Electrical Specifications...........................................................................................................4
2.3 Communication Specifications................................................................................................4
3INSTALLATION DETAILS.........................................................................................................5
3.1 Prior to Installation .................................................................................................................5
3.2 Wiring Diagrams......................................................................................................................6
3.2.1 Using Analog Outputs ..............................................................................................6
3.2.2 Connecting RS485 Outputs ......................................................................................7
4COMMISSIONING DETAILS ....................................................................................................7
4.1 Installing and Launching the FSU Application.........................................................................7
4.1.1 FSU Program Installation..........................................................................................7
4.1.2 Installing the FSU application...................................................................................8
4.1.3 Launching the application........................................................................................8
4.2 Connecting to the Device........................................................................................................8
4.3 Checking for Firmware............................................................................................................9
4.4 HoistNet GateWay Configuration Screen .............................................................................11
4.4.1 Setting the ID..........................................................................................................11
4.4.2 Setting/Changing the HoistNet Inputs ...................................................................11
4.5 Configuring Analog Outputs..................................................................................................13
4.6 Configuring RS485 Outputs...................................................................................................13
5ROUTINE MAINTENANCE .................................................................................................... 14
6TROUBLESHOOTING............................................................................................................ 14
APPENDIX A: FSU SYSTEM REQUIREMENTS................................................................................. 15

© CASWA Pty Ltd –2014 3 | Page
1OVERVIEW
The HoistNet GateWay is a device for receiving up to two signals from other HoistNet devices and
outputting the load via two fully isolated sinking or sourcing 4-20mA channels and/or a
programmable RS485 serial interface.
2SPECIFICATIONS
2.1 Physical Specifications
Overall length (mm):
115
Overall width (mm):
100
Overall height (mm):
23
Weight (kg):
0.12
Mounting:
30mm DIN Rail
Figure 1: Case Dimensions

© CASWA Pty Ltd –2014 4 | Page
2.2 Electrical Specifications
Parameter
Description
Min
Typ
Max
Units
Vin
Supply voltage
24
250
VAC
Iin
Supply current
7
8
12
mA
Aimin
Analogue channel minimum output current
3
3.5
4
mA
Aimax
Analogue channel maximum output current
22
25
28
mA
Visolate
Isolation on analog and digital outputs
2000
V
Vheadroom
Voltage drop across analog output
3
5
8
VDC
Allowable operating temperature
-25
85Note1
°C
Note1: Extended operation at maximum temperature will reduce the life the device.
2.3 Communication Specifications
Communications between the device and a host is usually via a Bluetooth radio link. The Bluetooth
device name will be set to the Crane ID, the PIN is 0000.
For more details on the communication protocol used to communicate with the HoistNet GateWay,
contact support@caswa.com.

© CASWA Pty Ltd –2014 5 | Page
3INSTALLATION DETAILS
3.1 Prior to Installation
Before installing your HoistNet GateWay unit visually inspect the device and check that:
(a) the type of input marked on the front of the device is appropriate for your application;
(b) the case is not damaged and fits together securely;
(c) terminals are secure;
(d) terminal numbering is as per the following diagram.
NB: As each block of 4 terminals can be removed (for installation) it is important that they be
reinstalled in the positions shown.
Terminal
Function
Notes
1
0V
2
24-240V AC/DC
3
Tare 1
Connect to 0V to tare
4
Tare 2
5
4-20mA - (Chan 2)
6
No Connection
7
4-20mA + (Chan 2)
8
No Connection
9
4-20mA - (Chan 1)
10
4-2mA + (Chan 1)
11
RS485 Gnd
Isolated from
12
No Connection
13
A
14
B
15
Z
16
Y
Figure 2: Terminal Positions

© CASWA Pty Ltd –2014 6 | Page
3.2 Wiring Diagrams
3.2.1 Using Analog Outputs
The Analog Outputs are fully isolated and can be wired up as either sourcing (See Figure 3) or sinking
outputs (See Figure 4).
Figure 3: Connecting the Analog Outputs as Sourcing Outputs
Figure 4: Connecting the Analog Outputs as Sinking Outputs

© CASWA Pty Ltd –2014 7 | Page
3.2.2 Connecting RS485 Outputs
Connect output RS485 terminals, marked Y and Z, on the HoistNet Gateway (terminals 16 and 15
respectively) to inputs A and B on the receiving device.
Note: Terminals 13 and 14 marked as A and B on the HoistNet GateWay are RS485 inputs.
Figure 5: Example of connecting the HoistNet GateWay to a RS485 receiver.
4COMMISSIONING DETAILS
HoistNet GateWay is designed to be commissioned using a laptop computer. You will need a CASWA
LINK-2 Bluetooth Modem and the Field Service Utility (FSU) software application loaded on a laptop.
4.1 Installing and Launching the FSU Application
4.1.1 FSU Program Installation
Ensure that your computer is switched on, connected to the internet and that the minimum required
software versions are installed (see Appendix A for minimum system requirements). Ensure that the
LINK-2 modem is installed and that the drivers have loaded.

© CASWA Pty Ltd –2014 8 | Page
4.1.2 Installing the FSU application
The latest FSU software can be downloaded from the following link and should be checked
periodically for updates: http://www.soledigital.com.au/Link2.html
4.1.3 Launching the application
Double click on the FSU program icon:
4.2 Connecting to the Device
The FSU will scan for Bluetooth enabled devices. This process takes approximately 10 seconds, when
complete a list of all Sole Digital devices within range will be displayed.
The HoistNet GateWay icon looks like this:
If the desired HoistNet GateWay unit is not found, ensure it is powered up and press to repeat
the search.
NB: The Bluetooth link between the Laptop using a Link-2 and a HoistNet GateWay has a range of
approximately 200m.

© CASWA Pty Ltd –2014 9 | Page
Double click the HoistNet GateWay you wish to configure to establish a connection.
4.3 Checking for Firmware
To check the current firmware of the Hoistnet Gateway, right click on the Hoistnet Gateway Icon
within the FSU discovery screen and choose <manage firmware>.
A new window will open. The FSU will establish a connection, check what version of firmware is
currently on the HoistNet GateWay and show you a selection of newer versions of firmware that are
available. If there are no new firmware versions available there will be no selections available to
pick.

© CASWA Pty Ltd –2014 10 | Page
When you pick the firmware you want to update the Hoistnet GateWay the <Apply Firmware>
button becomes visible. Click the <Apply Firmware> button to begin the firmware update.
A progress bar will begin showing how far along the firmware update is. When its complete it will
show a pop up message.
DO NOT switch off the computer or remove the LINK2 modem until this is complete –doing so
may leave the HoistNet GateWay in an unrecoverable state.
Inhaltsverzeichnis
Andere Sole Digital Tor Handbücher
Beliebte Tor Handbücher anderer Marken

LST
LST M500RFE-AS Bedienungsanleitung

Kinnex
Kinnex Media Gateway Bedienungsanleitung

2N Telekomunikace
2N Telekomunikace 2N StarGate Bedienungsanleitung

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries Superlink SC-WBGW256 Bedienungsanleitung

ZyXEL Communications
ZyXEL Communications ZYWALL2 ET 2WE Bedienungsanleitung

Telsey
Telsey CPVA 500 - SIP Bedienungsanleitung